Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 500
Filtrar
Más filtros

Intervalo de año de publicación
1.
Gerontology ; : 1-11, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38838650

RESUMEN

BACKGROUND: Footwear, orthoses, and insoles have been shown to influence balance in older adults; however, it remains unclear which features, singular or in combination, are considered optimal. The aim of this scoping review was to identify and synthesise the current evidence regarding how footwear, orthoses, and insoles influence balance in older adults. Four electronic databases (MEDLINE, CINAHL, Embase, and AMED) were searched from inception to October 2023. Key terms such as "shoe*," "orthoses," "postural balance" and "older people" were employed in the search strategy. Studies meeting the following criteria were included: (i) participants had a minimum age ≥60 years, and were free of any neurological, musculoskeletal, and cardiovascular diseases; (ii) an active intervention consisting of footwear, foot orthoses, or insoles was evaluated; and (iii) at least one objective outcome measure of balance was reported. SUMMARY: A total of 56 studies from 17 different countries were included. Three study designs were utilised (cross-sectional study, n = 44; randomised parallel group, n = 6; cohort study n = 6). The duration of studies varied considerably, with 41 studies evaluating immediate effects, 14 evaluating effects from 3 days to 12 weeks, and 1 study having a duration of 6 months. Seventeen different interventions were evaluated, including/consisting of textured insoles (n = 12), heel elevation (n = 8), non-specific standardised footwear and changes in sole thickness or hardness (n = 7 each), sole geometry or rocker soles, contoured or custom insoles and high collar height (n = 6 each), insole thickness or hardness and vibrating insoles (n = 5 each), outsole tread (n = 4), minimalist footwear and slippers (n = 3 each), balance-enhancing shoes, footwear fit, socks, and ankle-foot orthoses (n = 2 each), and eversion insoles, heel cups, and unstable footwear (n = 1 each). Twenty-three different outcomes were assessed, and postural sway was the most common (n = 20), followed by temporo-spatial gait parameters (n = 17). There was uncertainty regarding intervention effectiveness. Overall, features such as secure fixation, a textured insole, a medium-to-hard density midsole and a higher ankle collar, in isolation, were able to positively impact balance. Conversely, footwear with an elevated heel height and the use of socks and slippers impaired balance. KEY MESSAGES: There is a substantial body of literature exploring the effects of footwear, orthoses, and insoles on balance in older adults. However, considerable uncertainty exists regarding the efficacy of these interventions due to variability in methodological approaches. Further high-quality research is necessary to determine whether a singular intervention or a combination of interventions is most effective for enhancing balance in older adults.

2.
Gerontology ; : 1-13, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38776890

RESUMEN

INTRODUCTION: Nearly, a quarter of older adults suffer from frequent foot pain, impacting their quality of life. While proper footwear can alleviate this, design issues often hinder regular use. This study evaluated novel therapeutic footwear, designed for aesthetics and custom fit, to reduce foot pain. We hypothesized that older adults would experience less foot pain and favor the new footwear over their own. METHODS: This 12-week crossover randomized controlled trial evaluated the effectiveness of OrthoFeet therapeutic footwear on reducing foot pain in older adults (n = 50, age = 65 ± 5, 18% male) with moderate to severe pain. Participants were assigned to either the AB or BA sequence. In AB, they wore OrthoFeet shoes for 6 weeks and then their own shoes for another 6 weeks; BA followed the reverse order. Pain and function were measured using the Foot Function Index. Acceptability was assessed through a technology acceptance model (TAM) questionnaire. Data collected at baseline, six, and 12 weeks were analyzed using t tests, χ2 tests, and generalized linear model. RESULTS: Compared to participants' own shoes, OrthoFeet shoes significantly reduced foot pain and disability. Notable improvements were observed in "foot pain at its worst," "foot pain at the end of the day," "overall pain score," and "overall Foot Function Index score," all showing statistically significant reductions (p < 0.050). Participants reported high adherence to wearing the OrthoFeet shoes, averaging 8 h per day and 5.8 days per week. TAM scores favored OrthoFeet shoes over participants' own shoes in terms of ease of use, perceived benefit, and intention to recommend. Significant differences were noted in components representing perceived joint pain relief (p < 0.001, χ2 = 21.228) and the intention of use as determined by the likelihood of recommending the shoes to a friend with a similar condition (p < 0.001, χ2 = 29.465). Additionally, a majority of participants valued the appearance of the shoes, with 66% prioritizing shoe appearance and 96% finding the study shoes more stylish than their previous ones. CONCLUSION: This study underscores the significance of design and custom fit in promoting continuous wear for effective foot pain reduction in older adults. More research is needed on the intervention's long-term impacts.

3.
Arch Phys Med Rehabil ; 105(7): 1322-1329, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38458374

RESUMEN

OBJECTIVE: To investigate the immediate effects of plastic ankle-foot orthosis (AFO) on locomotor performance in patients with stroke and determine how such effects might undergo alteration when distinct plantarflexor (PF) module subtypes are considered. DESIGN: Cross-sectional study. SETTING: Two university hospitals. PARTICIPANTS: Fifty-two patients with stroke and 21 of those without stroke (N=73). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Motor modules were identified through non-negative matrix factorization, and participants were classified into 3 groups: independent-normal-timing, independent-altered-timing, and merged PF modules. To assess the effects of the AFO, gait measurements reflecting locomotor performance were obtained with and without the presence of the plastic AFO for each group. RESULTS: The independent-altered-timing group had increased paretic propulsion, greater non-paretic step length, and faster walking speed after the administration of the plastic AFO; however, these significant changes were not observed in the independent-normal-timing and merged PF module groups. Notably, patients in the independent-normal-timing and merged PF module groups exhibited longer paretic stance times. CONCLUSION: This study suggests that the immediate effects of plastic AFO depend on the PF module subtype. These findings can potentially guide clinical decision-making regarding AFO selection for stroke rehabilitation in patients with diverse gait control characteristics.


Asunto(s)
Ortesis del Pié , Trastornos Neurológicos de la Marcha , Rehabilitación de Accidente Cerebrovascular , Humanos , Estudios Transversales , Masculino , Femenino , Persona de Mediana Edad , Rehabilitación de Accidente Cerebrovascular/métodos , Anciano , Trastornos Neurológicos de la Marcha/rehabilitación , Trastornos Neurológicos de la Marcha/fisiopatología , Trastornos Neurológicos de la Marcha/etiología , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/fisiopatología , Marcha/fisiología , Velocidad al Caminar/fisiología , Diseño de Equipo
4.
BMC Musculoskelet Disord ; 25(1): 409, 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38783248

RESUMEN

BACKGROUND: The hallux dorsiflexion resistance test is a frequently employed clinical maneuver for assessing the initiation of the windlass mechanism This maneuver involves dorsiflexion of the phalanx of the hallux, thereby evaluating plantarflexion of the first metatarsal, elevation of the medial longitudinal arch, and supination of the rearfoot. The windlass mechanism plays a crucial role in gait, and orthopedic devices, such as a kinetic wedge, which aims to facilitate its activation by increasing the hallux dorsiflexion. Although it is believed that facilitating the windlass mechanism with the kinetic wedge should be directly correlated with a decrease in hallux dorsiflexion resistance, its effects have yet to be characterized. Thus, this study aimed to determine the influence of a kinetic wedge on hallux dorsiflexion resistance in asymptomatic individuals. METHODS: The sample comprised thirty participants (14 women and 16 men). A digital force gauge measured the force required to perform the hallux dorsiflexion resistance test during two conditions: barefoot and with a kinetic wedge. The Wilcoxon signed-rank test was used to compare the hallux dorsiflexion resistance between conditions. RESULTS: A statistically significant reduction in force (10.54 ± 3.16N vs. 19.62 ± 5.18N, p < 0.001) was observed when using the kinetic wedge compared to the barefoot condition during the hallux dorsiflexion resistance test. CONCLUSION: The use of a kinetic wedge reduces the required force for performing the passive hallux dorsiflexion resistance test in asymptomatic individuals. Future studies should determine to what extent the kinetic wedge can attenuate the required force to dorsiflex the hallux in individuals with musculoskeletal disorders such as plantar fasciopathy and functional hallux limitus.


Asunto(s)
Hallux , Humanos , Femenino , Masculino , Adulto , Hallux/fisiología , Adulto Joven , Fenómenos Biomecánicos/fisiología , Marcha/fisiología , Rango del Movimiento Articular/fisiología
5.
BMC Musculoskelet Disord ; 25(1): 425, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38822269

RESUMEN

BACKGROUND: The Ponseti method for treating clubfoot consists of initial treatment with serial casting accompanied by achillotenotomy if needed, followed by the maintenance phase including treatment with a foot abduction orthosis (FAO) for at least four years. This study aimed to examine the duration, course, and outcome of orthotic treatment in children with clubfoot. METHODS: 321 children with clubfoot, born between 2015 and 2017, registered in the Swedish Pediatric Orthopedic Quality Register (SPOQ), were included in this prospective cohort study. Data on deformity characteristics and orthotic treatment were extracted. For children with bilateral clubfoot, one foot was included in the analysis. RESULTS: Of the 288 children with isolated clubfoot, 274 children (95.5%) were prescribed an FAO, and 100 children (35%) changed orthosis type before 4 years of age. Of the 33 children with non-isolated clubfoot, 25 children (76%) were prescribed an FAO, and 21 children (64%) changed orthosis type before 4 years of age. 220 children with isolated clubfoot (76%), and 28 children with non-isolated clubfoot (84%) continued orthotic treatment until 4 years of age or longer. Among children with isolated clubfoot, children ending orthotic treatment before 4 years of age (n = 63) had lower Pirani scores at birth compared to children ending orthotic treatment at/after 4 years of age (n = 219) (p = 0.01). It was more common to change orthosis type among children ending orthotic treatment before 4 years of age (p = 0.031). CONCLUSIONS: The majority of children with clubfoot in Sweden are treated with an FAO during the maintenance phase. The proportion of children changing orthosis type was significantly greater and the Pirani score at diagnosis was lower significantly among children ending orthotic treatment before 4 years of age. Long-term follow-up studies are warranted to fully understand how to optimize, and individualize, orthotic treatment with respect to foot involvement and severity of deformity. LEVEL OF EVIDENCE: II.


Asunto(s)
Pie Equinovaro , Ortesis del Pié , Sistema de Registros , Humanos , Pie Equinovaro/terapia , Suecia/epidemiología , Masculino , Femenino , Preescolar , Estudios de Seguimiento , Resultado del Tratamiento , Estudios Prospectivos , Lactante , Niño , Factores de Tiempo , Moldes Quirúrgicos/tendencias , Aparatos Ortopédicos , Tenotomía/métodos , Tenotomía/tendencias
6.
Br J Sports Med ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38904119

RESUMEN

OBJECTIVES: To assess whether radial extracorporeal shock wave therapy (rESWT), sham-rESWT or a standardised exercise programme in combination with advice plus customised foot orthoses is more effective than advice plus customised foot orthoses alone in alleviating heel pain in patients with plantar fasciopathy. METHODS: 200 patients with plantar fasciopathy were included in a four-arm, parallel-group, sham-controlled, observer-blinded, partly patient-blinded trial. At baseline, before randomisation, all patients received advice plus customised foot orthoses. Patients were randomised to rESWT (n=50), sham-rESWT (n=50), exercise (n=50) or advice plus customised foot orthoses alone (n=50). Patients in the rESWT and sham-rESWT groups received three treatments. The exercise programme comprised two exercises performed three times a week for 12 weeks, including eight supervised sessions with a physiotherapist. Patients allocated to advice plus customised foot orthoses did not receive additional treatment. The primary outcome was change in heel pain during activity in the previous week per Numeric Rating Scale (0-10) from baseline to 6-month follow-up. The outcome was collected at baseline, and 3, 6 and 12 months. RESULTS: The primary analysis showed no statistically significant between-group differences in mean change in heel pain during activity for rESWT versus advice plus customised foot orthoses (-0.02, 95% CI -1.01 to 0.96), sham-rESWT versus advice plus customised foot orthoses (0.52, 95% CI -0.49 to 1.53) and exercise versus advice plus customised foot orthoses (-0.11, 95% CI -1.11 to 0.89) at 6 months. CONCLUSION: In patients with plantar fasciopathy, there was no additional benefit of rESWT, sham-rESWT or a standardised exercise programme over advice plus customised foot orthoses in alleviating heel pain. TRIAL REGISTRATION NUMBER: NCT03472989.

7.
J Neuroeng Rehabil ; 21(1): 105, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38907255

RESUMEN

BACKGROUND: The ankle is usually highly effective in modulating the swing foot's trajectory to ensure safe ground clearance but there are few reports of ankle kinetics and mechanical energy exchange during the gait cycle swing phase. Previous work has investigated ankle swing mechanics during normal walking but with developments in devices providing dorsiflexion assistance, it is now essential to understand the minimal kinetic requirements for increasing ankle dorsiflexion, particularly for devices employing energy harvesting or utilizing lighter and lower power energy sources or actuators. METHODS: Using a real-time treadmill-walking biofeedback technique, swing phase ankle dorsiflexion was experimentally controlled to increase foot-ground clearance by 4 cm achieved via increased ankle dorsiflexion. Swing phase ankle moments and dorsiflexor muscle forces were estimated using AnyBody modeling system. It was hypothesized that increasing foot-ground clearance by 4 cm, employing only the ankle joint, would require significantly higher dorsiflexion moments and muscle forces than a normal walking control condition. RESULTS: Results did not confirm significantly increased ankle moments with augmented dorsiflexion, with 0.02 N.m/kg at toe-off reducing to zero by the end of swing. Tibialis Anterior muscle force incremented significantly from 2 to 4 N/kg after toe-off, due to coactivation with the Soleus. To ensure an additional 4 cm mid swing foot-ground clearance, an estimated additional 0.003 Joules/kg is required to be released immediately after toe-off. CONCLUSION: This study highlights the interplay between ankle moments, muscle forces, and energy demands during swing phase ankle dorsiflexion, offering insights for the design of ankle assistive technologies. External devices do not need to deliver significantly greater ankle moments to increase ankle dorsiflexion but, they should offer higher mechanical power to provide rapid bursts of energy to facilitate quick dorsiflexion transitions before reaching Minimum Foot Clearance event. Additionally, for ankle-related bio-inspired devices incorporating artificial muscles or humanoid robots that aim to replicate natural ankle biomechanics, the inclusion of supplementary Tibialis Anterior forces is crucial due to Tibialis Anterior and Soleus co-activation. These design strategies ensures that ankle assistive technologies are both effective and aligned with the biomechanical realities of human movement.


Asunto(s)
Articulación del Tobillo , Tobillo , Músculo Esquelético , Dispositivos de Autoayuda , Humanos , Fenómenos Biomecánicos , Masculino , Adulto , Femenino , Articulación del Tobillo/fisiología , Tobillo/fisiología , Músculo Esquelético/fisiología , Caminata/fisiología , Marcha/fisiología , Adulto Joven , Pie/fisiología , Diseño de Equipo , Biorretroalimentación Psicológica/instrumentación , Biorretroalimentación Psicológica/métodos , Cinética
8.
Sensors (Basel) ; 24(9)2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38733034

RESUMEN

INTRODUCTION: The choice of materials for covering plantar orthoses or wearable insoles is often based on their hardness, breathability, and moisture absorption capacity, although more due to professional preference than clear scientific criteria. An analysis of the thermal response to the use of these materials would provide information about their behavior; hence, the objective of this study was to assess the temperature of three lining materials with different characteristics. MATERIALS AND METHODS: The temperature of three materials for covering plantar orthoses was analyzed in a sample of 36 subjects (15 men and 21 women, aged 24.6 ± 8.2 years, mass 67.1 ± 13.6 kg, and height 1.7 ± 0.09 m). Temperature was measured before and after 3 h of use in clinical activities, using a polyethylene foam copolymer (PE), ethylene vinyl acetate (EVA), and PE-EVA copolymer foam insole with the use of a FLIR E60BX thermal camera. RESULTS: In the PE copolymer (material 1), temperature increases between 1.07 and 1.85 °C were found after activity, with these differences being statistically significant in all regions of interest (p < 0.001), except for the first toe (0.36 °C, p = 0.170). In the EVA foam (material 2) and the expansive foam of the PE-EVA copolymer (material 3), the temperatures were also significantly higher in all analyzed areas (p < 0.001), ranging between 1.49 and 2.73 °C for EVA and 0.58 and 2.16 °C for PE-EVA. The PE copolymer experienced lower overall overheating, and the area of the fifth metatarsal head underwent the greatest temperature increase, regardless of the material analyzed. CONCLUSIONS: PE foam lining materials, with lower density or an open-cell structure, would be preferred for controlling temperature rise in the lining/footbed interface and providing better thermal comfort for users. The area of the first toe was found to be the least overheated, while the fifth metatarsal head increased the most in temperature. This should be considered in the design of new wearables to avoid excessive temperatures due to the lining materials.


Asunto(s)
Ortesis del Pié , Temperatura , Humanos , Femenino , Masculino , Adulto , Adulto Joven , Polivinilos/química , Polietileno/química , Polímeros/química , Ensayo de Materiales
9.
Sensors (Basel) ; 24(5)2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38474907

RESUMEN

When a limb suffers a fracture, rupture, or dislocation, it is traditionally immobilized with plaster. This may induce discomfort in the patient, as well as excessive itching and sweating, which creates the growth of bacteria, leading to an unhygienic environment and difficulty in keeping the injury clean during treatment. Furthermore, if the plaster remains for a long period, it may cause lesions in the joints and ligaments. To overcome all of these disadvantages, orthoses have emerged as important medical devices to help patients in rehabilitation, as well as for self-care of deficiencies in clinics and daily life. Traditionally, these devices are produced manually, which is a time-consuming and error-prone method. From another point of view, it is possible to use imageology (X-ray or computed tomography) to scan the human body; a process that may help orthoses manufacturing but which induces radiation to the patient. To overcome this great disadvantage, several types of 3D scanners, without any kind of radiation, have emerged. This article describes the use of various types of scanners capable of digitizing the human body to produce custom orthoses. Studies have shown that photogrammetry is the most used and most suitable 3D scanner for the acquisition of the human body in 3D. With this evolution of technology, it is possible to decrease the scanning time and it will be possible to introduce this technology into clinical environment.


Asunto(s)
Fracturas Óseas , Aparatos Ortopédicos , Humanos , Tomografía Computarizada por Rayos X , Tecnología , Extremidades
10.
Sensors (Basel) ; 24(3)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38339681

RESUMEN

Gait event detection is essential for controlling an orthosis and assessing the patient's gait. In this study, patients wearing an electromechanical (EM) knee-ankle-foot orthosis (KAFO) with a single IMU embedded in the thigh were subjected to gait event detection. The algorithm detected four essential gait events (initial contact (IC), toe off (TO), opposite initial contact (OIC), and opposite toe off (OTO)) and determined important temporal gait parameters such as stance/swing time, symmetry, and single/double limb support. These gait events were evaluated through gait experiments using four force plates on healthy adults and a hemiplegic patient who wore a one-way clutch KAFO and a pneumatic cylinder KAFO. Results showed that the smallest error in gait event detection was found at IC, and the largest error rate was observed at opposite toe off (OTO) with an error rate of -2.8 ± 1.5% in the patient group. Errors in OTO detection resulted in the largest error in determining the single limb support of the patient with an error of 5.0 ± 1.5%. The present study would be beneficial for the real-time continuous monitoring of gait events and temporal gait parameters for persons with an EM KAFO.


Asunto(s)
Tobillo , Ortesis del Pié , Adulto , Humanos , Marcha , Aparatos Ortopédicos , Articulación del Tobillo , Muslo , Fenómenos Biomecánicos , Caminata
11.
Clin Rehabil ; 37(1): 72-85, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36004384

RESUMEN

OBJECTIVE: Elbow flexion contractures are common complications of neonatal brachial plexus palsy, but evidence on how to treat these contractures is weak. This study compared the treatment of elbow flexion contractures using a dynamic orthosis or serial circular casting. METHODS: A randomized controlled trial was conducted with one-year follow-up. Children with an elbow flexion contracture of ≥30° were treated with either a night-worn dynamic orthosis for one year or serial casting for four weeks followed by night splinting. For pragmatic reasons, some participants were included in an open part of this study, this group was also analyzed separately. Degree of contracture and goal attainment scaling was evaluated at baseline and after 8, 20 and 54 weeks. RESULTS: 55 patients were analyzed in this trial, 32 of whom were randomized to treatment. At one-year follow-up of the randomized group, both dynamic splinting (median -8.5°, interquartile range [IQR] -13.5, -5) and serial casting (median -11.0°, IQR -16, -5) resulted in significant reduction of contracture (P < 0.001). The reduction was significantly greater with serial casting in the first 20 weeks, but not at one-year follow-up (P = 0.683). In the entire cohort, the individual functional goals had been reached in 24 out of 32 cases (80%) of dynamic splinting and 18 out of 23 cases (82%) of serial casting, respectively. CONCLUSION: The dynamic night orthosis is comparable to serial casting for treating elbow flexion contractures in children with brachial plexus birth injury. We recommend selecting one of these treatment modalities in close consultation with parents and patients.


Asunto(s)
Contractura , Parálisis Neonatal del Plexo Braquial , Niño , Recién Nacido , Humanos , Codo , Resultado del Tratamiento , Aparatos Ortopédicos , Rango del Movimiento Articular
12.
BMC Musculoskelet Disord ; 24(1): 545, 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37400860

RESUMEN

BACKGROUND: Individuals with myelomeningocele (MMC) exhibit neurological deficits below the lesion level involving both motor and sensory functions. Ambulation and functional outcomes in patients offered orthotic management since childhood were investigated. METHODS: Physical function, physical activity, pain, and health status were assessed in a descriptive study. RESULTS: Of 59 adults with MMC, aged 18-33 years, 12 were in the community ambulation (Ca), 19 in the household ambulation (Ha), six in the non-functional (N-f), and 22 in the non-ambulation (N-a) groups. Orthoses were used by 78% (n = 46), i.e., by 10/12 in the Ca, 17/19 in the Ha, 6/6 in the N-f, and 13/22 in the N-a groups. In the ten-metre walking test, the non-orthosis group (NO) walked faster than those wearing ankle-foot orthoses (AFOs) or free-articulated knee-ankle-foot orthoses (KAFO-Fs), the Ca group faster than the Ha and N-f groups, and the Ha group faster than the N-f group. In the six-minute walking test, the Ca group walked farther than the Ha group. In the five times sit-to-stand test, the AFO and KAFO-F groups required longer than the NO group, and the KAFO-F group longer than the foot orthosis (FO) group. Lower extremity function with orthoses was higher in the FO than the AFO and KAFO-F groups, higher in the KAFO-F than the AFO group, and higher in the AFO group than in those using trunk-hip-knee-ankle-foot orthoses. Functional independence increased with ambulatory function. Time spent in physical recreation was higher in the Ha than the Ca and N-a groups. There were no differences between the ambulation groups in rated pain or reported health status. CONCLUSION: The physical function results in persons with MMC improve our understanding of this population's heterogeneity and shed light on the importance of individualized orthotic management. The similarities between the various ambulatory levels in physical activity, pain, and health status may mirror opportunities to achieve equal results regardless of disability level. A clinical implication of the study is that orthotic management is likely to be beneficial for the patient with MMC of which the majority used their orthoses for most time of the day.


Asunto(s)
Ortesis del Pié , Meningomielocele , Humanos , Adulto , Niño , Meningomielocele/complicaciones , Meningomielocele/terapia , Caminata , Aparatos Ortopédicos , Dolor , Estado de Salud , Marcha
13.
BMC Musculoskelet Disord ; 24(1): 16, 2023 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-36611153

RESUMEN

BACKGROUND: This systematic review and meta-analysis examined the effectiveness of orthoses for flexible flatfeet in terms of patient-reported outcomes in children and adults. METHODS: EMBASE, Medline (OvidSP), Web-of-Science, Scopus, CINAHL, Cochrane Central Register of Controlled Clinical Trials, i.e., Cochrane Central and Pubmed were searched to identify relevant studies since their inception up to February 2021. We included randomized controlled trials (RCT) and prospective studies in which patient reported outcomes at baseline and follow-up in an orthoses group were compared with a no orthoses or sham sole group. Methodological quality of the studies was assessed using the Revised Cochrane risk-of-bias tool for randomized trials (RoB 2) and the Risk Of Bias In Non-Randomized Studies of Interventions (ROBINS-I). A meta-analysis was performed where there were multiple studies with the same outcome measures, which was the case for the Visual Analogue Scale (VAS) for pain in adults. RESULTS: In total nine studies were included: four RCT in children (N = 353) and four RCT and one prospective study in adults (N = 268) were included. There was considerable heterogeneity between studies. A meta-analysis demonstrated that pain reduction between baseline and follow-up was significantly larger in the orthoses (N = 167) than in the control groups in adults (N = 157; - 4.76, 95% CI [- 9.46, - 0.06], p0.05). CONCLUSION: Due to heterogeneity in study designs, we cannot conclude that foot orthoses are useful for flexible flatfoot in children and adults. However, based on the meta-analysis orthoses might be useful in decreasing pain in adults. The authors did not receive support from any organization for the submitted work.


Asunto(s)
Pie Plano , Ortesis del Pié , Niño , Adulto , Humanos , Pie Plano/terapia , Dolor , Medición de Resultados Informados por el Paciente , Sesgo
14.
BMC Musculoskelet Disord ; 24(1): 443, 2023 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-37268928

RESUMEN

BACKGROUND: Cerebral palsy (CP) is an umbrella term where an injury to the immature brain affects muscle tone and motor control, posture, and at times, the ability to walk and stand. Orthoses can be used to improve or maintain function. Ankle-foot orthoses (AFOs) are the most frequently used orthoses in children with CP. However, how commonly AFOs are used by children and adolescents with CP is still unknown. The aims of this study were to investigate and describe the use of AFOs in children with CP in Sweden, Norway, Finland, Iceland, Scotland, and Denmark, and compare AFO use between countries and by gross motor function classification system (GMFCS) level, CP subtype, sex, and age. METHOD: Aggregated data on 8,928 participants in the national follow-up programs for CP for the respective countries were used. Finland does not have a national follow-up program for individuals with CP and therefore a study cohort was used instead. Use of AFOs were presented as percentages. Logistic regression models were used to compare the use of AFOs among countries adjusted for age, CP subtype, GMFCS level, and sex. RESULTS: The proportion of AFO use was highest in Scotland (57%; CI 54-59%) and lowest in Denmark (35%; CI 33-38%). After adjusting for GMFCS level, children in Denmark, Finland, and Iceland had statistically significantly lower odds of using AFOs whereas children in Norway and Scotland reported statistically significantly higher usage than Sweden. CONCLUSION: In this study, the use of AFOs in children with CP in countries with relatively similar healthcare systems, differed between countries, age, GMFCS level, and CP subtype. This indicates a lack of consensus as to which individuals benefit from using AFOs. Our findings present an important baseline for the future research and development of practical guidelines in terms of who stands to benefit from using AFOs.


Asunto(s)
Parálisis Cerebral , Ortesis del Pié , Adolescente , Niño , Humanos , Tobillo , Marcha/fisiología , Parálisis Cerebral/diagnóstico , Parálisis Cerebral/epidemiología , Parálisis Cerebral/terapia , Estudios Transversales , Europa (Continente)/epidemiología
15.
Br J Sports Med ; 57(13): 872-881, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36898768

RESUMEN

OBJECTIVE: To evaluate the effects of biomechanical foot-based interventions (eg, footwear, insoles, taping and bracing on the foot) on patellofemoral loads during walking, running or walking and running combined in adults with and without patellofemoral pain or osteoarthritis. DESIGN: Systematic review with meta-analysis. DATA SOURCES: MEDLINE, CINAHL, SPORTdiscus, Embase and CENTRAL. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: English-language studies that assessed effects of biomechanical foot-based interventions on peak patellofemoral joint loads, quantified by patellofemoral joint pressure, reaction force or knee flexion moment during gait, in people with or without patellofemoral pain or osteoarthritis. RESULTS: We identified 22 footwear and 11 insole studies (participant n=578). Pooled analyses indicated low-certainty evidence that minimalist footwear leads to a small reduction in peak patellofemoral joint loads compared with conventional footwear during running only (standardised mean difference (SMD) (95% CI) = -0.40 (-0.68 to -0.11)). Low-certainty evidence indicated that medial support insoles do not alter patellofemoral joint loads during walking (SMD (95% CI) = -0.08 (-0.42 to 0.27)) or running (SMD (95% CI) = 0.11 (-0.17 to 0.39)). Very low-certainty evidence indicated rocker-soled shoes have no effect on patellofemoral joint loads during walking and running combined (SMD (95% CI) = 0.37) (-0.06 to 0.79)). CONCLUSION: Minimalist footwear may reduce peak patellofemoral joint loads slightly compared with conventional footwear during running only. Medial support insoles may not alter patellofemoral joint loads during walking or running and the evidence is very uncertain about the effect of rocker-soled shoes during walking and running combined. Clinicians aiming to reduce patellofemoral joint loads during running in people with patellofemoral pain or osteoarthritis may consider minimalist footwear.


Asunto(s)
Ortesis del Pié , Osteoartritis , Articulación Patelofemoral , Síndrome de Dolor Patelofemoral , Humanos , Adulto , Síndrome de Dolor Patelofemoral/terapia , Extremidad Inferior , Zapatos , Fenómenos Biomecánicos
16.
J Neuroeng Rehabil ; 20(1): 103, 2023 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-37542335

RESUMEN

BACKGROUND: Active upper extremity (UE) assistive devices have the potential to restore independent functional movement in individuals with UE impairment due to neuromuscular diseases or injury-induced chronic weakness. Academically fabricated UE assistive devices are not usually optimized for activities of daily living (ADLs), whereas commercially available alternatives tend to lack flexibility in control and activation methods. Both options are typically difficult to don and doff and may be uncomfortable for extensive daily use due to their lack of personalization. To overcome these limitations, we have designed, developed, and clinically evaluated the NuroSleeve, an innovative user-centered UE hybrid orthosis. METHODS: This study introduces the design, implementation, and clinical evaluation of the NuroSleeve, a user-centered hybrid device that incorporates a lightweight, easy to don and doff 3D-printed motorized UE orthosis and a functional electrical stimulation (FES) component. Our primary goals are to develop a customized hybrid device that individuals with UE neuromuscular impairment can use to perform ADLs and to evaluate the benefits of incorporating the device into occupational therapy sessions. The trial is designed as a prospective, open-label, single-cohort feasibility study of eight-week sessions combined with at-home use of the device and implements an iterative device design process where feedback from participants and therapists informs design improvement cycles. RESULTS: All participants learned how to independently don, doff, and use the NuroSleeve in ADLs, both in clinical therapy and in their home environments. All participants showed improvements in their Canadian Occupational Performance Measure (COPM), which was the primary clinical trial outcome measure. Furthermore, participants and therapists provided valuable feedback to guide further development. CONCLUSIONS: Our results from non-clinical testing and clinical evaluation demonstrate that the NuroSleeve has met feasibility and safety goals and effectively improved independent voluntary function during ADLs. The study's encouraging preliminary findings indicate that the NuroSleeve has met its technical and clinical objectives while improving upon the limitations of the existing UE orthoses owing to its personalized and flexible approach to hardware and firmware design. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT04798378, https://clinicaltrials.gov/ct2/show/NCT04798378 , date of registration: March 15, 2021.


Asunto(s)
Actividades Cotidianas , Rehabilitación de Accidente Cerebrovascular , Humanos , Canadá , Aparatos Ortopédicos , Impresión Tridimensional , Estudios Prospectivos , Rehabilitación de Accidente Cerebrovascular/métodos , Extremidad Superior , Estudios de Factibilidad
17.
Sensors (Basel) ; 23(24)2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38139603

RESUMEN

This cross-sectional study, conducted at a tertiary care hospital's rehabilitation clinic, aimed to validate Short Physical Performance Battery (SPPB) results obtained through plantar pressure analysis using commercial smart insoles (SPPB-SI) and to compare these results to manually acquired results by an experienced examiner (SPPB-M). This study included 40 independent-walking inpatients and outpatients aged 50 or older. SPPB-SI and SPPB-M were administered concurrently, with the smart insoles providing plantar pressure data that were converted into time-pressure curves. Two interpreters assessed the curves, determining component completion times for the SPPB-SI scores. Among the 40 participants (mean age: 72.98, SD: 9.27), the mean total SPPB-SI score was 7.72 ± 2.50, and the mean total SPPB-M score was 7.95 ± 2.63. The time recordings and measured scores of each SPPB-SI component exhibited high reliability with inter- and intra-interpreter correlation coefficients of 0.9 and 0.8 or higher, respectively. The intraclass correlation coefficient between the total SPPB-SI and SPPB-M scores was 0.831 (p < 0.001), and that between the component scores of the two measurements ranged from 0.837 to 0.901 (p < 0.001). Consistent correlations with geriatric functional parameters were observed for both SPPB-SI and SPPB-M. This study underscores the potential of commercial smart insoles as reliable tools for conducting SPPB assessments.


Asunto(s)
Evaluación Geriátrica , Equilibrio Postural , Humanos , Anciano , Estudios Transversales , Reproducibilidad de los Resultados , Evaluación Geriátrica/métodos , Rendimiento Físico Funcional
18.
Sensors (Basel) ; 23(21)2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37960617

RESUMEN

There is some uncertainty regarding how foot orthoses (FO) affect the biomechanics of the lower extremities during running in non-injured individuals. This study aims to describe the behavior of the angular velocity of the foot in the stride cycle measured with a low-sampling-rate IMU device commonly used by podiatrists. Specific objectives were to determine if there are differences in angular velocity between the right and left foot and to determine the effect of foot orthoses (FO) on the 3D angular velocity of the foot during running. The sample was composed of 40 male adults (age: 43.0 ± 13.8 years, weight: 72.0 ± 5.5 kg, and height: 175.5 ± 7.0 cm), who were healthy and without any locomotor system alterations at the time of the test. All subjects use FO on a regular basis. The results show that there are significant differences in the transverse plane between feet, with greater differences in the right foot. Significant differences between FO and non-FO conditions were observed in the frontal and transverse planes on the left foot and in the sagittal and transverse planes on the right foot. FO decreases the velocity of the foot in dorsi-plantar flexion and abduction and increases the velocity in inversion. The kinematic changes in foot velocity occur between 30% and 60% of the complete cycle, and the FO reduces the velocity in abduction and dorsi-plantar flexion and increases the velocity in inversion-eversion, which facilitates the transition to the oscillating leg and with it the displacement of the center of mass. Quantifying possible asymmetries and assessing the effect of foot orthoses may aid in improving running mechanics and preventing injuries in individuals.


Asunto(s)
Ortesis del Pié , Carrera , Adulto , Humanos , Masculino , Persona de Mediana Edad , Extremidad Inferior , Fenómenos Biomecánicos
19.
Sensors (Basel) ; 24(1)2023 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-38203110

RESUMEN

Lower limb exoskeletons and orthoses have been increasingly used to assist the user during gait rehabilitation through torque transmission and motor stability. However, the physical human-robot interface (HRi) has not been properly addressed. Current orthoses lead to spurious forces at the HRi that cause adverse effects and high abandonment rates. This study aims to assess and compare, in a holistic approach, human-robot joint misalignment and gait kinematics in three fixation designs of ankle-foot orthoses (AFOs). These are AFOs with a frontal shin guard (F-AFO), lateral shin guard (L-AFO), and the ankle modulus of the H2 exoskeleton (H2-AFO). An experimental protocol was implemented to assess misalignment, fixation displacement, pressure interactions, user-perceived comfort, and gait kinematics during walking with the three AFOs. The F-AFO showed reduced vertical misalignment (peak of 1.37 ± 0.90 cm, p-value < 0.05), interactions (median pressures of 0.39-3.12 kPa), and higher user-perceived comfort (p-value < 0.05) when compared to H2-AFO (peak misalignment of 2.95 ± 0.64 and pressures ranging from 3.19 to 19.78 kPa). F-AFO also improves the L-AFO in pressure (median pressures ranging from 8.64 to 10.83 kPa) and comfort (p-value < 0.05). All AFOs significantly modified hip joint angle regarding control gait (p-value < 0.01), while the H2-AFO also affected knee joint angle (p-value < 0.01) and gait spatiotemporal parameters (p-value < 0.05). Overall, findings indicate that an AFO with a frontal shin guard and a sports shoe is effective at reducing misalignment and pressure at the HRI, increasing comfort with slight changes in gait kinematics.


Asunto(s)
Ortesis del Pié , Robótica , Humanos , Fenómenos Biomecánicos , Tobillo , Marcha
20.
J Hand Ther ; 36(2): 479-485, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36470784

RESUMEN

We introduce a five-question decision-making tool for using relative motion in practice. The tool considers the primary aim of the relative motion orthosis, the amount of relative motion required and the number of fingers that should be included. The tool also helps clincians consider the person-specific characteristics that will impact the use of the orthoses, as well as, a variety of materials that could be used to fabricate the relative motion orthosis. Clinical examples demonstrate the use of the decision tool and illustrate the varied use of relative motion orthoses.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA