Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; : e14476, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39031856

RESUMEN

OBJECTIVE: An accurate measurement of x-ray beams is expected to reduce the uncertainties associated with estimating radiation risk to patients in clinical settings. To perform assessment tasks based on the readings of a solid-state detector (SSD) using semiconductor technology, the characteristics of the detector should be elucidated. In this study, we evaluated the measurement accuracy of a new SSD under diagnostic x-ray beam conditions in terms of air kerma, tube voltage, and half-value layer (HVL). The performance of the SSD was then compared with those of reference instruments. METHODS: The tube voltage was varied within the range of 50-120 kV in steps of 10 kV and the thickness and materials of additional filters were concurrently changed (several combinations were tested). In addition, the dose rate and energy dependence of the SSD were also investigated. These effects were analyzed based on statistical significance tests. Furthermore, the expanded uncertainties in the series of measurements were meticulously calculated. RESULTS: The results showed average relative differences of -3.26 ± 1.33%, 0.44 ± 1.01%, and -2.60 ± 3.31% for air kerma, tube voltage, and HVL, respectively. Furthermore, air kerma did not exhibit any dependence on dose rate and energy, in contrast to tube voltage and HVL measurements. CONCLUSION: The measurement values of the SSD fall within the acceptable range of uncertainty, highlighting its measurement accuracy and reliability. Furthermore, based on the characteristics elucidated by this study, valuable insights are provided concerning the assurance of appropriate measurement values in clinical settings.

2.
J Xray Sci Technol ; 32(3): 569-581, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38217636

RESUMEN

PURPOSE: To compare image quality, iodine intake, and radiation dose in overweight and obese patients undergoing abdominal computed tomography (CT) enhancement using different scanning modes and contrast medium. METHODS: Ninety overweight and obese patients (25 kg/m2≤body mass index (BMI)< 30 kg/m2 and BMI≥30 kg/m2) who underwent abdominal CT-enhanced examinations were randomized into three groups (A, B, and C) of 30 each and scanned using gemstone spectral imaging (GSI) +320 mgI/ml, 100 kVp + 370 mgI/ml, and 120 kVp + 370 mgI/ml, respectively. Reconstruct monochromatic energy images of group A at 50-70 keV (5 keV interval). The iodine intake and radiation dose of each group were recorded and calculated. The CT values, contrast-to-noise ratios (CNRs), and subjective scores of each subgroup image in group A versus images in groups B and C were by using one-way analysis of variance or Kruskal-Wallis H test, and the optimal keV of group A was selected. RESULTS: The dual-phase CT values and CNRs of each part in group A were higher than or similar to those in groups B and C at 50-60 keV, and similar to or lower than those in groups B and C at 65 keV and 70 keV. The subjective scores of the dual-phase images in group A were lower than those of groups B and C at 50 keV and 55 keV, whereas no significant difference was seen at 60-70 keV. Compared to groups B and C, the iodine intake in group A decreased by 12.5% and 13.3%, respectively. The effective doses in groups A and B were 24.7% and 25.8% lower than those in group C, respectively. CONCLUSION: GSI +320 mgI/ml for abdominal CT-enhanced in overweight patients satisfies image quality while reducing iodine intake and radiation dose, and the optimal keV was 60 keV.


Asunto(s)
Medios de Contraste , Obesidad , Sobrepeso , Radiografía Abdominal , Tomografía Computarizada por Rayos X , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad/diagnóstico por imagen , Sobrepeso/diagnóstico por imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más Años
3.
Acta Radiol ; 64(3): 1047-1055, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35912446

RESUMEN

BACKGROUND: Contrast-induced nephropathy (CIN) is an adverse reaction associated with the use of intravenous contrast media (CM). PURPOSE: To investigate the impact of low tube voltage settings on single-energy computed tomography (SECT) and rapid kV switching dual-energy CT (DECT) with reduced concentrations of iodinated CM. MATERIAL AND METHODS: A phantom containing four different concentrations of CM (original concentration CM, 20%, 40%, and 60% reductions) was scanned using SECT mode with varying tube voltages (70, 80, 100, and 120 kVp) and DECT mode through reconstructing monoenergetic energy (50 keV and 70 keV) images. ATCM system with different noise index (NI) settings were set, and the images were reconstructed using ASiR-V. Image quality were measured for individual phantom sizes and protocols and compared to a reference protocol for SECT of 120 kVp, NI = 18, threshold contrast enhancement ≥280 HU, and CNR ≥17. RESULTS: Tube voltage settings of 70 kVp together with 40% reduction in the iodinated CM is suitable for small phantom size, those of 80 kVp and 20% reduction is suitable for the medium and large sizes. This allows radiation doses to be reduced by 12%-30%. Values of CNR and contrast for DECT are better than those for SECT with the same NI setting. CONCLUSION: Diagnostic reference of image quality can be maintained by using SECT with lower tube voltage and DECT with reductions of iodinated CM concentration and radiation dose. Therefore, the NI setting can be increased when DECT is used to achieve a similar image quality.


Asunto(s)
Medios de Contraste , Tomografía Computarizada por Rayos X , Humanos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Dosis de Radiación
4.
Eur Radiol ; 32(11): 7700-7709, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35441839

RESUMEN

OBJECTIVES: The aim of this study was to compare the quality of images obtained using single-energy computed tomography (SECT) performed with automated tube voltage adaptation (TVA) with dual-energy CT (DECT) weighted average images. METHODS: Eighty patients were prospectively randomized to undergo either SECT with TVA (n = 40, ref. mAs 200) or radiation dose-matched DECT (n = 40, 80/Sn150 kV, ref. mAs tube A 91/tube B 61) on a dual-source CT scanner. Objective image quality was evaluated as dose-normalized contrast-to-noise ratio (CNRD) for the jugular veins relative to fatty tissue and muscle tissue and for muscle tissue relative to fatty issue. For subjective image quality, reproduction of anatomical structures, image artifacts, image noise, spatial resolution, and overall diagnostic acceptability were evaluated at sixteen anatomical substructures using Likert-type scales. RESULTS: Effective radiation dose (ED) was comparable between SECT and DECT study groups (2.9 ± 0.6 mSv/3.1 ± 0.7 mSv, p = 0.5). All examinations were rated as excellent or good for clinical diagnosis. Compared to the CNRD in the SECT group, the CNRD in the DECT group was significantly higher for the jugular veins relative to fatty tissue (7.51/6.08, p < 0.001) and for muscle tissue relative to fatty tissue (4.18/2.90, p < 0.001). The CNRD for the jugular veins relative to muscle tissue (3.33/3.18, p = 0.51) was comparable between groups. Image artifacts were less pronounced and overall diagnostic acceptability was higher in the DECT group (all p = 0.01). CONCLUSIONS: DECT weighted average images deliver higher objective and subjective image quality than SECT performed with TVA in head and neck imaging. KEY POINTS: • Weighted average images derived from dual-energy CT deliver higher objective and subjective image quality than single-energy CT using automated tube voltage adaptation in head and neck imaging. • If available, dual-energy CT acquisition may be preferred over automated low tube voltage adopted single-energy CT for both malignant and non-malignant conditions.


Asunto(s)
Cabeza , Tomografía Computarizada por Rayos X , Humanos , Dosis de Radiación , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Cabeza/diagnóstico por imagen , Cuello
5.
BMC Cardiovasc Disord ; 22(1): 545, 2022 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-36513994

RESUMEN

BACKGROUND: This study investigated accuracy and consistency of epicardial adipose tissue (EAT) quantification in non-ECG-gated chest computed tomography (CT) scans. METHODS: EAT volume was semi-automatically quantified using a standard Hounsfield unit threshold (- 190, - 30) in three independent cohorts: (1) Cohort 1 (N = 49): paired 120 kVp ECG-gated cardiac non-contrast CT (NCCT) and 120 kVp non-ECG-gated chest NCCT; (2) Cohort 2 (N = 34): paired 120 kVp cardiac NCCT and 100 kVp non-ECG-gated chest NCCT; (3) Cohort 3 (N = 32): paired non-ECG-gated chest NCCT and chest contrast-enhanced CT (CECT) datasets (including arterial phase and venous phase). Images were reconstructed with the slice thicknesses of 1.25 mm and 5 mm in the chest CT datasets, and 3 mm in the cardiac NCCT datasets. RESULTS: In Cohort 1, the chest NCCT-1.25 mm EAT volume was similar to the cardiac NCCT EAT volume, while chest NCCT-5 mm underestimated the EAT volume by 7.5%. In Cohort 2, 100 kVp chest NCCT-1.25 mm were 13.2% larger than 120 kVp cardiac NCCT EAT volumes. In Cohort 3, the chest arterial CECT and venous CECT dataset underestimated EAT volumes by ~ 28% and ~ 18%, relative to chest NCCT datasets. All chest CT-derived EAT volumes were similarly associated with significant coronary atherosclerosis with cardiac CT counterparts. CONCLUSION: The 120 kVp non-ECG-gated chest NCCT-1.25 mm images produced EAT volumes comparable to cardiac NCCT. Chest CT EAT volumes derived from consistent imaging settings are excellent alternatives to the cardiac NCCT to investigate their association with coronary artery disease.


Asunto(s)
Enfermedad de la Arteria Coronaria , Pericardio , Humanos , Pericardio/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Tejido Adiposo/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Cintigrafía , Angiografía Coronaria/métodos
6.
Acta Radiol ; 63(4): 458-466, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33709794

RESUMEN

BACKGROUND: The low-tube-voltage scan generally needs a higher tube current than the conventional 120 kVp to maintain the image noise. In addition, the low-tube-voltage scan increases the photoelectric effect, which increases the radiation absorption in organs. PURPOSE: To compare the organ radiation dose caused by iodine contrast medium between low tube voltage with low contrast medium and that of conventional 120-kVp protocol with standard contrast medium. MATERIAL AND METHODS: After the propensity-matching analysis, 66 patients were enrolled including 33 patients with 120 kVp and 600 mgI/kg and 33 patients with 80 kVp and 300 mgI/kg (50% iodine reduction). The pre- and post-contrast phases were assessed in all patients. The Monte Carlo simulation tool was used to simulate the radiation dose. The computed tomography (CT) numbers for 10 organs and the organ doses were measured. The organ doses were normalized by the volume CT dose index, and the 120-kVp protocol was compared with the 80-kVp protocol. RESULTS: On contrast-enhanced CT, there were no significant differences in the mean CT numbers of the organs between 80-kVp and 120-kVp protocols except for the pancreas, kidneys, and small intestine. The normalized organ doses at 80 kVp were significantly lower than those of 120 kVp in all organs (e.g. liver, 1.6 vs. 1.9; pancreas, 1.5 vs. 1.8; spleen, 1.7 vs. 2.0) on contrast-enhanced CT. CONCLUSION: The low tube voltage with low-contrast-medium protocol significantly reduces organ doses at the same volume CT dose index setting compared with conventional 120-kVp protocol with standard contrast medium on contrast-enhanced CT.


Asunto(s)
Medios de Contraste , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Imagen de Cuerpo Entero/instrumentación , Imagen de Cuerpo Entero/métodos , Adulto , Femenino , Humanos , Yodo , Masculino , Persona de Mediana Edad
7.
Circ J ; 85(4): 369-376, 2021 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-33441495

RESUMEN

BACKGROUND: Low tube voltage computed tomography venography (CTV) can be expected to increase imaging contrast and decrease radiation exposure by using iterative reconstruction (IR). This study evaluated the diagnostic ability of low tube voltage CTV with IR for deep vein thrombosis (DVT), compared to ultrasonography (US).Methods and Results:Two experienced radiologists retrospectively reevaluated the CTV data of 55 of 318 consecutive patients suspected of having DVT or pulmonary embolism between December 2015 and April 2017. The 55 patients had undergone both low tube voltage CTV and US (within 1 day before or after CTV). The lower extremity veins were divided into 10 segments. The DVT forms were categorized into 3 types: complete, concentric, and eccentric. We analyzed the 534 overall segments (16 segments excluded in US) measured using both CTV and US. The sensitivity-specificity was overall 73.3-90.0%, for femoropopliteal, it was 90.0-93.2%, and for the calf, it was 71.1-87.2%. The diagnostic accuracy between the 'eccentric only' and 'others' groups focusing on DVT forms was compared, and significant differences were revealed, especially in the muscular vein. CONCLUSIONS: The DVT diagnostic ability above the knee was comparable between low tube voltage CTV with IR and conventional CTV, and the radiation dose was reduced. It was suggested that eccentric DVT measured by CTV tend to be a false-positive, especially in the calf muscular vein.


Asunto(s)
Extremidad Inferior/diagnóstico por imagen , Trombosis de la Vena , Humanos , Extremidad Inferior/patología , Flebografía , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Ultrasonografía , Trombosis de la Vena/diagnóstico por imagen
8.
J Appl Clin Med Phys ; 22(2): 178-184, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33449434

RESUMEN

This study aimed to compare the dose and noise level of four tube voltages in abdominal computerized tomography (CT) examinations in different abdominal circumference sizes of pregnant women. Fetal radiation doses were measured with two anthropomorphic pregnant phantoms and real-time dosimeters of photoluminescence sensors using four tube voltages for abdominal CT. The noise level was measured at the abdomen of two anthropomorphic pregnant phantoms. In the large pregnant phantom, the mean fetal doses performed using 120 and 135 kV were statistically significantly lower than the lower tube voltages (P < 0.05). In the small pregnant phantom, the mean fetal dose performed by 100, 120, and 135 kV was significantly lower than the lowest tube voltage tested (P < 0.05). The ratios of the peripheral mean dose to the centric mean dose showed that the ratios of 80 kV were the highest and those for 135 kV were the lowest in both pregnant phantoms. The ratios of the peripheral mean dose to the centric mean dose decreased as the tube voltage increased. Compared with low tube voltages, high tube voltages such as 120 and 135 kV could reduce radiation doses to the fetus without compromising the image uniformity in abdominal CT examinations during pregnancy. On low tube voltage protocols, the dose near the maternal skin surface may be increased in large pregnant women because of reduced penetration of the x rays.


Asunto(s)
Abdomen , Tomografía Computarizada por Rayos X , Abdomen/diagnóstico por imagen , Femenino , Feto , Humanos , Fantasmas de Imagen , Embarazo , Dosis de Radiación
9.
J Xray Sci Technol ; 29(4): 687-695, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34092694

RESUMEN

OBJECTIVE: To investigate feasibility of applying deep learning image reconstruction (DLIR) algorithm in a low-kilovolt enhanced scan of the upper abdomen. METHODS: A total of 64 patients (BMI<28) are selected for the enhanced upper abdomen scan and divided evenly into two groups. The tube voltages in Group A are 100kV in arterial phase and 80kV in venous phase, while tube voltages are 120kV during two phases in Group B. Image reconstruction algorithms used in Group A include the filtered back projection (FBP) algorithm, the adaptive statistical iterative reconstruction-Veo (ASIR-V 40% and 80%) algorithm, and the DLIR algorithm (DL-L, DL-M, DL-H). Image reconstruction algorithm used in Group B is ASIR-V40%. The different reconstruction algorithm images are used to measure the common hepatic artery, liver, renal cortex, erector spinae, and subcutaneous adipose in the arterial phase and the average CT value and standard deviation of the portal vein, liver, spleen, erector spinae, and subcutaneous adipose in the portal phase. The signal-to-noise ratio (SNR) is calculated, and the images are also scored subjectively. RESULTS: In Group A, noise in the aorta, liver, portal vein (the portal phase), spleen (the portal phase), renal cortex, retroperitoneal adipose, and muscle is significantly lower in both the DL-H and ASIR-V80% images, and the SNR is significantly higher than those in the remaining groups (P<0.05). The SNR of each tissue and organ in Group B is not significantly different from that in DL-M, DL-L, and ASIR-V40% in Group A (P>0.05). The subjective image quality scores in the DL-H and B groups are higher than those in the other groups, and the FBP group has significantly lower image quality than the remaining groups (P<0.05). CONCLUSION: For upper abdominal low-kilovolt enhanced scan data, the DLIR-H gear yields a more satisfactory image quality than the FBP and ASIR-V.


Asunto(s)
Aprendizaje Profundo , Abdomen/diagnóstico por imagen , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
10.
Breast Cancer Res Treat ; 184(3): 817-823, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32910319

RESUMEN

PURPOSE: To evaluate the detectability of breast cancer and visibility of the tumor extent using 70-kV single-energy contrast-enhanced (CE) breast computed tomography (70-kV CECT) compared with CE breast magnetic resonance imaging (CEMR). METHODS: Between 2013 and 2015, 110 patients with 112 breast cancer lesions who underwent breast surgery after undergoing both 70-kV CECT and CEMR were enrolled. The major axis lengths of the breast lesion were measured and compared with the pathologically determined major axes. Agreement in the measured major axes was evaluated using the intra-class correlation coefficient (ICC). RESULTS: Both 70-kV CECT and CEMR depicted all breast cancer lesions. The mean major axis was 3.0 (95% confidence interval [CI], 2.5-3.4) cm on CECT and 2.9 (2.6-3.3) cm on CEMR. The mean differences between the pathologically and radiologically measured major axes on 70-kV CECT and CEMR were 0.9 (0.7-1.1) and 1.0 (0.8-1.2) cm, respectively. The accuracy of the radiological major axes compared with the pathological major axes was 82.1% and 80.4% on CECT and CEMR, respectively (p = 0.81). The major axes on the two modalities demonstrated moderate agreement (ICC = 0.69, 95% CI 0.58-0.77). Pathologically and radiologically measured major axes on 70-kV CECT and CEMR demonstrated excellent agreement (ICC = 0.91, 95% CI 0.93-0.96). CONCLUSIONS: Low-tube voltage (70-kV) CECT is the preferred modality to identify breast cancer lesions and tumor extent for preoperative planning because it has a similar diagnostic ability to CEMR and can be performed in the supine position.


Asunto(s)
Neoplasias de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Medios de Contraste , Femenino , Humanos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X
11.
Circ J ; 84(4): 601-608, 2020 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-32074543

RESUMEN

BACKGROUND: Although coronary computed tomography angiography (CTA) is frequently used for identifying coronary artery disease, no studies have investigated the radiation dose in detail in Japan. The aim of this study was to estimate the radiation dose of coronary CTA in Japanese clinical practice and to identify the independent predictors associated with radiation dose.Methods and Results:A multicenter, retrospective, observational study (54 institutions) was conducted for estimating the radiation dose of coronary CTA in 2,469 patients between January and December 2013. Independent predictors associated with radiation dose were investigated on linear regression analysis. Median dose-length product (DLP) was 809.0 mGy·cm (IQR, 350.0-1,368.8 mGy·cm), corresponding to an estimated radiation dose of 11 mSv. The DLP per site significantly differed between institutions (median DLP per site, 92-2,131 mGy·cm; P<0.05). Independent predictors associated with radiation dose on multivariable linear regression were body weight, heart rate, non-stable sinus rhythm, scan length, tube voltage setting, electrocardiogram (ECG)-gated scanning protocol, and the image reconstruction technique (P<0.05 each). CONCLUSIONS: The coronary CTA radiation dose was relatively high in 2013, and it varied significantly between institutions. Effective strategies for radiation dose reduction were low tube voltage ≤100 kVp, retrospective ECG-gated scanning with dose modulation technique, prospective ECG-gated scanning, and the iterative reconstruction technique.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada Multidetector , Dosis de Radiación , Exposición a la Radiación , Anciano , Técnicas de Imagen Sincronizada Cardíacas , Angiografía por Tomografía Computarizada/efectos adversos , Angiografía Coronaria/efectos adversos , Electrocardiografía , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/efectos adversos , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Sistema de Registros , Estudios Retrospectivos
12.
Emerg Radiol ; 27(2): 135-140, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31773437

RESUMEN

PURPOSE: Evaluate the potential effects of X-ray tube voltage (kV) changes on Hounsfield unit (HU) measurements of hemoperitoneum in patients with blunt splenic injuries. METHODS: Eight different tissue equivalent electron density plugs in the Electron Density Phantom were scanned (muscle, adipose, breast, liver, lung (exhale), lung (inhale), trabecular bone, and dense bone). The phantom was scanned at different kV values (70, 80, 100, 120, and 140 kV). In the clinical study, the local trauma registry database was queried for splenic injuries between January 2015 and December 2016 with a final cohort of 110 patients. The average HU numbers of hemoperitoneum found in three different anatomic locations (pelvic, perisplenic, and perihepatic) were compared at different kV values (100 kV, 120 kV, and 140 kV). ANOVA and pairwise t tests were performed for statistical analysis. RESULTS: In both studies, HU measurements generally decreased as kV increased, and vice versa. One hundred ten patients were reviewed: 29 for 100 kV, 66 for 120 kV, and 15 for 140 kV. For the perihepatic group, significant differences were observed in average HU in the following pairwise comparisons: 100/140 (13.7 (5.3), p < 0.05) and 120/140 (10.3 (4.5), p < 0.05). For the perisplenic group, significant differences were observed in 100/120 (7.0 (3.5), p < 0.05) and 100/140 (13.2 (4.9), p < 0.05). No significant difference was observed in the pelvic location (p = 0.5594). CONCLUSIONS: HU measurements of hemoperitoneum in patients with blunt splenic injuries significantly varied with the use of different kV values. Radiologists should be aware of the possible effects of altering kV on HU.


Asunto(s)
Hemoperitoneo/diagnóstico por imagen , Radiografía Abdominal/métodos , Bazo/lesiones , Tomografía Computarizada por Rayos X/métodos , Heridas no Penetrantes/diagnóstico por imagen , Femenino , Humanos , Masculino , Fantasmas de Imagen , Dosis de Radiación , Estudios Retrospectivos
13.
AJR Am J Roentgenol ; 213(2): 325-331, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31039021

RESUMEN

OBJECTIVE. Coronary CT angiography (CCTA)-based methods allow noninvasive estimation of fractional flow reserve (cFFR), recently through use of a machine learning (ML) algorithm (cFFRML). However, attenuation values vary according to the tube voltage used, and it has not been shown whether this significantly affects the diagnostic performance of cFFR and cFFRML. Therefore, the purpose of this study is to retrospectively evaluate the effect of tube voltage on the diagnostic performance of cFFRML. MATERIALS AND METHODS. A total of 525 coronary vessels in 351 patients identified in the MACHINE consortium registry were evaluated in terms of invasively measured FFR and cFFRML. CCTA examinations were performed with a tube voltage of 80, 100, or 120 kVp. For each tube voltage value, correlation (assessed by Spearman rank correlation coefficient), agreement (evaluated by intraclass correlation coefficient and Bland-Altman plot analysis), and diagnostic performance (based on ROC AUC value, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy) of the cFFRML in terms of detection of significant stenosis were calculated. RESULTS. For tube voltages of 80, 100, and 120 kVp, the Spearman correlation coefficient for cFFRML in relation to the invasively measured FFR value was ρ = 0.684, ρ = 0.622, and ρ = 0.669, respectively (p < 0.001 for all). The corresponding intraclass correlation coefficient was 0.78, 0.76, and 0.77, respectively (p < 0.001 for all). Sensitivity was 100.0%, 73.5%, and 85.0%, and specificity was 76.2%, 79.0%, and 72.8% for tube voltages of 80, 100, and 120 kVp, respectively. The ROC AUC value was 0.90, 0.82, and 0.80 for 80, 100, and 120 kVp, respectively (p < 0.001 for all). CONCLUSION. CCTA-derived cFFRML is a robust method, and its performance does not vary significantly between examinations performed using tube voltages of 100 kVp and 120 kVp. However, because of rapid advancements in CT and postprocessing technology, further research is needed.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Aprendizaje Automático , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sistema de Registros , Estudios Retrospectivos , Sensibilidad y Especificidad
14.
Eur Radiol ; 28(5): 2134-2142, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29181587

RESUMEN

OBJECTIVES: To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. METHODS: One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). RESULTS: Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001). CONCLUSIONS: Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. KEY POINTS: • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/administración & dosificación , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Anciano , Femenino , Estudios de Seguimiento , Humanos , Inyecciones Intraarteriales , Masculino , Persona de Mediana Edad , Curva ROC , Dosis de Radiación
15.
Eur Radiol ; 28(8): 3405-3412, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29460070

RESUMEN

OBJECTIVES: To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). METHODS: Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-DECT (n = 100). SF-DECT scans were reconstructed and subdivided into composed images (SF-CI) and monoenergetic images at 55 keV (SF-MI). Objective and subjective image quality were compared among single-energy images (SEI), SF-CI and SF-MI. CNR and FOM were separately calculated for the liver (e.g. CNRliv) and the portal vein (CNRpv). Radiation dose was compared using size-specific dose estimate (SSDE). Results of the three groups were compared using non-parametric tests. RESULTS: Image noise of SF-CI was 18% lower compared to SEI and 48% lower compared to SF-MI (p < 0.001). Composed images yielded higher CNRliv over single-energy images (23.4 vs. 20.9; p < 0.001), whereas CNRpv was significantly lower (3.5 vs. 5.2; p < 0.001). Monoenergetic images overcame this inferiority in CNRpv and achieved similar results compared to single-energy images (5.1 vs. 5.2; p > 0.628). Subjective sharpness was equal between single-energy and monoenergetic images and diagnostic confidence was equal between single-energy and composed images. FOMliv was highest for SF-CI. FOMpv was equal for SEI and SF-MI (p = 0.78). SSDE was significant lower for SF-DECT compared to SECT (p < 0.022). CONCLUSIONS: The combined use of split-filter dual-energy CT images provides comparable objective and subjective image quality at lower radiation dose compared to single-energy CT with ATVS. KEY POINTS: • Split-filter dual-energy results in 18% lower noise compared to single-energy with ATVS. • Split-filter dual-energy results in 11% lower SSDE compared to single-energy with ATVS. • Spectral shaping of split-filter dual-energy leads to an increased dose-efficiency.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
16.
Can Assoc Radiol J ; 69(4): 390-396, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30249409

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the radiation dose and image quality at low tube-voltage pediatric chest computed tomographic angiography (CTA) that applies the same contrast-to-noise ratio (CNR) index as the standard tube voltage technique. MATERIALS AND METHODS: Contrast-enhanced chest CTA scans of 100 infants were acquired on a 64-row multidetector computed tomography (MDCT) scanner. In the retrospective study, we evaluated 50 images acquired at 120 kVp; the image noise level was set at 25 Hounsfield units. In the prospective study, we used an 80-kVp protocol; the image noise level was 40 Hounsfield units because the iodine contrast was 1.6 times higher than on 120-kVp scans; the CNR was as in the 120-kVp protocol. We compared the CT number, image noise, CT dose index volume (CTDIvol), and the dose-length product on scans acquired with the 2 protocols. A diagnostic radiologist and a pediatric cardiologist visually evaluated all CTA images. RESULTS: The mean CTDIvol and the mean dose-length product were 0.5 mGy and 7.8 mGy-cm for 80- and 1.2 mGy and 20.8 mGy-cm for 120-kVp scans, respectively (P < .001). The mean CTDIvol was 42% lower at 80 kVp than at 120 kVp, and there was no significant difference in the visual scores assigned to the CTA images (P = .28). CONCLUSIONS: With the CNR index being the same at 80-kVp and 120-kVp imaging, the radiation dose delivered to infants subjected to chest CTA can be reduced without degradation of the image quality.


Asunto(s)
Angiografía por Tomografía Computarizada/instrumentación , Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada Multidetector/instrumentación , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Radiografía Torácica/métodos , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos
17.
J Xray Sci Technol ; 26(3): 463-471, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29562576

RESUMEN

BACKGROUND: 640-slice coronary CT angiography is becoming an accurate and reliable method of diagnosing coronary heart disease. However, how to reduce the radiation dosage while ensuring the clinically acceptable image quality remains a quite challenging issue. OBJECTIVE: To evaluate the effect of low tube voltage on radiation dosage under 640-slice coronary CT angiography (CCTA). METHODS: Four hundred patients (236 males, 164 females) with coronary heart disease and underwent CCTA using DCVT were classified into A1 (tube voltage: 120 kV; exposure phase window: 30-80%), B1 (120 kV; 70-80%), A2 (100 kV; 30-80%) and B2 group (100 kV; 70-80%), respectively. Image qualities and effective dose (ED) were assessed and compared. RESULTS: No significant differences were observed among the groups in terms of age, height, weight and body mass index (BMI) (P > 0.05). ED were significantly lower in 100 kV group (P < 0.05). CT values of coronary artery in 100 kV groups were 13.5% and 17.3% higher than 120 kV group. ED in B1 group were 64.5% and 67.0% lower than A1 group. ED in B2 group were 65.4% and 65.2% lower than A2 group. CONCLUSION: When using a 640-slice CCTA prospective ECG-gating scanning mode, it is preferable to use a 100 kV tube voltage setting because compared to 120 kV tube voltage protocol, it seems to significantly decrease the mean effective radiation dose, without significantly lowering both the subjective and objective image quality.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Dosis de Radiación , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Relación Señal-Ruido
18.
Artículo en Japonés | MEDLINE | ID: mdl-29353837

RESUMEN

The purpose of this study was to investigate the effect of tube voltage on relationship between a patient's body weight and contrast enhancement in abdominal contrast-enhanced computed tomography (CT). Five phantoms with diameters ranging from 19.2 to 30.6 cm, including syringes filled with iodine solution diluted to different concentrations, were used to compare the effects at tube voltages of 80, 100, and 120 kVp. Furthermore, for clinical study, 300 patients who underwent abdominal contrast-enhanced CT examinations were enrolled and enhancements of aorta and hepatic parenchyma in arterial phase and equilibrium phase were compared at 80, 100, and 120 kVp using a contrast medium administration proportional to the body weight. The contrast enhancement was decreased with increase in phantom size because of the beam-hardening effect, and however, the decrease was less at low tube voltages of 80 and 100 kVp (lowest at 80 kVp), demonstrating the beam-hardening effect was reduced at low tube voltages. The enhancements of aorta and hepatic parenchyma indicated tended to increase in patients with a heavy body weight, and this trend was stronger at 80 and 100 kVp (80 kVp>100 kVp). Therefore, it was indicated that the problem of excessive contrast enhancement in patients with a high body weight was prominent at low tube voltages because the beam-hardening effect in patients with a heavy body weight was weaken by low tube voltages.


Asunto(s)
Abdomen/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador
19.
Eur Radiol ; 27(6): 2298-2308, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27682312

RESUMEN

PURPOSE: To investigate diagnostic accuracy of 3rd-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. METHODS: We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m2, n = 37) and B (≥30 kg/m2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. RESULTS: Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CONCLUSION: CCTA using 3rd-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. KEY POINTS: • Coronary CTA provides high diagnostic accuracy in non-obese and obese patients. • Diagnostic accuracy between obese and non-obese patients showed no significant difference. • <120 kV studies were performed in 44 % of obese patients. • Current radiation dose-saving approaches can be applied independent of body habitus.


Asunto(s)
Angiografía por Tomografía Computarizada/normas , Angiografía Coronaria/normas , Obesidad/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
20.
AJR Am J Roentgenol ; 208(1): 165-170, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27762605

RESUMEN

OBJECTIVE: The purpose of this study is to investigate the variation in attenuation values (expressed as Hounsfield units) for L1 vertebral body trabecular bone at different tube voltages used in dual-energy CT (DECT) and to remind physicians to consider changes in attenuation values when they approach opportunistic screening for osteoporosis. MATERIALS AND METHODS: Consecutive patients who underwent DECT examination of the abdomen and pelvis for suspected urolithiasis were included in the study. Attenuation noted on CT of the L1 trabecular bone performed with the use of tube voltages of 80, 100, and 140 kV was recorded. The correlation between the attenuation noted when the tube voltage was 140 kV and the attenuation noted when the tube voltage was either 80 or 100 kV was calculated, and differences in the mean CT attenuation values were compared. RESULTS: The mean attenuation values from L1 trabecular bone measurement performed for 191 patients were analyzed. As expected, the mean attenuation values decreased as the tube voltage increased. There was a strong correlation between the attenuation values noted when tube voltages of 80 and 140 kV were used (r2 = 0.97) and those noted when 100 and 140 kV were used (r2 = 0.96). The mean attenuation value noted at 80 kV was 76.4 HU (65%) higher than that noted at 140 kV (p < 0.001). The mean attenuation value at 100 kV was 45.5 HU (39.9%) higher than that noted at 140 kV (p < 0.001). CONCLUSION: We confirmed that attenuation values of L1 trabecular bone, unlike attenuation values of fat, fluid, or soft tissue, vary at different CT x-ray tube voltages. Therefore, standard reference attenuation values for trabecular bone seen at 120 kV cannot be applied to other single-energy settings, DECT, or CT examinations where dose modulation software automatically raises or lowers the tube voltage from 120 kV. Knowledge of the specific energy spectra used is essential before performing opportunistic CT evaluation for osteoporosis.


Asunto(s)
Huesos/diagnóstico por imagen , Errores Diagnósticos/prevención & control , Tamizaje Masivo/métodos , Osteoporosis/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA