Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(17)2023 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-37687899

RESUMEN

Formaldehyde is a known human carcinogen and an important indoor and outdoor air pollutant. However, current strategies for formaldehyde measurement, such as chromatographic and optical techniques, are expensive and labor intensive. Low-cost gas sensors have been emerging to provide effective measurement of air pollutants. In this study, we evaluated eight low-cost electrochemical formaldehyde sensors (SFA30, Sensirion®, Staefa, Switzerland) in the laboratory with a broadband cavity-enhanced absorption spectroscopy as the reference instrument. As a group, the sensors exhibited good linearity of response (R2 > 0.95), low limit of detection (11.3 ± 2.07 ppb), good accuracy (3.96 ± 0.33 ppb and 6.2 ± 0.3% N), acceptable repeatability (3.46% averaged coefficient of variation), reasonably fast response (131-439 s) and moderate inter-sensor variability (0.551 intraclass correlation coefficient) over the formaldehyde concentration range of 0-76 ppb. We also systematically investigated the effects of temperature and relative humidity on sensor response, and the results showed that formaldehyde concentration was the most important contributor to sensor response, followed by temperature, and relative humidity. The results suggest the feasibility of using this low-cost electrochemical sensor to measure formaldehyde concentrations at relevant concentration ranges in indoor and outdoor environments.

2.
Sensors (Basel) ; 18(11)2018 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-30373252

RESUMEN

Incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) is of importance for gas detection in environmental monitoring. This review summarizes the unique properties, development and recent progress of the IBBCEAS technique. Principle of IBBCEAS for gas sensing is described, and the development of IBBCEAS from the perspective of system structure is elaborated, including light source, cavity and detection scheme. Performances of the reported IBBCEAS sensor system in laboratory and field measurements are reported. Potential applications of this technique are discussed.

3.
Sci Total Environ ; 806(Pt 4): 150927, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34655639

RESUMEN

Vehicle exhaust gases are important sources of nitrous acid (HONO). In this study, HONO in diesel vehicle exhaust was measured by incoherent broadband cavity-enhanced absorption spectroscopy using a chassis dynamometer system. The mean HONO concentrations in exhaust gases emitted by passenger cars and light-duty trucks were high when the after treatment devices were not fully working during the warming up period. The HONO/NOx ratio is a good index of HONO formation. The HONO/NOx ratios were 9.7 × 10-3-18.1 × 10-3, and were higher than what we found in a previous study. The estimated HONO emission factors were 7.71-64.70 mg (kg fuel)-1, and were lower than were found in previous studies. The results indicated that the frequency particulate matter is removed from a diesel particle filter affects the HONO concentration in the emitted gases and the HONO emission factor.


Asunto(s)
Contaminantes Atmosféricos , Ácido Nitroso , Contaminantes Atmosféricos/análisis , Vehículos a Motor , Ácido Nitroso/análisis , Material Particulado/análisis , Emisiones de Vehículos/análisis
4.
Artículo en Inglés | MEDLINE | ID: mdl-30286400

RESUMEN

We describe the observation of the NO3 radical using an incoherent broadband cavity-enhanced absorption spectrometer in an open-path configuration (OP-IBBCEAS) in a polluted summer environment in continental China. The instrument was installed 17 m above the ground at the top of a residential complex near the CAREBeijing-NCP 2014 site in Wangdu, Hebei province, about 200 km southwest of Beijing over the period 28 to 30 June 2014. The separation between the transmitter and receiver components of the instrument was 335 cm and the effective pathlength in clean reference air was ~3.4 km. NO3 was detected above the detection limit on all three nights when the instrument was operational. The maximum mixing ratio measured was ~175 pptv with a detection sensitivity of ~36 pptv for measurements with an average acquisition time of 10 min. While most extractive instruments try to avoid interferences arising from aerosol extinction, the open path configuration has advantages owing to its ability to detect trace gases even in the presence of aerosol loading. Moreover, concurrent retrieval of aerosol optical extinction is possible from analysis of the absorption magnitude of the oxygen B-band at 687 nm. The experimental setup, its calibration, data acquisition, and analysis procedure are discussed, and the results presented here demonstrate the sensitivity and specificity that can be achieved at high spatial and temporal resolution using the novel configuration of IBBCEAS in the open path.

5.
ACS Sens ; 4(7): 1899-1908, 2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-31184106

RESUMEN

A near-infrared broadband cavity-enhanced sensor system was demonstrated for the first time using an energy-efficient light emitting diode (LED) with a central emission wavelength at 1650 nm and a light power of ∼16 mW. A portable absorption gas cell was designed for realizing a compact and stable optical system for easy alignment. An ultrashort 8-cm-long cavity was fabricated consisting of two mirrors with a ∼99.35% reflectivity. Methane (CH4) measurement was performed employing two detection schemes, i.e., NIRQuest InGaAs spectrometer and scanning monochromator combined with phase-sensitive detection. Retrieval of CH4 concentration was performed using a least-squares fitting algorithm. Sensitivities (i.e., minimum detectable absorption coefficient) were achieved of 1.25 × 10-6 cm-1 for an averaging time of 45 s using the NIRQuest InGaAs spectrometer and 1.85 × 10-6 cm-1 for an averaging time of 8 min using the scanning spectrometer in combination with lock-in detection. Field monitoring of CH4 gas leakage was performed using the NIRQuest spectrometer. Multigas sensing of CH4 and acetylene (C2H2) was carried out simultaneously using the high-resolution scanning spectrometer. A linear response of the retrieved concentration level versus nominal value was observed with a large dynamic range, demonstrating the reliability of the compact LED-based near-infrared broadband cavity-enhanced absorption spectroscopy (NIR-IBBCEAS) for multigas sensing applications.


Asunto(s)
Acetileno/análisis , Equipos y Suministros Eléctricos , Metano/análisis , Diseño de Equipo , Límite de Detección , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos
6.
Sci Total Environ ; 575: 287-293, 2017 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-27744156

RESUMEN

Nitrous acid (HONO) is a well-known source of hydroxyl radicals in the troposphere. Vehicle exhaust is considered to be one of the primary emission sources of HONO. In this study, measurements of HONO in gasoline vehicle exhaust were carried out using a chassis dynamometer combined with incoherent broadband cavity-enhanced absorption spectroscopy. When catalysts were warm, concentrations of HONO were higher than those prior to catalysts warming. Other species, such as CO, and total hydrocarbons (THCs), showed the opposite pattern. There were no correlations evident between HONO and other trace species concentrations immediately after emission. The HONO/NOx ratio, a good proxy for the formation of HONO in atmosphere, ranged from 1.1 to 6.8×10-3, which was consistent with previous studies. HONO emission factors (EFs) were calculated to be 0.01-3.6mgkg-1 fuel, which was different from the vehicle's specifications and those reported under different driving cycles. Annual HONO emissions in Japan were estimated using the calculated EFs and other statistical data.

7.
Mar Environ Res ; 92: 102-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24080409

RESUMEN

Kelps of the genus Laminaria accumulate iodine at high concentrations, but the iodine retaining capacity can be affected by emersion and physiological stress. In this study, I2 emission into the atmosphere from Laminaria digitata and Laminaria hyperborea was compared under controlled low irradiances and temperatures. The two species exhibited different I2 emission rates as blades of L. digitata emitted I2 at rates five times higher than those from newly-grown blades (current growth season) of L. hyperborea. I2 emission was not detectable from old blades (previous growth season) of L. hyperborea. Additionally, effects of irradiance and temperature on both I2 emission into air and net I(-) release into seawater where assessed for L. digitata while monitoring photo-physiological parameters as stress indicators. Irradiances between 30 and 120 µmol photons m(-2) s(-1) had only marginal effects on both I2 emission and I(-) release rates, but physiological stress, indicated by photoinhibition, was observed. The results suggest that the irradiances applied here were not stressful enough to impact on the iodine release. By contrast, at elevated temperatures (20 °C), photoinhibition was accompanied by an increase in I2 emission rates, but net I(-) release rates remained similar at 10-20 °C. High I2 emission rates into air and I(-) release into seawater observed from L. digitata underpin the fundamental function of this kelp as mediator of coastal iodine fluxes.


Asunto(s)
Yodo/metabolismo , Laminaria/fisiología , Meristema/metabolismo , Fotosíntesis , Agua de Mar , Estrés Fisiológico , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA