RESUMEN
OBJECTIVES: To study intrathecal kappa free light chain (KFLC) synthesis in people living with HIV (PLWH) in comparison with multiple sclerosis (MS). METHODS: Cross-sectional analysis including 56 untreated and 150 well treated PLWH, and compared with 58 controls, and 223 MS patients. RESULTS: Elevated serum/cerebrospinal fluid (CSF) IgG and KFLC indices were observed in untreated PLWH. Seventy percent of untreated PLWH had KFLC index above 6.1, a threshold associated with clinically isolated syndrome/MS diagnosis. No association was found between KFCL index and CSF markers of neuronal injury in either PLWH or MS patients. CONCLUSIONS: HIV-related immune system dysfunction is often associated with an elevated KFLC index akin to those observed in MS. HIV infection should be considered as a differential diagnosis for patients presenting with neurological symptoms and increased intrathecal immunoglobulin synthesis.
Asunto(s)
Infecciones por VIH , Inmunoglobulina G , Cadenas kappa de Inmunoglobulina , Esclerosis Múltiple , Humanos , Esclerosis Múltiple/líquido cefalorraquídeo , Esclerosis Múltiple/sangre , Masculino , Femenino , Inmunoglobulina G/sangre , Inmunoglobulina G/líquido cefalorraquídeo , Infecciones por VIH/complicaciones , Infecciones por VIH/sangre , Infecciones por VIH/líquido cefalorraquídeo , Adulto , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/sangre , Estudios Transversales , Persona de Mediana EdadRESUMEN
The diagnosis of MS relies on a combination of imaging, clinical examinations, and biological analyses, including blood and cerebrospinal fluid (CSF) assessments. G-Oligoclonal bands (OCBs) are considered a "gold standard" for MS diagnosis due to their high sensitivity and specificity. Recent advancements have involved the introduced of kappa free light chain (k-FLC) assay into cerebrospinal fluid (CSF) and serum (S), along with the albumin quotient, leading to the development of a novel biomarker known as the "K-index" or "k-FLC index". The use of the K-index has been recommended to decrease costs, increase laboratory efficiency, and to skip potential subjective operator-dependent risk that could happen during the identification of OCBs profiles. This review aims to provide a comprehensive overview and analysis of recent scientific articles, focusing on updated methods for MS diagnosis with an emphasis on the utility of the K-index. Numerous studies indicate that the K-index demonstrates high sensitivity and specificity, often comparable to or surpassing the diagnostic accuracy of OCBs evaluation. The integration of the measure of the K-index with OCBs assessment emerges as a more precise method for MS diagnosis. This combined approach not only enhances diagnostic accuracy, but also offers a more efficient and cost-effective alternative.
Asunto(s)
Biomarcadores , Humanos , Bandas Oligoclonales/líquido cefalorraquídeo , Bandas Oligoclonales/sangre , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/líquido cefalorraquídeo , Esclerosis Múltiple/sangre , Sensibilidad y Especificidad , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/sangreRESUMEN
Cerebrospinal fluid (CSF) analysis is of utmost importance for diagnosis and differential diagnosis of patients with suspected multiple sclerosis (MS). Evidence of intrathecal immunoglobulin G (IgG) synthesis proves the inflammatory nature of the disease, increases diagnostic certainty and substitutes for dissemination in time according to current diagnostic criteria. The gold standard to determine intrathecal IgG synthesis is the detection of CSF-restricted oligoclonal bands (OCBs). However, advances in laboratory methods brought up κ-free light chains (FLCs) as a new biomarker, which are produced in excess over intact immunoglobulins and accumulate in CSF in the case of central nervous system-derived inflammation. Overwhelming evidence showed a high diagnostic accuracy of intrathecal κ-FLC synthesis in MS with sensitivity and specificity of approximately 90% similar to OCB. κ-FLCs have advantages as its detection is fast, easy, cost-effective, reliable, rater-independent and returning quantitative results which might also improve the value of predicting MS disease activity. An international panel of experts in MS and CSF diagnostics developed a consensus of all participants. Six recommendations are given for establishing standard CSF evaluation in patients suspected of having MS. The panel recommended to include intrathecal κ-FLC synthesis in the next revision of MS diagnostic criteria as an additional tool to measure intrathecal immunoglobulin synthesis.
Asunto(s)
Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Inmunoglobulina G/líquido cefalorraquídeo , Biomarcadores/líquido cefalorraquídeo , Sensibilidad y Especificidad , Bandas Oligoclonales/líquido cefalorraquídeoRESUMEN
BACKGROUND: Intrathecal immunoglobulin-G synthesis is a hallmark of multiple sclerosis (MS), which can be detected by oligoclonal IgG bands (OCB) or by κ-free light chains (κ-FLC) in cerebrospinal fluid. OBJECTIVE: To perform a systematic review and meta-analysis to evaluate whether κ-FLC index has similar diagnostic value to identify patients with clinically isolated syndrome (CIS) or MS compared to OCB, and to determine κ-FLC index cut-off. METHODS: PubMed was searched for studies that assessed diagnostic sensitivity and specificity of κ-FLC index and OCB to discriminate CIS/MS patients from control subjects. Two reviewers following preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines performed study eligibility assessment and data extraction. Findings from studies were analyzed with bivariate mixed models. RESULTS: A total of 32 studies were included in the meta-analysis to evaluate diagnostic value of κ-FLC index. Sensitivity and specificity ranged from 52% to 100% (weighted average: 88%) and 69% to 100% (89%) for κ-FLC index and from 37% to 100% (85%) and 74% to 100% (92%) for OCB. Mean difference of sensitivity and specificity between κ-FLC index and OCB was 2 and -4 percentage points. Diagnostic accuracy determined by mixed models revealed no significant difference between κ-FLC index and OCB. A discriminatory cut-off for κ-FLC index was determined at 6.1. CONCLUSION: The findings indicate that κ-FLC index has similar diagnostic accuracy in MS as OCB.
Asunto(s)
Enfermedades Desmielinizantes , Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Bandas Oligoclonales/líquido cefalorraquídeo , Inmunoglobulina G/líquido cefalorraquídeo , Biomarcadores/líquido cefalorraquídeoRESUMEN
Multiple sclerosis (MS) is a chronic immune-mediated disorder of the central nervous system that shows a high interindividual heterogeneity, which frequently poses challenges regarding diagnosis and prediction of disease activity. In this context, evidence of intrathecal inflammation provides an important information and might be captured by kappa free light chains (κ-FLC) in the cerebrospinal fluid (CSF). In this review, we provide an overview on what is currently known about κFLC, its historical development, the available assays and current evidence on its diagnostic and prognostic value in MS. Briefly, intrathecal κFLC synthesis reaches similar diagnostic accuracy compared to the well-established CSF-restricted oligoclonal bands (OCB) to identify patients with MS, and recent studies even depict its value for prediction of early MS disease activity. Furthermore, detection of κFLC has significant methodological advantages in comparison to OCB detection.
Asunto(s)
Esclerosis Múltiple , Bandas Oligoclonales , Humanos , Bandas Oligoclonales/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/líquido cefalorraquídeo , Cadenas Ligeras de Inmunoglobulina/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , BiomarcadoresRESUMEN
OBJECTIVE: To validate kappa free light chain (KFLC) and lambda free light chain (LFLC) indices as a diagnostic biomarker in multiple sclerosis (MS). METHODS: We performed a multicenter study including 745 patients from 18 centers (219 controls and 526 clinically isolated syndrome (CIS)/MS patients) with a known oligoclonal IgG band (OCB) status. KFLC and LFLC were measured in paired cerebrospinal fluid (CSF) and serum samples. Gaussian mixture modeling was used to define a cut-off for KFLC and LFLC indexes. RESULTS: The cut-off for the KFLC index was 6.6 (95% confidence interval (CI) = 5.2-138.1). The cut-off for the LFLC index was 6.9 (95% CI = 4.5-22.2). For CIS/MS patients, sensitivity of the KFLC index (0.88; 95% CI = 0.85-0.90) was higher than OCB (0.82; 95%CI = 0.79-0.85; p < 0.001), but specificity (0.83; 95% CI = 0.78-0.88) was lower (OCB = 0.92; 95% CI = 0.89-0.96; p < 0.001). Both sensitivity and specificity for the LFLC index were lower than OCB. CONCLUSION: Compared with OCB, the KFLC index is more sensitive but less specific for diagnosing CIS/MS. Lacking an elevated KFLC index is more powerful for excluding MS compared with OCB but the latter is more important for ruling in a diagnosis of CIS/MS.
Asunto(s)
Cadenas kappa de Inmunoglobulina/metabolismo , Cadenas lambda de Inmunoglobulina/metabolismo , Esclerosis Múltiple/diagnóstico , Bandas Oligoclonales , Adulto , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Femenino , Humanos , Cadenas kappa de Inmunoglobulina/sangre , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas lambda de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/líquido cefalorraquídeo , Masculino , Persona de Mediana Edad , Bandas Oligoclonales/sangre , Bandas Oligoclonales/líquido cefalorraquídeo , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
BACKGROUND AND PURPOSE: Cerebrospinal fluid (CSF) kappa free light chains (FLCs) may be a more sensitive marker of intrathecal immunoglobulin (Ig)G synthesis compared with oligoclonal bands (OCBs). Our aim was to retrospectively determine the additional value of the kappa and lambda index (CSF FLC/serum FLC)/(CSF albumin/serum albumin) in predicting a multiple sclerosis (MS) diagnosis in a group of OCB-negative patients with suspected MS. METHODS: The CSF and serum kappa and lambda FLCs were tested using the Freelite kit (serum) and Freelite Mx (CSF) assay (The Binding Site Group, Bimingham, UK) in 391 OCB-negative patients with suspected/possible MS and in 54 OCB-positive patients with MS. RESULTS: The CSF kappa FLC levels were below the detection limit (0.27 mg/L) in 61% of patients. Using quantitative data, we found the best kappa index cut-off value for the prediction of MS to be 5.8. A kappa index ≥5.8 was present in 25% of OCB-negative MS (23/92) and in 98% of OCB-positive patients with MS. Using a qualitative approach and a kappa index cut-off of 5.9, based on literature data, we likewise found that 24% of OCB-negative patients with MS had a kappa index ≥5.9, compared with 5.4% of OCB-negative patients without MS (P < 0.001). No reliable data could be obtained for the lambda index; lambda FLCs were below the detection limit (0.68 mg/L) in 90% of CSF samples. CONCLUSIONS: The kappa index could contribute to the identification of OCB-negative patients with a high probability of an MS diagnosis. Using more sensitive techniques might even improve the diagnostic performance of the kappa index and better define the role of the lambda index.
Asunto(s)
Inmunoglobulina G/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas lambda de Inmunoglobulina/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico , Bandas Oligoclonales/líquido cefalorraquídeo , Adulto , Biomarcadores/líquido cefalorraquídeo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/líquido cefalorraquídeo , Estudios RetrospectivosAsunto(s)
Enfermedades Desmielinizantes , Cadenas kappa de Inmunoglobulina , Humanos , Enfermedades Desmielinizantes/líquido cefalorraquídeo , Enfermedades Desmielinizantes/patología , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/sangre , Femenino , Masculino , Persona de Mediana Edad , Adulto , AncianoRESUMEN
BACKGROUND AND PURPOSE: The gold standard for detection of intrathecal immunoglobulin synthesis is the measurement of oligoclonal bands (OCB). In the diagnosis of multiple sclerosis, the kappa free light chains (KFLC) index has a similar sensitivity and specificity as OCB. This study investigated whether determination of the KFLC index could be used to predict the presence of OCB. METHODS: The KFLC index was determined prospectively from 295 paired serum and cerebrospinal fluid samples. KFLC were determined by nephelometry using the N Latex FLC kappa kit (Siemens Healthcare Diagnostics Products GmbH) on the BN Prospec analyzer (Siemens Healthcare Diagnostics Products GmbH) (cohort I). A cut-off value was determined using receiver operating characteristic analysis in relation to OCB positivity. These results were validated prospectively in 96 samples (cohort II) as well as retrospectively in samples of 46 patients known to be OCB positive (cohort III). We also compared the agreement of two commercially available nephelometric KFLC assays. RESULTS: In cohort I, a KFLC index of 3.61 yielded 100% sensitivity and 88% specificity. Prospective validation of this cut-off value in cohort II showed 92% sensitivity and 96% specificity. In cohort III, a sensitivity of 93% was achieved. Comparison of Siemens and Binding Site (Birmingham, UK) assays revealed good agreement (r2 = 0.86). CONCLUSIONS: The KFLC index with a cut-off value of 3.61 had high diagnostic accuracy to predict immunoglobulin G synthesis via OCB analysis. Determination of the KFLC index provided a quantitative parameter that could be used as an initial diagnostic step in inflammatory central nervous system disorders before measuring OCB.
Asunto(s)
Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Factores Inmunológicos/líquido cefalorraquídeo , Esclerosis Múltiple/líquido cefalorraquídeo , Bandas Oligoclonales/líquido cefalorraquídeo , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Inmunoglobulina G/biosíntesis , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/inmunología , Nefelometría y Turbidimetría , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
BACKGROUND: Free light chains (FLC) have been proposed as diagnostic biomarker in patients with inflammatory central nervous system diseases. The objective of this study was to investigate the diagnostic utility of intrathecal κ- and λ-FLC synthesis in patients with neuroborreliosis. METHODS: κ- and λ-FLC were measured by nephelometry under blinded conditions in cerebrospinal fluid (CSF) and serum sample pairs of 34 patients with neuroborreliosis and compared to a cohort of 420 control patients. κ-FLC index was calculated as [CSF κ-FLC/serum κ-FLC]/[CSF albumin/serum albumin], and λ-FLC index in analogy. RESULTS: κ-FLC and λ-FLC index were significantly elevated in patients with neuroborreliosis compared to the control group. At a specificity level of 95%, κ-FLC and λ-FLC index showed a diagnostic sensitivity of 88.2% and 100%. In comparison, IgM and IgG synthesis according to Reiber formula, IgG index >0.7 and OCB status reached a sensitivity of 83.9%, 44.1%, 58.8% and 64.7%. CONCLUSION: These findings support the diagnostic value of intrathecal FLC synthesis in neuroborreliosis patients and demonstrate a valid, easy and rater-independent alternative for the detection of an intrathecal immunoglobulin production.
Asunto(s)
Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas lambda de Inmunoglobulina/líquido cefalorraquídeo , Neuroborreliosis de Lyme/diagnóstico , Adolescente , Adulto , Anciano , Biomarcadores/líquido cefalorraquídeo , Niño , Femenino , Humanos , Neuroborreliosis de Lyme/líquido cefalorraquídeo , Masculino , Persona de Mediana Edad , Nefelometría y Turbidimetría , Adulto JovenRESUMEN
BACKGROUND: The determination of κ free light chains (KFLC) in cerebrospinal fluid (CSF) by nephelometry is a feasible alternative to immunoglobulin G oligoclonal bands (OCB) in the evaluation of intrathecal synthesis of immunoglobulin in multiple sclerosis (MS) and other demyelinating diseases. The aim of this study was to assess the diagnostic value of KFLC and its inclusion in a procedure algorithm along with OCB interpretation. METHODS: A cross-sectional study, which included 123 patients with a CSF OCB request, was carried out. Isoelectric focusing followed by immunofixation was used to detect OCB, and nephelometry was used to analyze KFLC. The KFLC index was calculated using CSF/serum quotient of KFLC and albumin. The KFLC index was compared with MS diagnosis to find the optimal cutoff. It was obtained from the receiver operating characteristic (ROC) curves and the Youden method. RESULTS: The CSF KFLC median was 1.66 mg/L in the MS group, whereas in other central nervous system diseases, KFLC showed generally no or only moderate increase in CSF (median 0.10 mg/L). KFLC index showed a significant difference between groups. ROC analysis for CSF KFLC concentration, and KFLC indexes were 91.88% and 93.94%, respectively. The best cutoff for the KFLC index was 2.91 for MS diagnosis (sensitivity: 83.78%; specificity: 85.88%). The proposed algorithm showed high sensitivity (89.19%) and specificity (84.71%). CONCLUSIONS: KFLC determination is rapid and automatized, but it has no higher sensitivity and specificity than OCB in MS diagnosis. Nevertheless, when used in screening, it could reduce the number of manual OCB tests.
Asunto(s)
Algoritmos , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Esclerosis Múltiple/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Estudios Transversales , Humanos , Cadenas kappa de Inmunoglobulina/sangre , Pruebas Inmunológicas , Focalización Isoeléctrica , Esclerosis Múltiple/sangre , Nefelometría y Turbidimetría , Sensibilidad y EspecificidadRESUMEN
BACKGROUND: Identifying new biomarkers is needed to overcome the diagnostic difficulties of pediatric multiple sclerosis (MS). Recently, we developed a new technique including CSF analysis of free light chain (FLC) monomers and dimers, which can improve diagnosis of adult MS. The present study has been designed to evaluate the utility of our technique for MS diagnosis in children. METHODS: Patients with MS (n=21) and non-MS demyelinating or inflammatory neurological disorders (n=35) participated in the study. MS diagnosis was based on clinical and magnetic resonance imaging (MRI) findings. Western blot analysis was applied to examine FLC in the patients' CSF and serum. FLC indices for FLC monomer and dimer levels and κ/λ ratios were estimated. The samples were also analyzed by oligoclonality test. RESULTS: The study revealed abnormally elevated levels of κ-FLC monomers and dimers in the CSF of 10 MS patients ("κ-type MS"). Increased amounts of λ dimers were found in six MS cases ("λ-type MS"), while high levels of both κ and λ FLC ("mixed type MS") were documented in three MS cases. MRI and clinical assessment showed a more aggressive disease form for the "mixed" and "λ-type" cases. Our method demonstrated higher sensitivity (90.5%) and specificity (91.4%) for discrimination between MS and non-MS patients, as compared to oligoclonality test (81% and 65.7%, respectively). CONCLUSIONS: The proposed method may significantly contribute to diagnosis and prognosis of pediatric MS.
Asunto(s)
Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico , Adolescente , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Encéfalo/patología , Niño , Preescolar , Femenino , Humanos , Cadenas kappa de Inmunoglobulina/sangre , Masculino , Bandas Oligoclonales/sangre , Bandas Oligoclonales/líquido cefalorraquídeoRESUMEN
BACKGROUND: Cerebrospinal fluid (CSF) used in immunoglobulin gamma (IgG) index testing and oligoclonal bands (OCBs) are common laboratory tests used in the diagnosis of multiple sclerosis. The measurement of CSF free light chains (FLC) could pose as an alternative to the labor-intensive isoelectric-focusing (IEF) gels used for OCBs. METHODS: A total of 325 residual paired CSF and serum specimens were obtained after physician-ordered OCB IEF testing. CSF kappa (cKFLC) and lambda FLC (cLFLC), albumin and total IgG were measured. Calculations were performed based on combinations of analytes: CSF sum of kappa and lambda ([cKFLC+cLFLC]), kappa-index (K-index) ([cKFLC/sKFLC]/[CSF albumin/serum albumin]), kappa intrathecal fraction (KFLCIF) {([cKFLC/sKFLC]-[0.9358×CSF albumin/serum albumin]^[0.6687×sKFLC]/cKFLC)} and IgG-index ([CSF IgG/CSF albumin]/[serum IgG/serum albumin]). RESULTS: Patients were categorized as: demyelination (n=67), autoimmunity (n=53), non-inflammatory (n=50), inflammation (n=38), degeneration (n=28), peripheral neuropathy (n=24), infection (n=13), cancer (n=11), neuromyelitis optica (n=10) and others (n=31). cKFLC measurement used alone at a cutoff of 0.0611 mg/dL showed >90% agreement to OCBs, similar or better performance than all other calculations, reducing the number of analytes and variables. When cases of demyelinating disease were reviewed, cKFLC measurements showed 86% clinical sensitivity/77% specificity. CONCLUSIONS: cKFLC alone demonstrates comparable performance to OCBs along with increased sensitivity for demyelinating diseases. Replacing OCB with cKFLC would alleviate the need for serum and CSF IgG and albumin and calculated conversions. cKFLC can overcome challenges associated with performance, interpretation, and cost of traditional OCBs, reducing costs and maintaining sensitivity and specificity supporting MS diagnosis.
Asunto(s)
Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas lambda de Inmunoglobulina/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico , Bandas Oligoclonales/líquido cefalorraquídeo , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Niño , Preescolar , Estudios de Cohortes , Femenino , Humanos , Cadenas kappa de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/sangre , Lactante , Masculino , Persona de Mediana Edad , Nefelometría y Turbidimetría , Sensibilidad y Especificidad , Adulto JovenRESUMEN
OBJECTIVES: The detection of cerebrospinal fluid (CSF)-specific IgG oligoclonal bands (OCB) by isoelectric focusing (IEF) is widely used to help diagnose inflammatory neurological disorders (IND), including multiple sclerosis. However, the quantification of free light chains (FLC) is increasingly evaluated as a surrogate method to determine the presence of an intrathecal inflammatory process. The objective of this study was to evaluate the diagnostic performance of kappa (κ) FLC measurement in comparison with OCB detection by IEF. MATERIAL AND METHODS: We measured serum and CSF κFLCs by turbidimetry using the SPAplus automated analyser and calculated the κ index in 142 samples from OCB-positive and negative MS, as well as from patients with inflammatory and non-inflammatory neurological disorders (IND and NIND). RESULTS: The κFLC index was significantly increased in OCB-positive MS and IND patients versus OCB-negative patients. Its performance was relatively comparable to that of IEF for MS diagnosis. When using a κFLC index cutoff value of 6.29, sensitivity increased from 61.2% to 75.7% in comparison with IEF for diagnosing IND (P = .0051), with a slightly lower non-statistically significant specificity (82.1% vs 100%). When considering both OCB status positivity or a κFLC index superior to 6.29 to diagnose IND status, sensitivity raised to 80.6% (P < .05) with an equal specificity. CONCLUSION: Our results demonstrate that the κFLC index does not discriminate MS from other IND patients, but is a reliable technique to detect intrathecal inflammation. However, κFLC quantification should probably be considered as a complementary method, rather than a substitute, to OCB detection.
Asunto(s)
Cadenas kappa de Inmunoglobulina/sangre , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Enfermedades del Sistema Nervioso/sangre , Enfermedades del Sistema Nervioso/líquido cefalorraquídeo , Adulto , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Femenino , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina G/líquido cefalorraquídeo , Cadenas Ligeras de Inmunoglobulina/sangre , Cadenas Ligeras de Inmunoglobulina/líquido cefalorraquídeo , Inflamación/sangre , Inflamación/líquido cefalorraquídeo , Inflamación/diagnóstico , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/sangre , Esclerosis Múltiple/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico , Nefelometría y Turbidimetría/métodos , Enfermedades del Sistema Nervioso/diagnóstico , Bandas Oligoclonales/sangre , Bandas Oligoclonales/líquido cefalorraquídeo , Estudios RetrospectivosRESUMEN
The latest revision of the McDonald criteria of 2017 considers the evidence of an intrathecal immunoglobulin (IgG) synthesis as a diagnostic criterion for dissemination in time in multiple sclerosis. While the detection of oligoclonal bands is considered as the gold standard, determination of kappa free light chains might be a promising tool as a less technically demanding and cost saving method. However, data on the direct comparison between kappa free light chains and oligoclonal bands are limited and no study to date has used the highly sensitive method of polyacrylamide gels with consecutive silver staining for the demonstration of oligoclonal bands. Furthermore, the impact of the revised McDonald criteria of 2017 on the role of kappa free light chains as a biomarker has not been investigated. Nephelometry was used to determine kappa free light chains in cerebrospinal fluid (CSF) and serum from 149 patients with their first demyelinating event between 2010 and 2015. Clinical data, kappa free light chains, and oligoclonal band status were compared at the time of initial diagnosis and after follow-up to identify converters from clinically isolated syndrome to multiple sclerosis. An elevated kappa free light chain index (>5.9) was found in 79/83 patients (95%) with multiple sclerosis diagnosed at baseline, slightly less frequent than oligoclonal bands (98.8%). 18/25 (72%) patients who converted from clinically isolated syndrome to multiple sclerosis showed an elevated kappa free light chain index compared to 20/25 (80%) patients with positive oligoclonal bands. In patients with stable clinically isolated syndrome 7/41 (17%) displayed an elevated kappa free light chain index against 11/41 (27%) oligoclonal band positive patients. Only two patients with stable clinically isolated syndrome showed an elevated kappa free light chain index but were oligoclonal bands negative. In conclusion, determination of the kappa free light chain index is a promising diagnostic approach to assess intrathecal immunoglobulin synthesis in multiple sclerosis. Nevertheless, oligoclonal bands are highly prevalent in multiple sclerosis and can detect an intrathecal synthesis of IgG even when the kappa free light chain index is below the threshold. We consider sequential use of both methods as reasonable.
Asunto(s)
Esclerosis Múltiple/diagnóstico , Bandas Oligoclonales/líquido cefalorraquídeo , Resinas Acrílicas , Adolescente , Adulto , Anciano , Femenino , Humanos , Cadenas Ligeras de Inmunoglobulina/sangre , Cadenas Ligeras de Inmunoglobulina/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/sangre , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/sangre , Esclerosis Múltiple/líquido cefalorraquídeo , Nefelometría y Turbidimetría , Bandas Oligoclonales/sangre , Estudios Retrospectivos , Adulto JovenRESUMEN
BACKGROUND: Cerebrospinal fluid (CSF) immunoglobulin free light chains (FLC) have been suggested as quantitative alternative to oligoclonal bands (OCB) in the diagnosis of multiple sclerosis (MS). However, little is known on their role in predicting clinical and paraclinical disease progression, particularly in early stages. OBJECTIVE: To assess the prognostic value of FLC in OCB-positive patients with clinically isolated syndrome (CIS) suggestive of MS and early MS. METHODS: We determined FLC kappa (KFLC) and lambda (LFLC) in CSF and serum by nephelometry in 61 patients (CIS ( n = 48), relapsing-remitting multiple sclerosis ( n = 13)) and 60 non-inflammatory neurological controls. Median clinical follow-up time in CIS was 4.8 years (interquartile range (IQR), 1.5-6.5 years). Patients underwent 3T magnetic resonance imaging (MRI) at baseline and follow-up (median time interval, 2.2 years; IQR, 1.0-3.7 years) to determine T2 lesion load (T2LL) and percent brain volume change (PBVC). RESULTS: CSF FLC were significantly increased in CIS/MS compared to controls (all p < 0.001). A lower KFLC/LFLC CSF ratio was associated with CIS-clinically definite multiple sclerosis (CDMS) conversion (hazard ratio (HR) = 2.89; 95% confidence interval (CI) = 1.17-7.14; p < 0.05). No correlations were found for FLC variables with T2LL or PBVC. CONCLUSION: Our study confirms increased intrathecal synthesis of FLC in CIS/MS which supports their diagnostic contribution. The KFLC/LFLC CSF ratio appears to have a prognostic value in CIS beyond OCB.
Asunto(s)
Biomarcadores/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas lambda de Inmunoglobulina/líquido cefalorraquídeo , Esclerosis Múltiple/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico por imagen , Adulto , Biomarcadores/sangre , Femenino , Estudios de Seguimiento , Humanos , Cadenas kappa de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/sangre , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/sangre , Esclerosis Múltiple Recurrente-Remitente/sangre , Esclerosis Múltiple Recurrente-Remitente/líquido cefalorraquídeo , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , PronósticoRESUMEN
IgG kappa and IgG lambda concentrations were quantified in 96 paired CSF and sera using Hevylite™ antibodies in an in-house developed sandwich ELISA method. In 56 of these samples, the results were compared with a qualitative isoelectric focusing/affinity-mediated immunoblotting assay for oligoclonal IgG kappa and IgG lambda. Normal IgG kappa/lambda ratio in the CSF was the same as in serum. In 19/33 patients with intrathecal oligoclonal IgG synthesis, skewed IgG kappa/lambda ratio was observed (increased in 16 and decreased in 3 cases). The analysis of light chain composition of intrathecally synthesised immunoglobulins could contribute to our understanding of intrathecal humoral immune response, although its diagnostic utility is limited.
Asunto(s)
Ensayo de Inmunoadsorción Enzimática/métodos , Inmunoglobulina G/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas lambda de Inmunoglobulina/líquido cefalorraquídeo , Humanos , Inmunoglobulina G/inmunología , Cadenas kappa de Inmunoglobulina/inmunología , Cadenas lambda de Inmunoglobulina/inmunologíaRESUMEN
BACKGROUND: Kappa free light chains (KFLCs) have been proposed as a diagnostic biomarker in patients with clinically isolated syndrome (CIS) and multiple sclerosis (MS). OBJECTIVE: The objective of this paper is to validate the diagnostic accuracy of intrathecal KFLC synthesis in a multicenter study. METHODS: KFLCs were measured by nephelometry under blinded conditions in cerebrospinal fluid (CSF) and serum sample pairs of patients with CIS (n = 60), MS (n = 60) and other neurological diseases (n = 60) from four different MS centers. The upper normal limit for intrathecal KFLC concentrations depending on blood-CSF barrier function was previously calculated in a cohort of 420 control patients. RESULTS: Diagnostic sensitivity of intrathecal KFLC synthesis, IgG synthesis according to Reiber, IgG index and oligoclonal bands (OCBs) was 95%, 72%, 73% and 93% in patients with MS and 82%, 47%, 43% and 72% in patients with CIS. Specificity of intrathecal KFLC synthesis was 95% and 98% for all other measures. CONCLUSION: These findings further support the diagnostic value of intrathecal KFLC synthesis in CIS and MS patients and demonstrate a valid, easier and rater-independent alternative to OCB detection.
Asunto(s)
Enfermedades Desmielinizantes/diagnóstico , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico , Adulto , Anciano , Austria , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Estudios Transversales , Enfermedades Desmielinizantes/sangre , Enfermedades Desmielinizantes/líquido cefalorraquídeo , Enfermedades Desmielinizantes/inmunología , Femenino , Alemania , Humanos , Cadenas kappa de Inmunoglobulina/sangre , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/sangre , Esclerosis Múltiple/líquido cefalorraquídeo , Esclerosis Múltiple/inmunología , Nefelometría y Turbidimetría , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto JovenRESUMEN
Recently, serum free light chain (FLC) assays incorporating anti-kappa (κ) and anti-lambda (λ) FLC monoclonal antibodies have become available: N Latex FLC assay (Siemens) and Seralite® (Abingdon Health). The purpose of this review is to provide an overview of these two new monoclonal antibody-based methods. In doing so, the review will outline the performance characteristics of each method, including a summary of: assay principles, antibody specificity, analytical performance and assay performance in disease. Additionally, the review will describe the potential user benefits of adopting these new generation FLC assays, which are designed to overcome the established limitations of existing polyclonal antibody based FLC assays.
Asunto(s)
Anticuerpos Monoclonales/inmunología , Inmunoensayo/métodos , Cadenas Ligeras de Inmunoglobulina/análisis , Amiloidosis/diagnóstico , Amiloidosis/inmunología , Animales , Humanos , Cadenas Ligeras de Inmunoglobulina/inmunología , Cadenas kappa de Inmunoglobulina/sangre , Cadenas kappa de Inmunoglobulina/líquido cefalorraquídeo , Cadenas kappa de Inmunoglobulina/orina , Cadenas lambda de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/líquido cefalorraquídeo , Cadenas lambda de Inmunoglobulina/orina , Espectrometría de Masas/métodos , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/inmunología , Paraproteinemias/diagnósticoRESUMEN
OBJECTIVE: Multiple sclerosis (MS) is a chronic, inflammatory, demyelinating disease of the central nervous system with varying progression rates among individuals. The ability to predict disease progression is crucial for treatment decisions with disease-modifying therapies (DMTs). A few cerebrospinal fluid (CSF) biomarkers have been investigated in relation to disease progression, but few have been effectively translated into clinical practice. The aim of this study was to evaluate the diagnostic and prognostic value of known CSF markers, to compare their sensitivity and specificity, and to develop a prognostic model using a combination of markers to predict disease progression. METHODS: This retrospective cohort study included 82 patients with a first episode of inflammatory demyelinating symptoms suggestive of MS between January 2018 and January 2021. Patients underwent diagnostic lumbar puncture and other investigations according to the multiple sclerosis (MS) protocol. They were divided into three groups according to MRI findings, relapse rate and EDSS score. CSF marker concentrations were determined by laser nephelometry and electrochemiluminescence immunoassay. RESULTS: The results showed that the number of oligoclonal bands could discriminate the progression-free group from the other groups, but had a lower discriminatory power compared to CSF marker concentrations. Among CSF markers, FLC kappa showed the best discriminatory performance. By combining FLC kappa with gender and lesion localization information, a simple predictor of progression-free group membership was proposed. This predictor showed good sensitivity (91 %) and specificity (65 %). CONCLUSION: In conclusion, CSF FLC kappa concentration, together with gender and lesion localization, may be a valuable predictor of disease progression in MS patients. This study highlights the potential of using CSF biomarkers for prognostic purposes and offers a simple approach to predicting disease progression.