Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Am Acad Dermatol ; 2024 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-39251027

RESUMEN

BACKGROUND: Selective photothermolysis has limitations in efficacy and safety for dermal targets. We describe a novel concept using scanned focused laser microbeams for precise control of dermal depth and pattern of injury, using a 1550 nm laser that generates an array of conical thermal zones while minimizing injury to the epidermis. OBJECTIVE: To characterize the conical thermal zones in vivo and determine safe starting parameters to transition to a second phase to explore potential clinical indications. METHODS: A focused toroidal (ring) laser beam was delivered through a cold sapphire window, sparing epidermal injury in a central zone. Pulse energy, lesion depth, density, and energy delivery were titrated in ex vivo human skin and subsequently on the backs of 21 human subjects. RESULTS: Histology showed microscale patterns of thermal injury, which varied predictably with laser parameters. Time-course healing through histology and skin surface imaging demonstrated the ability of the device to deliver high energies without sequelae. LIMITATIONS: Clinical data are currently being collected to further explore the safety and efficacy of the device. CONCLUSION: The 1550 nm laser with focal point technology enables precise control of lesion depth while simultaneously sparing a large portion of the epidermis, lowering the risk of adverse effects.

2.
J Synchrotron Radiat ; 30(Pt 6): 1076-1085, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37815374

RESUMEN

Microbeam radiation therapy (MRT) is a radiotherapy technique combining spatial fractionation of the dose distribution on a micrometric scale, X-rays in the 50-500 keV range and dose rates up to 16 × 103 Gy s-1. Nowadays, in vivo dosimetry remains a challenge due to the ultra-high radiation fluxes involved and the need for high-spatial-resolution detectors. The aim here was to develop a striped diamond portal detector enabling online microbeam monitoring during synchrotron MRT treatments. The detector, a 550 µm bulk monocrystalline diamond, is an eight-strip device, of height 3 mm, width 178 µm and with 60 µm spaced strips, surrounded by a guard ring. An eight-channel ASIC circuit for charge integration and digitization has been designed and tested. Characterization tests were performed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility (ESRF). The detector measured direct and attenuated microbeams as well as interbeam fluxes with a precision level of 1%. Tests on phantoms (RW3 and anthropomorphic head phantoms) were performed and compared with simulations. Synchrotron radiation measurements were performed on an RW3 phantom for strips facing a microbeam and for strips facing an interbeam area. A 2% difference between experiments and simulations was found. In more complex geometries, a preliminary study showed that the absolute differences between simulated and recorded transmitted beams were within 2%. Obtained results showed the feasibility of performing MRT portal monitoring using a microstriped diamond detector. Online dosimetric measurements are currently ongoing during clinical veterinary trials at ESRF, and the next 153-strip detector prototype, covering the entire irradiation field, is being finalized at our institution.


Asunto(s)
Radiometría , Sincrotrones , Radiometría/métodos , Fraccionamiento de la Dosis de Radiación , Rayos X , Fantasmas de Imagen , Radioterapia , Método de Montecarlo , Diamante
3.
J Synchrotron Radiat ; 30(Pt 3): 591-595, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37067258

RESUMEN

Synchrotron microbeam radiation therapy (MRT) is based on the spatial fractionation of the incident synchrotron beam into arrays of parallel microbeams, typically a few tens of micrometres wide and depositing several hundred Gray. This high dose, high dose rate, spatially fractionated radiotherapy has a high therapeutic impact on tumors, especially in intracranial locations. MRT leads to better control of incurable high-grade glioma than from homogeneous radiotherapy. The schedule of MRT within a conventional irradiation protocol (three fractions of 11 Gy) of brain tumors was evaluated on the 9L glioma model in rats. MRT delivered as a first fraction increased the median survival time of the animals by four days compared with conventional radiotherapy, while the last MRT fraction improved the lifespan by 148% (+15.5 days compared with conventional radiotherapy, p < 0.0001). The most efficient radiation regimen was obtained when the MRT-boost was applied as the last fraction, following two conventional clinical exposures.


Asunto(s)
Neoplasias Encefálicas , Glioma , Ratas , Animales , Glioma/radioterapia , Neoplasias Encefálicas/radioterapia , Fraccionamiento de la Dosis de Radiación , Sincrotrones , Carmustina , Radioterapia/métodos
4.
J Synchrotron Radiat ; 30(Pt 2): 359-367, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36891849

RESUMEN

It has been shown lately that gold nanoparticles (AuNPs) and ionizing radiation (IR) have inhibitory effects on cancer cell migration while having promoting effects on normal cells' motility. Also, IR increases cancer cell adhesion with no significant effects on normal cells. In this study, synchrotron-based microbeam radiation therapy, as a novel pre-clinical radiotherapy protocol, is employed to investigate the effects of AuNPs on cell migration. Experiments were conducted utilizing synchrotron X-rays to investigate cancer and normal cell morphology and migration behaviour when they are exposed to synchrotron broad beams (SBB) and synchrotron microbeams (SMB). This in vitro study was conducted in two phases. In phase I two cancer cell lines - human prostate (DU145) and human lung (A549) - were exposed to various doses of SBB and SMB. Based on the phase I results, in phase II two normal cell lines were studied: human epidermal melanocytes (HEM) and human primary colon epithelial (CCD841), along with their respective cancerous counterparts, human primary melanoma (MM418-C1) and human colorectal adenocarcinoma (SW48). The results show that radiation-induced damage in cells' morphology becomes visible with SBB at doses greater than 50 Gy, and incorporating AuNPs increases this effect. Interestly, under the same conditions, no visible morphological changes were observed in the normal cell lines post-irradiation (HEM and CCD841). This can be attributed to the differences in cell metabolic and reactive oxygen species levels between normal and cancer cells. The outcome of this study highlights future applications of synchrotron-based radiotherapy, where it is possible to deliver extremely high doses to cancer tissues whilst preserving surrounding normal tissues from radiation-induced damage.


Asunto(s)
Nanopartículas del Metal , Neoplasias , Masculino , Humanos , Rayos X , Oro/farmacología , Sincrotrones , Radiografía
5.
Sensors (Basel) ; 23(4)2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36850532

RESUMEN

The fluid-structure interaction is one of the most important coupled problems in mechanics. The topic is crucial for many high-technology areas. This work considers the interaction between an elastic obstacle and rarefied gas flow, seeking specific problems that arise during this interaction. The Direct Simulation Monte Carlo method was used to model the rarefied gas flow and the linear Euler-Bernoulli beam theory was used to describe the motion of the elastic obstacle. It turned out that the vibrations caused by the gas flow could provoke a resonance-like phenomenon when the frequency of vortex shedding of the flow was close to the natural frequency of the beam. This phenomenon could be useful in certain high-technology applications.

6.
J Synchrotron Radiat ; 29(Pt 4): 1027-1032, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35787570

RESUMEN

Microbeam radiotherapy could help to cure malignant tumours which are currently still considered therapy-resistant. With an irradiation target in the thoracic cavity, the heart would be one of the most important organs at risk. To assess the acute adverse effects of microbeam irradiation in the heart, a powerful ex vivo tool was created by combining the Langendorff model of the isolated beating mammalian heart with X-Tream dosimetry. In a first pilot experiment conducted at the Biomedical and Imaging Beamline of the Australian Synchrotron, the system was tested at a microbeam peak dose approximately ten times higher than the anticipated future microbeam irradiation treatment doses. The entire heart was irradiated with a dose of 4000 Gy at a dose rate of >6000 Gy s-1, using an array of 50 µm-wide microbeams spaced at a centre-to-centre distance of 400 µm. Although temporary arrhythmias were seen, they reverted spontaneously to a stable rhythm and no cardiac arrest occurred. This amazing preservation of cardiac function is promising for future therapeutic approaches.


Asunto(s)
Radiometría , Sincrotrones , Animales , Australia , Mamíferos , Radiometría/métodos
7.
J Synchrotron Radiat ; 29(Pt 6): 1480-1494, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36345756

RESUMEN

The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 1012 photons s-1), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5-18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.


Asunto(s)
Sincrotrones , Cristalografía por Rayos X , Sustancias Macromoleculares/química
8.
J Synchrotron Radiat ; 29(Pt 1): 125-137, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985430

RESUMEN

Successful transition of synchrotron-based microbeam radiation therapy (MRT) from pre-clinical animal studies to human trials is dependent upon ensuring that there are sufficient and adequate measures in place for quality assurance purposes. Transmission detectors provide researchers and clinicians with a real-time quality assurance and beam-monitoring instrument to ensure safe and accurate dose delivery. In this work, the effect of transmission detectors of different thicknesses (10 and 375 µm) upon the photon energy spectra and dose deposition of spatially fractionated synchrotron radiation is quantified experimentally and by means of a dedicated Geant4 simulation study. The simulation and experimental results confirm that the presence of the 375 µm thick transmission detector results in an approximately 1-6% decrease in broad-beam and microbeam peak dose. The capability to account for the reduction in dose and change to the peak-to-valley dose ratio justifies the use of transmission detectors as thick as 375 µm in MRT provided that treatment planning systems are able to account for their presence. The simulation and experimental results confirm that the presence of the 10 µm thick transmission detector shows a negligible impact (<0.5%) on the photon energy spectra, dose delivery and microbeam structure for both broad-beam and microbeam cases. Whilst the use of 375 µm thick detectors would certainly be appropriate, based upon the idea of best practice the authors recommend that 10 µm thick transmission detectors of this sort be utilized as a real-time quality assurance and beam-monitoring tool during MRT.


Asunto(s)
Silicio , Sincrotrones , Animales , Australia , Humanos , Método de Montecarlo , Dosificación Radioterapéutica
9.
Int J Mol Sci ; 23(15)2022 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-35955454

RESUMEN

Microbeam radiotherapy (MRT), an experimental high-dose rate concept with spatial fractionation at the micrometre range, has shown a high therapeutic potential as well as good preservation of normal tissue function in pre-clinical studies. We investigated the suitability of MRT as a simultaneously integrated boost (SIB) in conventional whole-brain irradiation (WBRT). A 174 Gy MRT SIB was administered with an array of quasi-parallel, 50 µm wide microbeams spaced at a centre-to-centre distance of 400 µm either on the first or last day of a 5 × 4 Gy radiotherapy schedule in healthy adult C57 BL/6J mice and in F98 glioma cell cultures. The animals were observed for signs of intracranial pressure and focal neurologic signs. Colony counts were conducted in F98 glioma cell cultures. No signs of acute adverse effects were observed in any of the irradiated animals within 3 days after the last irradiation fraction. The tumoricidal effect on F98 cell in vitro was higher when the MRT boost was delivered on the first day of the irradiation course, as opposed to the last day. Therefore, the MRT SIB should be integrated into a clinical radiotherapy schedule as early as possible.


Asunto(s)
Neoplasias Encefálicas , Glioma , Animales , Encéfalo/efectos de la radiación , Neoplasias Encefálicas/radioterapia , Fraccionamiento de la Dosis de Radiación , Glioma/radioterapia , Ratones , Dosis de Radiación , Sincrotrones
10.
Int J Mol Sci ; 23(17)2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36077349

RESUMEN

Radiotherapy is an important component in the treatment of lung cancer, one of the most common cancers worldwide, frequently resulting in death within only a few years of diagnosis. In order to evaluate new therapeutic approaches and compare their efficiency with regard to tumour control at a pre-clinical stage, it is important to develop standardized samples which can serve as inter-institutional outcome controls, independent of differences in local technical parameters or specific techniques. Recent developments in 3D bioprinting techniques could provide a sophisticated solution to this challenge. We have conducted a pilot project to evaluate the suitability of standardized samples generated from 3D printed human lung cancer cells in radiotherapy studies. The samples were irradiated at high dose rates using both broad beam and microbeam techniques. We found the 3D printed constructs to be sufficiently mechanically stable for use in microbeam studies with peak doses up to 400 Gy to test for cytotoxicity, DNA damage, and cancer cell death in vitro. The results of this study show how 3D structures generated from human lung cancer cells in an additive printing process can be used to study the effects of radiotherapy in a standardized manner.


Asunto(s)
Bioimpresión , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/radioterapia , Proyectos Piloto , Impresión Tridimensional
11.
J Cell Sci ; 132(19)2019 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-31492757

RESUMEN

Nucleoli have attracted interest for their role as cellular stress sensors and as potential targets for cancer treatment. The effect of DNA double-strand breaks (DSBs) in nucleoli on rRNA transcription and nucleolar organisation appears to depend on the agent used to introduce DSBs, DSB frequency and the presence (or not) of DSBs outside the nucleoli. To address the controversy, we targeted nucleoli with carbon ions at the ion microbeam SNAKE. Localized ion irradiation with 1-100 carbon ions per point (about 0.3-30 Gy per nucleus) did not lead to overall reduced ribonucleotide incorporation in the targeted nucleolus or other nucleoli of the same cell. However, both 5-ethynyluridine incorporation and Parp1 protein levels were locally decreased at the damaged nucleolar chromatin regions marked by γH2AX, suggesting localized inhibition of rRNA transcription. This locally restricted transcriptional inhibition was not accompanied by nucleolar segregation, a structural reorganisation observed after inhibition of rRNA transcription by treatment with actinomycin D or UV irradiation. The presented data indicate that even multiple complex DSBs do not lead to a pan-nucleolar response if they affect only a subnucleolar region.


Asunto(s)
Nucléolo Celular/metabolismo , Proteínas del Complejo de Iniciación de Transcripción Pol1/genética , ARN Ribosómico/genética , Línea Celular Tumoral , Roturas del ADN de Doble Cadena , ADN Ribosómico/genética , Humanos , Región Organizadora del Nucléolo/genética , Región Organizadora del Nucléolo/metabolismo , Poli(ADP-Ribosa) Polimerasa-1/genética , Transcripción Genética/genética
12.
J Synchrotron Radiat ; 28(Pt 2): 410-418, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33650552

RESUMEN

It has been shown previously both in vitro and in vivo that microbeam irradiation (MBI) can control malignant tumour cells more effectively than the clinically established concepts of broad beam irradiation. With the aim to extend the international capacity for microbeam research, the first MBI experiment at the biomedical beamline SYRMEP of the Italian synchrotron facility ELETTRA has been conducted. Using a multislit collimator produced by the company TECOMET, arrays of quasi-parallel microbeams were successfully generated with a beam width of 50 µm and a centre-to-centre distance of 400 µm. Murine melanoma cell cultures were irradiated with a target dose of approximately 65 Gy at a mean photon energy of ∼30 keV with a dose rate of 70 Gy s-1 and a peak-to-valley dose of ∼123. This work demonstrated a melanoma cell reduction of approximately 80% after MBI. It is suggested that, while a high energy is essential to achieve high dose rates in order to deposit high treatment doses in a short time in a deep-seated target, for in vitro studies and for the treatment of superficial tumours a spectrum in the lower energy range might be equally suitable or even advantageous.


Asunto(s)
Fotones , Sincrotrones , Animales , Ratones , Método de Montecarlo
13.
J Synchrotron Radiat ; 28(Pt 6): 1954-1965, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34738951

RESUMEN

The optical design and performance of the recently opened 13A biological small-angle X-ray scattering (SAXS) beamline at the 3.0 GeV Taiwan Photon Source of the National Synchrotron Radiation Research Center are reported. The beamline is designed for studies of biological structures and kinetics in a wide range of length and time scales, from angstrom to micrometre and from microsecond to minutes. A 4 m IU24 undulator of the beamline provides high-flux X-rays in the energy range 4.0-23.0 keV. MoB4C double-multilayer and Si(111) double-crystal monochromators (DMM/DCM) are combined on the same rotating platform for a smooth rotation transition from a high-flux beam of ∼4 × 1014 photons s-1 to a high-energy-resolution beam of ΔE/E ≃ 1.5 × 10-4; both modes share a constant beam exit. With a set of Kirkpatrick-Baez (KB) mirrors, the X-ray beam is focused to the farthest SAXS detector position, 52 m from the source. A downstream four-bounce crystal collimator, comprising two sets of Si(311) double crystals arranged in a dispersive configuration, optionally collimate the DCM (vertically diffracted) beam in the horizontal direction for ultra-SAXS with a minimum scattering vector q down to 0.0004 Å-1, which allows resolving ordered d-spacing up to 1 µm. A microbeam, of 10-50 µm beam size, is tailored by a combined set of high-heat-load slits followed by micrometre-precision slits situated at the front-end 15.5 m position. The second set of KB mirrors then focus the beam to the 40 m sample position, with a demagnification ratio of ∼1.5. A detecting system comprising two in-vacuum X-ray pixel detectors is installed to perform synchronized small- and wide-angle X-ray scattering data collections. The observed beamline performance proves the feasibility of having compound features of high flux, microbeam and ultra-SAXS in one beamline.


Asunto(s)
Fotones , Sincrotrones , Dispersión del Ángulo Pequeño , Taiwán , Difracción de Rayos X , Rayos X
14.
J Synchrotron Radiat ; 28(Pt 5): 1444-1454, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34475292

RESUMEN

Spatially fractionated ultra-high-dose-rate beams used during microbeam radiation therapy (MRT) have been shown to increase the differential response between normal and tumour tissue. Quality assurance of MRT requires a dosimeter that possesses tissue equivalence, high radiation tolerance and spatial resolution. This is currently an unsolved challenge. This work explored the use of a 500 nm thick organic semiconductor for MRT dosimetry on the Imaging and Medical Beamline at the Australian Synchrotron. Three beam filters were used to irradiate the device with peak energies of 48, 76 and 88 keV with respective dose rates of 3668, 500 and 209 Gy s-1. The response of the device stabilized to 30% efficiency after an irradiation dose of 30 kGy, with a 0.5% variation at doses of 35 kGy and higher. The calibration factor after pre-irradiation was determined to be 1.02 ±â€…0.005 µGy per count across all three X-ray energy spectra, demonstrating the unique advantage of using tissue-equivalent materials for dosimetry. The percentage depth dose curve was within ±5% of the PTW microDiamond detector. The broad beam was fractionated into 50 microbeams (50 µm FHWM and 400 µm centre-to-centre distance). For each beam filter, the FWHMs of all 50 microbeams were measured to be 51 ±â€…1.4, 53 ±â€…1.4 and 69 ±â€…1.9 µm, for the highest to lowest dose rate, respectively. The variation in response suggested the photodetector possessed dose-rate dependence. However, its ability to reconstruct the microbeam profile was affected by the presence of additional dose peaks adjacent to the one generated by the X-ray microbeam. Geant4 simulations proved that the additional peaks were due to optical photons generated in the barrier film coupled to the sensitive volume. The simulations also confirmed that the amplitude of the additional peak in comparison with the microbeam decreased for spectra with lower peak energies, as observed in the experimental data. The material packaging can be optimized during fabrication by solution processing onto a flexible substrate with a non-fluorescent barrier film. With these improvements, organic photodetectors show promising prospects as a cost-effective high spatial resolution tissue-equivalent flexible dosimeter for synchrotron radiation fields.


Asunto(s)
Radioterapia/instrumentación , Semiconductores , Fraccionamiento de la Dosis de Radiación , Diseño de Equipo , Dosímetros de Radiación , Dosificación Radioterapéutica , Sincrotrones , Rayos X
15.
J Synchrotron Radiat ; 28(Pt 2): 392-403, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33650550

RESUMEN

Microbeam radiation therapy (MRT) is a developing radiotherapy, based on the use of beams only a few tens of micrometres wide, generated by synchrotron X-ray sources. The spatial fractionation of the homogeneous beam into an array of microbeams is possible using a multislit collimator (MSC), i.e. a machined metal block with regular apertures. Dosimetry in MRT is challenging and previous works still show differences between calculated and experimental dose profiles of 10-30%, which are not acceptable for a clinical implementation of treatment. The interaction of the X-rays with the MSC may contribute to the observed discrepancies; the present study therefore investigates the dose contribution due to radiation interaction with the MSC inner walls and radiation leakage of the MSC. Dose distributions inside a water-equivalent phantom were evaluated for different field sizes and three typical spectra used for MRT studies at the European Synchrotron Biomedical beamline ID17. Film dosimetry was utilized to determine the contribution of radiation interaction with the MSC inner walls; Monte Carlo simulations were implemented to calculate the radiation leakage contribution. Both factors turned out to be relevant for the dose deposition, especially for small fields. Photons interacting with the MSC walls may bring up to 16% more dose in the valley regions, between the microbeams. Depending on the chosen spectrum, the radiation leakage close to the phantom surface can contribute up to 50% of the valley dose for a 5 mm × 5 mm field. The current study underlines that a detailed characterization of the MSC must be performed systematically and accurate MRT dosimetry protocols must include the contribution of radiation leakage and radiation interaction with the MSC in order to avoid significant errors in the dose evaluation at the micrometric scale.


Asunto(s)
Radiometría , Sincrotrones , Método de Montecarlo , Fantasmas de Imagen , Dosificación Radioterapéutica , Rayos X
16.
Int J Mol Sci ; 22(18)2021 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-34575973

RESUMEN

Radiation damages many cellular components and disrupts cellular functions, and was previously reported to impair locomotion in the model organism Caenorhabditis elegans. However, the response to even higher doses is not clear. First, to investigate the effects of high-dose radiation on the locomotion of C. elegans, we investigated the dose range that reduces whole-body locomotion or leads to death. Irradiation was performed in the range of 0-6 kGy. In the crawling analysis, motility decreased after irradiation in a dose-dependent manner. Exposure to 6 kGy of radiation affected crawling on agar immediately and caused the complete loss of motility. Both γ-rays and carbon-ion beams significantly reduced crawling motility at 3 kGy. Next, swimming in buffer was measured as a motility index to assess the response over time after irradiation and motility similarly decreased. However, swimming partially recovered 6 h after irradiation with 3 kGy of γ-rays. To examine the possibility of a recovery mechanism, in situ GFP reporter assay of the autophagy-related gene lgg-1 was performed. The fluorescence intensity was stronger in the anterior half of the body 7 h after irradiation with 3 kGy of γ-rays. GFP::LGG-1 induction was observed in the pharynx, neurons along the body, and the intestine. Furthermore, worms were exposed to region-specific radiation with carbon-ion microbeams and the trajectory of crawling was measured by image processing. Motility was lower after anterior-half body irradiation than after posterior-half body irradiation. This further supported that the anterior half of the body is important in the locomotory response to radiation.


Asunto(s)
Autofagia/efectos de la radiación , Locomoción/efectos de la radiación , Dosis de Radiación , Animales , Autofagia/fisiología , Caenorhabditis elegans/fisiología , Caenorhabditis elegans/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Rayos gamma/efectos adversos , Humanos , Locomoción/fisiología , Irradiación Corporal Total/efectos adversos
17.
Int J Mol Sci ; 22(14)2021 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-34299373

RESUMEN

Melanoma is the deadliest type of skin cancer, due to its invasiveness and limited treatment efficacy. The main therapy for primary melanoma and solitary organ metastases is wide excision. Adjuvant therapy, such as chemotherapy and targeted therapies are mainly used for disseminated disease. Radiotherapy (RT) is a powerful treatment option used in more than 50% of cancer patients, however, conventional RT alone is unable to eradicate melanoma. Its general radioresistance is attributed to overexpression of repair genes in combination with cascades of biochemical repair mechanisms. A novel sophisticated technique based on synchrotron-generated, spatially fractionated RT, called Microbeam Radiation Therapy (MRT), has been shown to overcome these treatment limitations by allowing increased dose delivery. With MRT, a collimator subdivides the homogeneous radiation field into an array of co-planar, high-dose microbeams that are tens of micrometres wide and spaced a few hundred micrometres apart. Different preclinical models demonstrated that MRT has the potential to completely ablate tumours, or significantly improve tumour control while dramatically reducing normal tissue toxicity. Here, we discuss the role of conventional RT-induced immunity and the potential for MRT to enhance local and systemic anti-tumour immune responses. Comparative gene expression analysis from preclinical tumour models indicated a specific gene signature for an 'MRT-induced immune effect'. This focused review highlights the potential of MRT to overcome the inherent radioresistance of melanoma which could be further enhanced for future clinical use with combined treatment strategies, in particular, immunotherapy.


Asunto(s)
Melanoma/radioterapia , Animales , Terapia Combinada/métodos , Humanos , Inmunidad/inmunología , Inmunoterapia/métodos , Melanoma/inmunología , Melanoma/terapia , Radioterapia/métodos , Sincrotrones
18.
Int J Mol Sci ; 22(23)2021 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-34884589

RESUMEN

The non-targeted effects of radiation have been known to induce significant alternations in cell survival. Although the effects might govern the progression of tumor sites following advanced radiotherapy, the impacts on the intercellular control of the cell cycle following radiation exposure with a modified field, remain to be determined. Recently, a fluorescent ubiquitination-based cell-cycle indicator (FUCCI), which can visualize the cell-cycle phases with fluorescence microscopy in real time, was developed for biological cell research. In this study, we investigated the non-targeted effects on the regulation of the cell cycle of human cervical carcinoma (HeLa) cells with imperfect p53 function that express the FUCCI (HeLa-FUCCI cells). The possible effects on the cell-cycle phases via soluble factors were analyzed following exposure to different field configurations, which were delivered using a 150 kVp X-ray irradiator. In addition, using synchrotron-generated, 5.35 keV monochromatic X-ray microbeams, high-precision 200 µm-slit microbeam irradiation was performed to investigate the possible impacts on the cell-cycle phases via cell-cell contacts. Collectively, we could not detect the intercellular regulation of the cell cycle in HeLa-FUCCI cells, which suggested that the unregulated cell growth was a malignant tumor. Our findings indicated that there was no significant intercellular control system of the cell cycle in malignant tumors during or after radiotherapy, highlighting the differences between normal tissue and tumor characteristics.


Asunto(s)
Ciclo Celular , Colorantes Fluorescentes/química , Sincrotrones/instrumentación , Ubiquitinación , Neoplasias del Cuello Uterino/patología , Supervivencia Celular , Femenino , Células HeLa , Humanos , Microscopía Fluorescente , Rayos X
19.
Int J Mol Sci ; 22(14)2021 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-34299263

RESUMEN

BACKGROUND: Charged-particle radiotherapy is an emerging treatment modality for radioresistant tumors. The enhanced effectiveness of high-energy particles (such as heavy ions) has been related to the spatial clustering of DNA lesions due to highly localized energy deposition. Here, DNA damage patterns induced by single and multiple carbon ions were analyzed in the nuclear chromatin environment by different high-resolution microscopy approaches. MATERIAL AND METHODS: Using the heavy-ion microbeam SNAKE, fibroblast monolayers were irradiated with defined numbers of carbon ions (1/10/100 ions per pulse, ipp) focused to micrometer-sized stripes or spots. Radiation-induced lesions were visualized as DNA damage foci (γH2AX, 53BP1) by conventional fluorescence and stimulated emission depletion (STED) microscopy. At micro- and nanoscale level, DNA double-strand breaks (DSBs) were visualized within their chromatin context by labeling the Ku heterodimer. Single and clustered pKu70-labeled DSBs were quantified in euchromatic and heterochromatic regions at 0.1 h, 5 h and 24 h post-IR by transmission electron microscopy (TEM). RESULTS: Increasing numbers of carbon ions per beam spot enhanced spatial clustering of DNA lesions and increased damage complexity with two or more DSBs in close proximity. This effect was detectable in euchromatin, but was much more pronounced in heterochromatin. Analyzing the dynamics of damage processing, our findings indicate that euchromatic DSBs were processed efficiently and repaired in a timely manner. In heterochromatin, by contrast, the number of clustered DSBs continuously increased further over the first hours following IR exposure, indicating the challenging task for the cell to process highly clustered DSBs appropriately. CONCLUSION: Increasing numbers of carbon ions applied to sub-nuclear chromatin regions enhanced the spatial clustering of DSBs and increased damage complexity, this being more pronounced in heterochromatic regions. Inefficient processing of clustered DSBs may explain the enhanced therapeutic efficacy of particle-based radiotherapy in cancer treatment.


Asunto(s)
Roturas del ADN de Doble Cadena/efectos de la radiación , ADN/efectos de la radiación , Radioterapia de Iones Pesados/efectos adversos , Técnicas de Cultivo de Célula , Análisis por Conglomerados , Daño del ADN/efectos de la radiación , Reparación del ADN/efectos de la radiación , Eucromatina/genética , Eucromatina/efectos de la radiación , Fibroblastos , Radioterapia de Iones Pesados/métodos , Iones Pesados/efectos adversos , Heterocromatina/genética , Heterocromatina/efectos de la radiación , Humanos , Autoantígeno Ku/genética , Autoantígeno Ku/efectos de la radiación , Transferencia Lineal de Energía/efectos de la radiación , Microscopía Electrónica/métodos , Radiación Ionizante
20.
J Synchrotron Radiat ; 27(Pt 6): 1590-1600, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33147183

RESUMEN

The physical absorbed dose enhancement by the inclusion of gold and bismuth nanoparticles fabricated into water-equivalent PRESAGE dosimeters was investigated. Nanoparticle-loaded water-equivalent PRESAGE dosimeters were irradiated with superficial, synchrotron and megavoltage X-ray beams. The change in optical density of the dosimeters was measured using UV-Vis spectrophotometry pre- and post-irradiation using a wavelength of 630 nm. Dose enhancement was measured for 5 nm and 50 nm monodispersed gold nanoparticles, 5-50 nm polydispersed bismuth nanoparticles, and 80 nm monodispersed bismuth nanoparticles at concentrations from 0.25 mM to 2 mM. The dose enhancement was highest for the 95.3 keV mean energy synchrotron beam (16-32%) followed by the 150 kVp superficial beam (12-21%) then the 6 MV beam (2-5%). The bismuth nanoparticle-loaded dosimeters produced a larger dose enhancement than the gold nanoparticle-loaded dosimeters in the synchrotron beam for the same concentration. For the superficial and megavoltage beams the dose enhancement was similar for both species of nanoparticles. The dose enhancement increased with nanoparticle concentration in the dosimeters; however, there was no observed nanoparticle size dependence on the dose enhancement.


Asunto(s)
Nanopartículas del Metal/química , Dosímetros de Radiación , Radioterapia/métodos , Bismuto/química , Diseño de Equipo , Oro/química , Dosis de Radiación , Análisis Espectral , Sincrotrones , Agua , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA