Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.385
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

2.
Eur Heart J ; 45(13): 1116-1124, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38321820

RESUMEN

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become a viable treatment option for patients with severe aortic valve stenosis across a broad range of surgical risk. The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize patients at lower surgical risk to TAVI or surgical aortic valve replacement (SAVR). The aim of the present study was to report clinical and bioprosthesis outcomes after 10 years. METHODS: The NOTION trial randomized 280 patients to TAVI with the self-expanding CoreValve (Medtronic Inc.) bioprosthesis (n = 145) or SAVR with a bioprosthesis (n = 135). The primary composite outcome was the risk of all-cause mortality, stroke, or myocardial infarction. Bioprosthetic valve dysfunction (BVD) was classified as structural valve deterioration (SVD), non-structural valve dysfunction (NSVD), clinical valve thrombosis, or endocarditis according to Valve Academic Research Consortium-3 criteria. Severe SVD was defined as (i) a transprosthetic gradient of 30 mmHg or more and an increase in transprosthetic gradient of 20 mmHg or more or (ii) severe new intraprosthetic regurgitation. Bioprosthetic valve failure (BVF) was defined as the composite rate of death from a valve-related cause or an unexplained death following the diagnosis of BVD, aortic valve re-intervention, or severe SVD. RESULTS: Baseline characteristics were similar between TAVI and SAVR: age 79.2 ± 4.9 years and 79.0 ± 4.7 years (P = .7), male 52.6% and 53.8% (P = .8), and Society of Thoracic Surgeons score < 4% of 83.4% and 80.0% (P = .5), respectively. After 10 years, the risk of the composite outcome all-cause mortality, stroke, or myocardial infarction was 65.5% after TAVI and 65.5% after SAVR [hazard ratio (HR) 1.0; 95% confidence interval (CI) 0.7-1.3; P = .9], with no difference for each individual outcome. Severe SVD had occurred in 1.5% and 10.0% (HR 0.2; 95% CI 0.04-0.7; P = .02) after TAVI and SAVR, respectively. The cumulative incidence for severe NSVD was 20.5% and 43.0% (P < .001) and for endocarditis 7.2% and 7.4% (P = 1.0) after TAVI and SAVR, respectively. No patients had clinical valve thrombosis. Bioprosthetic valve failure occurred in 9.7% of TAVI and 13.8% of SAVR patients (HR 0.7; 95% CI 0.4-1.5; P = .4). CONCLUSIONS: In patients with severe AS and lower surgical risk randomized to TAVI or SAVR, the risk of major clinical outcomes was not different 10 years after treatment. The risk of severe bioprosthesis SVD was lower after TAVR compared with SAVR, while the risk of BVF was similar.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Infarto del Miocardio , Accidente Cerebrovascular , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Infarto del Miocardio/etiología , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Endocarditis/cirugía , Trombosis/etiología
3.
Eur Heart J ; 45(11): 876-894, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38426859

RESUMEN

Transcatheter tricuspid valve interventions (TTVI) are emerging as alternatives to surgery in high-risk patients with isolated or concomitant tricuspid regurgitation. The development of new minimally invasive solutions potentially more adapted to this largely undertreated population of patients, has fuelled the interest for the tricuspid valve. Growing evidence and new concepts have contributed to revise obsolete and misleading perceptions around the right side of the heart. New definitions, classifications, and a better understanding of the disease pathophysiology and phenotypes, as well as their associated patient journeys have profoundly and durably changed the landscape of tricuspid disease. A number of registries and a recent randomized controlled pivotal trial provide preliminary guidance for decision-making. TTVI seem to be very safe and effective in selected patients, although clinical benefits beyond improved quality of life remain to be demonstrated. Even if more efforts are needed, increased disease awareness is gaining momentum in the community and supports the establishment of dedicated expert valve centres. This review is summarizing the achievements in the field and provides perspectives for a less invasive management of a no-more-forgotten disease.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Calidad de Vida , Cateterismo Cardíaco/efectos adversos , Insuficiencia de la Válvula Tricúspide/etiología , Resultado del Tratamiento
4.
Eur Heart J ; 45(21): 1890-1900, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38270189

RESUMEN

BACKGROUND AND AIMS: In transcatheter aortic valve replacement (TAVR) recipients, the optimal management of concomitant chronic obstructive coronary artery disease (CAD) remains unknown. Some advocate for pre-TAVR percutaneous coronary intervention, while others manage it expectantly. The aim of this study was to assess the impact of varying degrees and extent of untreated chronic obstructive CAD on TAVR and longer-term outcomes. METHODS: The authors conducted a retrospective cohort study of TAVR recipients from January 2015 to November 2021, separating patients into stable non-obstructive or varying degrees of obstructive CAD. The major outcomes of interest were procedural all-cause mortality and complications, major adverse cardiovascular events, and post-TAVR unplanned coronary revascularization. RESULTS: Of the 1911 patients meeting inclusion, 75%, 6%, 10%, and 9% had non-obstructive, intermediate-risk, high-risk, and extreme-risk CAD, respectively. Procedural complication rates overall were low (death 0.4%, shock 0.1%, extracorporeal membrane oxygenation 0.1%), with no difference across groups. At a median follow-up of 21 months, rates of acute coronary syndrome and unplanned coronary revascularization were 0.7% and 0.5%, respectively, in the non-obstructive population, rising in incidence with increasing severity of CAD (P < .001 for acute coronary syndrome/unplanned coronary revascularization). Multivariable analysis did not yield a significantly greater risk of all-cause mortality or major adverse cardiovascular events across groups. One-year acute coronary syndrome and unplanned coronary revascularization rates in time-to-event analyses were significantly greater in the non-obstructive (98%) vs. obstructive (94%) subsets (Plog-rank< .001). CONCLUSIONS: Transcatheter aortic valve replacement can be performed safely in patients with untreated chronic obstructive CAD, without portending higher procedural complication rates and with relatively low rates of unplanned coronary revascularization and acute coronary syndrome at 1 year.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano , Intervención Coronaria Percutánea , Resultado del Tratamiento , Factores de Riesgo
5.
Eur Heart J ; 45(13): 1104-1115, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38366821

RESUMEN

Research performed in Europe has driven cardiovascular device innovation. This includes, but is not limited to, percutaneous coronary intervention, cardiac imaging, transcatheter heart valve implantation, and device therapy of cardiac arrhythmias and heart failure. An important part of future medical progress involves the evolution of medical technology and the ongoing development of artificial intelligence and machine learning. There is a need to foster an environment conducive to medical technology development and validation so that Europe can continue to play a major role in device innovation while providing high standards of safety. This paper summarizes viewpoints on the topic of device innovation in cardiovascular medicine at the European Society of Cardiology Cardiovascular Round Table, a strategic forum for high-level dialogue to discuss issues related to the future of cardiovascular health in Europe. Devices are developed and improved through an iterative process throughout their lifecycle. Early feasibility studies demonstrate proof of concept and help to optimize the design of a device. If successful, this should ideally be followed by randomized clinical trials comparing novel devices vs. accepted standards of care when available and the collection of post-market real-world evidence through registries. Unfortunately, standardized procedures for feasibility studies across various device categories have not yet been implemented in Europe. Cardiovascular imaging can be used to diagnose and characterize patients for interventions to improve procedural results and to monitor devices long term after implantation. Randomized clinical trials often use cardiac imaging-based inclusion criteria, while less frequently trials randomize patients to compare the diagnostic or prognostic value of different modalities. Applications using machine learning are increasingly important, but specific regulatory standards and pathways remain in development in both Europe and the USA. Standards are also needed for smart devices and digital technologies that support device-driven biomonitoring. Changes in device regulation introduced by the European Union aim to improve clinical evidence, transparency, and safety, but they may impact the speed of innovation, access, and availability. Device development programmes including dialogue on unmet needs and advice on study designs must be driven by a community of physicians, trialists, patients, regulators, payers, and industry to ensure that patients have access to innovative care.


Asunto(s)
Cardiología , Procedimientos Quirúrgicos Torácicos , Humanos , Inteligencia Artificial , Diagnóstico por Imagen , Técnicas de Imagen Cardíaca
6.
Eur Heart J ; 45(11): 895-911, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38441886

RESUMEN

Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia
7.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-38820201

RESUMEN

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Asunto(s)
Endocarditis , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/mortalidad , Endocarditis/cirugía , Endocarditis/mortalidad , Remoción de Dispositivos , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Resultado del Tratamiento , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
8.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38554125

RESUMEN

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Asunto(s)
Estenosis de la Válvula Aórtica , Benchmarking , Tiempo de Internación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Masculino , Femenino , Anciano de 80 o más Años , Tiempo de Internación/estadística & datos numéricos , Anciano , Vías Clínicas , Europa (Continente)/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Seguridad del Paciente
9.
Am Heart J ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39121916

RESUMEN

BACKGROUND: About half of patients with severe aortic stenosis present with concomitant coronary artery disease. The optimal timing of percutaneous coronary intervention (PCI) and transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and concomitant coronary artery disease remains unknown. STUDY DESIGN: The TAVI PCI trial is a prospective, international, multicenter, randomized, two-arm, open-label study planning to enroll a total of 986 patients. It is designed to investigate whether the strategy "angiography-guided complete revascularization after (within 1-45 days) TAVI" is non-inferior to the strategy "angiography-guided complete revascularization before (within 1-45 days) TAVI" using the Edwards SAPIEN 3 or 3 Ultra Transcatheter Heart Valve™ in patients with severe aortic stenosis and concomitant coronary artery disease. Patients are randomized in a 1:1 ratio to one of the two treatment strategies. The primary end point is a composite of all-cause death, non-fatal myocardial infarction, ischemia-driven revascularization, rehospitalization (valve- or procedure-related including heart failure), or life-threatening/disabling or major bleeding at 1 year. CONCLUSIONS: The TAVI PCI trial tests the hypothesis that the strategy "PCI after TAVI" is non-inferior to the strategy "PCI before TAVI" in patients with severe aortic stenosis and concomitant coronary artery disease.

10.
J Pediatr ; 271: 114052, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38615941

RESUMEN

OBJECTIVE: To evaluate postprocedural clinical characteristics of preterm infants undergoing transcatheter patent ductus arteriosus (PDA) closure, including oxygenation/ventilation failure and cardiovascular compromise. STUDY DESIGN: Multicenter retrospective cohort study of preterm infants who were ≤2 kg at the time of percutaneous PDA closure between August 2018 and July 2021. Indices of cardiorespiratory stability were collected pre-closure, immediately post-closure, and subsequently averaged every 4 hours for the first 24 hours post-procedure. The primary outcome was incidence of post-transcatheter cardiorespiratory syndrome: composite of hemodynamic instability (defined by systemic hypotension, systemic hypertension, or use of new inotropes/vasopressors in the first 24 hours after catheterization) and at least one of the following: (i) ventilation failure or (ii) oxygenation failure. RESULTS: A total of 197 patients were included with a median [IQR] age and weight at catheterization of 34 [25, 43] days and 1090 [900, 1367] grams, respectively. The primary composite outcome of post-transcatheter cardiorespiratory syndrome was reported in 46 (23.3%). CONCLUSION: Post-transcatheter cardiorespiratory syndrome is characterized primarily by systemic hypertension and oxygenation failure, with a very low incidence of hypotension and need for inotropes.


Asunto(s)
Cateterismo Cardíaco , Conducto Arterioso Permeable , Recien Nacido Prematuro , Complicaciones Posoperatorias , Humanos , Conducto Arterioso Permeable/cirugía , Estudios Retrospectivos , Masculino , Femenino , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Recién Nacido , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Lactante , Estudios de Cohortes
11.
J Cardiovasc Electrophysiol ; 35(3): 488-497, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38254339

RESUMEN

Transcatheter aortic valve replacement (TAVR) often leads to conduction abnormalities, necessitating pacemaker implantation. This review of 38 meta-analyses identified preexisting right bundle branch block (RBBB), LAHB, and new-onset left bundle branch block as key risk factors, with a higher PPM risk in male and older patients. Procedural factors like transfemoral access and self-expandable valves also increase this risk. Prevention focuses on tailoring TAVR to individual electrophysiological and anatomical profiles. However, there's a lack of consensus in managing these conduction disturbances post-TAVR, highlighting the need for further research and standardized treatment strategies.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Marcapaso Artificial/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/prevención & control , Válvula Aórtica/cirugía
12.
Cardiovasc Diabetol ; 23(1): 73, 2024 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-38365751

RESUMEN

BACKGROUND: Stress hyperglycemia ratio (SHR) has recently been recognized as a novel biomarker that accurately reflects acute hyperglycemia status and is associated with poor prognosis of heart failure. We evaluated the relationship between SHR and clinical outcomes in patients with severe aortic stenosis receiving transcatheter aortic valve replacement (TAVR). METHODS: There were 582 patients with severe native aortic stenosis who underwent TAVR consecutively enrolled in the study. The formula used to determine SHR was as follows: admission blood glucose (mmol/L)/(1.59×HbA1c[%]-2.59). The primary endpoint was defined as all-cause mortality, while secondary endpoints included a composite of cardiovascular mortality or readmission for heart failure, and major adverse cardiovascular events (MACE) including cardiovascular mortality, non-fatal myocardial infarction, and non-fatal stroke. Multivariable Cox regression and restricted cubic spline analysis were employed to assess the relationship between SHR and endpoints, with hazard ratios (HRs) and 95% confidence intervals (CIs). RESULTS: During a median follow-up of 3.9 years, a total of 130 cases (22.3%) of all-cause mortality were recorded. Results from the restricted cubic spline analysis indicated a linear association between SHR and all endpoints (p for non-linearity > 0.05), even after adjustment for other confounding factors. Per 0.1 unit increase in SHR was associated with a 12% (adjusted HR: 1.12, 95% CI: 1.04-1.21) higher incidence of the primary endpoint, a 12% (adjusted HR: 1.12, 95% CI: 1.02-1.22) higher incidence of cardiovascular mortality or readmission for heart failure, and a 12% (adjusted HR: 1.12, 95% CI: 1.01-1.23) higher incidence of MACE. Subgroup analysis revealed that SHR had a significant interaction with diabetes mellitus with regard to the risk of all-cause mortality (p for interaction: 0.042). Kaplan-Meier survival analysis showed that there were significant differences in the incidence of all endpoints between the two groups with 0.944 as the optimal binary cutoff point of SHR (all log-rank test: p < 0.05). CONCLUSIONS: Our study indicates linear relationships of SHR with the risk of all-cause mortality, cardiovascular mortality or readmission for heart failure, and MACE in patients with severe aortic stenosis receiving TAVR after a median follow-up of 3.9 years. Patients with an SHR exceeding 0.944 had a poorer prognosis compared to those with lower SHR values.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Hiperglucemia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Pronóstico , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Hiperglucemia/diagnóstico , Factores de Riesgo
13.
Cardiovasc Diabetol ; 23(1): 260, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39026315

RESUMEN

BACKGROUND: Type I and type II diabetes mellitus (DM) patients have a higher prevalence of cardiovascular diseases, as well as a higher mortality risk of cardiovascular diseases and interventions. This study provides an update on the impact of DM on clinical outcomes, including mortality, complications and reinterventions, using data on percutaneous and surgical cardiac interventions in the Netherlands. METHODS: This is a retrospective, nearby nationwide study using real-world observational data registered by the Netherlands Heart Registration (NHR) between 2015 and 2020. Patients treated for combined or isolated coronary artery disease (CAD) and aortic valve disease (AVD) were studied. Bivariate analyses and multivariate logistic regression models were used to evaluate the association between DM and clinical outcomes both unadjusted and adjusted for baseline characteristics. RESULTS: 241,360 patients underwent the following interventions; percutaneous coronary intervention(N = 177,556), coronary artery bypass grafting(N = 39,069), transcatheter aortic valve implantation(N = 11,819), aortic valve replacement(N = 8,028) and combined CABG and AVR(N = 4,888). The incidence of DM type I and II was 21.1%, 26.7%, 17.8%, 27.6% and 27% respectively. For all procedures, there are statistically significant differences between patients living with and without diabetes, adjusted for baseline characteristics, at the expense of patients with diabetes for 30-days mortality after PCI (OR = 1.68; p <.001); 120-days mortality after CABG (OR = 1.35; p <.001), AVR (OR = 1.5; p <.03) and CABG + AVR (OR = 1.42; p =.02); and 1-year mortality after CABG (OR = 1.43; p <.001), TAVI (OR = 1.21; p =.01) and PCI (OR = 1.68; p <.001). CONCLUSION: Patients with DM remain to have unfavourable outcomes compared to nondiabetic patients which calls for a critical reappraisal of existing care pathways aimed at diabetic patients within the cardiovascular field.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Intervención Coronaria Percutánea , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Estudios Retrospectivos , Resultado del Tratamiento , Intervención Coronaria Percutánea/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Factores de Tiempo , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/cirugía , Persona de Mediana Edad , Medición de Riesgo , Anciano de 80 o más Años , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Países Bajos/epidemiología , Diabetes Mellitus Tipo 2/mortalidad , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Diabetes Mellitus Tipo 1/mortalidad , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/terapia , Incidencia , Enfermedad de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica/mortalidad , Complicaciones Posoperatorias/mortalidad , Hospitales de Alto Volumen
14.
Eur J Clin Invest ; 54(9): e14241, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38767226

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas , Falla de Prótesis , Masculino , Anciano
15.
Eur J Clin Invest ; : e14274, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38925546

RESUMEN

BACKGROUND: Invasive coronary angiography (ICA) is the standard for pre-procedural assessment of coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI). However, it requires hospitalization and can be associated with complications. Computed tomography angiography (CTA) may be a viable alternative to rule out prognostically relevant CAD. METHODS: The EASE-IT CT Registry is an investigator-initiated, prospective, observational, multicentre pilot registry involving patients aged ≥75 years with severe aortic stenosis (AS) intended to implant a transcatheter heart valve (THV) of the SAPIEN family. A total of 150 patients will be recruited from four sites in Germany and Austria. The registry will consist of two prospective cohorts: the investigational CTA-only cohort and the CTA + ICA control cohort. The CTA-only cohort will enrol 100 patients in whom significant (≥50%) left main (LM) and/or proximal left anterior descending artery (LAD) stenosis are ruled out on CTA. The CTA + ICA control cohort will enrol 50 patients who have undergone both CTA and ICA before TAVI and in whom ≥50% LM/proximal LAD stenosis has been ruled out by CTA. Three composite endpoints will be assessed at 3 months post-TAVI: CAD-specific endpoints, VARC-3-defined device success and early safety. CONCLUSION: The EASE-IT CT Registry evaluates whether TAVI can be carried out safely without performing ICA if prognostically relevant CAD of the LM/proximal LAD is ruled out with CTA. If so, the omission of ICA would help streamline the pre-procedural workup of TAVI patients.

16.
Rev Cardiovasc Med ; 25(4): 134, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-39076562

RESUMEN

The intricate interplay between mitral regurgitation (MR) and left ventricular outflow tract (LVOT) obstruction may result in two clinical scenarios: prosthesis-related LVOT obstruction after mitral valve replacement (TMVR) and systolic anterior motion (SAM)-associated MR. This review provides a comprehensive overview of the pathophysiology, risk assessment, and transcatheter interventions for mitigating the likelihood of LVOT obstruction in patients undergoing TMVR. In addition, it extends its focus to SAM-associated MR, elucidating the different aetiological mechanisms contributing to this phenomenon, beyond hypertrophic cardiomyopathy. Transcatheter treatment options, are explored as potential therapeutic strategies, offering insights into their hemodynamic effectiveness and limitations.

17.
Rev Cardiovasc Med ; 25(3): 99, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-39076950

RESUMEN

Treatment decisions in the context of severe aortic stenosis (AS) associated with other valvular heart diseases (VHDs) have become a major challenge in recent years. Transcatheter aortic valve replacement (TAVR) in AS has increased significantly in younger patients with lower surgical risk, which has complicated the choice of the best treatment in cases of other associated valvulopathies. The most frequently associated lesions in this clinical scenario are mitral regurgitation (MR), mitral stenosis, and tricuspid regurgitation (TR). Furthermore, it should be noted that different percutaneous techniques are now available to accommodate any associated valvulopathies, which has considerably broadened the range of therapeutic options. The management of AS treated in isolation, especially by TAVR, has also shown that many cases of significant MR or TR are substantially reduced without any intervention. However, although some parameters have been described as potential risk factors in predicting the poor outcome of untreated VHDs, which cases will progress in a clinically more aggressive way remains uncertain. This review aimed to evaluate the most recent publications to provide the pathophysiology and prognosis of severe AS associated with other significant VHDs and to evaluate the best invasive therapeutic approach depending on the associated valvular disease.

18.
Rev Cardiovasc Med ; 25(1): 3, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39077657

RESUMEN

Background: Transcatheter aortic valve replacement (TAVR) has become the dominant treatment for aortic valve disease. While TAVR safety has improved over time, concern remains over the occurrence of cerebrovascular accidents (CVA) secondary to device placement, which is associated with increased morbidity and mortality. The Sentinel Cerebral Protection System (CPS) was developed to reduce the risk of embolic strokes associated with debris produced during TAVR. Studies evaluating Sentinel CPS efficacy have produced conflicting results, and there is little understanding of which patients are selected for device placement in "real-world" settings. With no existing guidelines on device use, the purpose of this study was to describe and compare the characteristics of patients who receive CPS with those who do not in a "real-world" setting of consecutive TAVR patients and evaluate its impact on postoperative complications, namely stroke. Methods: This was a single-center, retrospective study of all patients undergoing TAVR between July 1, 2019, and December 31, 2020. Patient demographics, baseline, and perioperative characteristics were collected prospectively using the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapy (TVT) Registry and our institution's TAVR database for analysis. Postoperative outcomes were assessed using primary endpoints of in-hospital/30-day stroke and the composite of death, stroke, and bleeding/vascular events at one-year. To adjust for baseline differences, a propensity score was developed including all factors that were different between groups, and Multivariate Cox Regression analysis was used to control for these differences. Patient follow-up was 97% complete at 12 months with 100% echocardiographic follow-up. Results: A total of 242 consecutive patients (57.9% male) were analyzed, with a mean age of 79.9 ± 9 years. Of these patients, 134 (55.4%) received the Sentinel CPS and 108 (44.6%) did not. Sentinel CPS patients were more likely to be male, not on dialysis, without prior CVA or pacemaker, had less severe chronic lung disease, and were lower operative risk compared to concurrent non-CPS patients. CPS patients were also found to have higher hemoglobin and albumin levels, lower creatinine, and were less likely to be on immunosuppressant therapy. The incidence of in-hospital/30-day stroke after TAVR did not differ between CPS and non-CPS patients (0.0% vs. 1.9%; p = 0.198). Unadjusted analyses at one-year showed a lower occurrence of the composite endpoint in CPS patients compared non-CPS patients (8.3% vs. 17.0%; p = 0.034). After adjustment, the hazard ratio (Adj HR) for the CPS group was no longer significantly associated with a lower composite endpoint (Adj HR = 0.609, 95% CI 0.244-1.523; p = 0.289). Both unadjusted (p = 0.233) and adjusted (p = 0.132) analyses showed no difference in the incidence of stroke at one-year. Conclusions: Our study demonstrates that in a "real-world" setting, the Sentinel CPS device is more likely to be used in healthier and less complex patients. In analyses adjusted for illness severity and patient complexity, CPS use did not have a significant effect on the incidence of in-hospital/30-day stroke or the composite endpoint of death, stroke, and bleeding/vascular events at one-year.

19.
Rev Cardiovasc Med ; 25(2): 60, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39077340

RESUMEN

Interventions in structural heart disease cover many catheter-based procedures for congenital and acquired conditions including valvular diseases, septal defects, arterial or venous obstructions, and fistulas. Among the available procedures, the most common are aortic valve implantation, mitral or tricuspid valve repair/implantation, left atrial appendage occlusion, and patent foramen ovale closure. Antithrombotic therapy for transcatheter structural heart disease interventions aims to prevent thromboembolic events and reduce the risk of short-term and long-term complications. The specific approach to antithrombotic therapy depends on the type of intervention and individual patient factors. In this review, we synopsize contemporary evidence on antithrombotic therapies for structural heart disease interventions and highlight the importance of a personalized approach. These recommendations may evolve over time as new evidence emerges and clinical guidelines are updated. Therefore, it's crucial for healthcare professionals to stay updated on the most recent guidelines and individualize therapy based on patient-specific factors and procedural considerations.

20.
BMC Cancer ; 24(1): 620, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38773564

RESUMEN

BACKGROUND: The role of adjuvant transcatheter arterial chemoembolization (TACE) following repeated resection/ablation for recurrent hepatocellular carcinoma (HCC) remains uncertain. The aim of this study was to assess the effectiveness of adjuvant TACE following repeated resection or ablation in patients with early recurrent HCC. METHODS: Information for patients who underwent repeated surgery or radiofrequency ablation (RFA) for early recurrent HCCs (< 2 years) at our institution from January 2017 to December 2020 were collected. Patients were divided into adjuvant TACE and observation groups according to whether they received adjuvant TACE or not. The recurrence-free survival (RFS) and overall survival (OS) were compared between the two groups before and after propensity score matching (PSM). RESULTS: Of the 225 patients enrolled, the median time of HCC recurrence was 11 months (IQR, 6-16 months). After repeated surgery or radiofrequency ablation (RFA) for recurrent tumors, 45 patients (20%) received adjuvant TACE while the remaining 180 (80%) didn't. There were no significant differences in RFS (P = 0.325) and OS (P = 0.072) between adjuvant TACE and observation groups before PSM. There were also no significant differences in RFS (P = 0.897) and OS (P = 0.090) between the two groups after PSM. Multivariable analysis suggested that multiple tumors, liver cirrhosis, and RFA were independent risk factors for the re-recurrence of HCC. CONCLUSION: Adjuvant TACE after repeated resection or ablation for early recurrent HCCs was not associated with a long-term survival benefit in this single-center cohort.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Hepatectomía , Neoplasias Hepáticas , Recurrencia Local de Neoplasia , Puntaje de Propensión , Humanos , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Quimioembolización Terapéutica/métodos , Masculino , Femenino , Persona de Mediana Edad , Hepatectomía/métodos , Anciano , Ablación por Radiofrecuencia/métodos , Estudios Retrospectivos , Terapia Combinada , Resultado del Tratamiento , Quimioterapia Adyuvante/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA