Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
Más filtros

Intervalo de año de publicación
1.
BMC Vet Res ; 20(1): 188, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730373

RESUMEN

Femoral fractures are often considered lethal for adult horses because femur osteosynthesis is still a surgical challenge. For equine femur osteosynthesis, primary stability is essential, but the detailed physiological forces occurring in the hindlimb are largely unknown. The objective of this study was to create a numerical testing environment to evaluate equine femur osteosynthesis based on physiological conditions. The study was designed as a finite element analysis (FEA) of the femur using a musculoskeletal model of the loading situation in stance. Relevant forces were determined in the musculoskeletal model via optimization. The treatment of four different fracture types with an intramedullary nail was investigated in FEA with loading conditions derived from the model. The analyzed diaphyseal fracture types were a transverse (TR) fracture, two oblique fractures in different orientations (OB-ML: medial-lateral and OB-AP: anterior-posterior) and a "gap" fracture (GAP) without contact between the fragments. For the native femur, the most relevant areas of increased stress were located distally to the femoral head and proximally to the caudal side of the condyles. For all fracture types, the highest stresses in the implant material were present in the fracture-adjacent screws. Maximum compressive (-348 MPa) and tensile stress (197 MPa) were found for the GAP fracture, but material strength was not exceeded. The mathematical model was able to predict a load distribution in the femur of the standing horse and was used to assess the performance of internal fixation devices via FEA. The analyzed intramedullary nail and screws showed sufficient stability for all fracture types.


Asunto(s)
Fracturas del Fémur , Fijación Interna de Fracturas , Miembro Posterior , Animales , Caballos/fisiología , Fenómenos Biomecánicos , Fracturas del Fémur/veterinaria , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/veterinaria , Fijación Interna de Fracturas/métodos , Miembro Posterior/cirugía , Análisis de Elementos Finitos , Fémur/cirugía , Modelos Biológicos , Soporte de Peso , Fijación Intramedular de Fracturas/veterinaria , Fijación Intramedular de Fracturas/instrumentación
2.
BMC Musculoskelet Disord ; 25(1): 456, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38851687

RESUMEN

BACKGROUND: Osteosynthesis using antegrade intramedullary nailing for humeral shaft fractures yields satisfactory bone union rates; however, it may adversely affect postoperative shoulder function. To date, factors affecting mid- or long-term shoulder functional outcomes following intramedullary nail fixation have not been clarified. In this study, we aimed to identify the risk factors for poor mid-term functional outcomes over 5 years postoperatively following antegrade intramedullary nail osteosynthesis for humeral shaft fractures. METHODS: We retrospectively identified 33 patients who underwent surgery using an antegrade intramedullary nail for acute traumatic humeral shaft fractures and were followed up for at least 5 years postoperatively. We divided the patients into clinical failure and no clinical failure groups using an age- and sex-adjusted Constant score of 55 at the final follow-up as the cutoff value. We compared preoperative, perioperative, and postoperative factors between the two groups. RESULTS: Five of the 33 patients had poor shoulder functional outcomes (adjusted Constant score < 55) at a mean follow-up of 7.5 years postoperatively. Proximal protrusion of the nail at the time of bone union (P = 0.004) and older age (P = 0.009) were significantly associated with clinical failure in the univariate analyses. Multivariate analysis showed that proximal protrusion of the nail (P = 0.031) was a risk factor for poor outcomes. CONCLUSIONS: The findings of this study provide new information on predictive factors affecting mid-term outcomes following osteosynthesis using antegrade nails. Our results demonstrated that proximal protrusion of the nail was significantly associated with poor mid-term functional shoulder outcomes. Therefore, particularly in older adults, it is essential to place the proximal end of the intramedullary nail below the level of the articular cartilage.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Fracturas del Húmero , Humanos , Estudios Retrospectivos , Femenino , Masculino , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/instrumentación , Fracturas del Húmero/cirugía , Persona de Mediana Edad , Adulto , Estudios de Seguimiento , Factores de Riesgo , Anciano , Resultado del Tratamiento , Rango del Movimiento Articular , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Curación de Fractura , Recuperación de la Función , Adulto Joven
3.
BMC Musculoskelet Disord ; 25(1): 531, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38987691

RESUMEN

BACKGROUND: The treatment of the displaced proximal humerus fractures (PHF) still facing a lot of unsolved problems. The aim of this study was to evaluate the clinical effect of MultiLoc nails for the treatment of PHF and present outcomes of patients with different Neer's classification and reduction quality. METHODS: Adult patients with PHFs were recruited and treated with MultiLoc nail. Intraoperative data, radiographic and functional outcomes, as well as occurrence of postoperative complications were assessed. RESULTS: 48 patients met inclusion and exclusion criteria and were included in this study. The DASH Score were 32.2 ± 3.1 points at 12 months, and 37.3 ± 2.5 points at the final follow-up. The mean ASES score at 12 months and final follow-up were 74.4 ± 6.2 and 78.8 ± 5.1, respectively. The mean CM Score in all 48 patients reached 68 ± 6.4 points at the final follow-up, relative side related CM Score 75.2 ± 7.7% of contralateral extremity. The incidence rate of complications was 20.8%. Patients with fracture mal-union, adhesive capsulitis were observed but no secondary surgeries were performed. There was no significantly difference of DASH Score 12 months after surgery and at the last follow-up among patients with different Neer's classification or reduction quality. However, functional outcomes such as ASES score and CM score were significantly influenced by severity of fracture and the quality of fracture reduction. CONCLUSIONS: Our study demonstrated that MultiLoc nails is well suited for proximal humeral fractures, with satisfactory health status recovery, good radiographic results, positive clinical outcomes and low rates of complications. The treatment for four part PHF still faces great challenges. Accurate fracture reduction was an important factor for good functional result.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Complicaciones Posoperatorias , Fracturas del Hombro , Humanos , Fracturas del Hombro/cirugía , Fracturas del Hombro/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Adulto , Estado de Salud , Estudios de Seguimiento , Radiografía , Estudios Retrospectivos
4.
BMC Musculoskelet Disord ; 25(1): 389, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38762453

RESUMEN

BACKGROUND: Several methods have been used for the treatment of pediatric distal femoral fractures, such as elastic stable intramedullary nail (ESIN), external fixator (EF) and plate osteosynthesis, but there has been no consensus about the optimal method. The purpose of this study was to compare the clinical outcome between EF and ESIN techniques used in metaphyseal-diaphyseal junction (MDJ) fractures of the pediatric distal femur. METHODS: We retrospectively analyzed operatively treated MDJ fractures of pediatric distal femur between January 2015 and January 2022. Patient charts were reviewed for demographics, injury and data of radiography. All of the patients were divided into EF and ESIN groups according to the operation techniques. Malalignment was defined as more than 5 degrees of angular deformity in either plane. Clinical outcomes were measured by Flynn scoring system. RESULTS: Thirty-eight patients were included in this study, among which, 23 were treated with EF, and 15 with ESIN. The mean follow-up time was 18 months (12-24 months). At the final follow-up, all of the fractures were healed. Although there were no statistical differences between the two groups in demographic data, length of stay, estimated blood loss (EBL), rate of open reduction, time to fracture healing and Flynn score, the EF was superior to ESIN in operative time, fluoroscopic exposure and time to partial weight-bearing. The EF group had a significantly higher rate of skin irritation, while the ESIN had a significantly higher rate of malalignment. CONCLUSION: EF and ESIN are both effective methods in the treatment of MDJ fractures of the pediatric distal femur. ESIN is associated with lower rates of skin irritation. However, EF technique has the advantages of shorter operative time, reduced fluoroscopic exposure, and shorter time to partial weight-bearing, as well as lower incidence of malalignment. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Clavos Ortopédicos , Fijadores Externos , Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Femenino , Masculino , Estudios Retrospectivos , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Niño , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Resultado del Tratamiento , Estudios de Casos y Controles , Curación de Fractura , Diáfisis/lesiones , Diáfisis/cirugía , Diáfisis/diagnóstico por imagen , Preescolar , Estudios de Seguimiento , Adolescente , Fémur/cirugía , Fémur/diagnóstico por imagen
5.
BMC Musculoskelet Disord ; 25(1): 405, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38783225

RESUMEN

Femoral head varus is an important complication in intertrochanteric fracture patients treated with proximal femoral nail anti-rotation (PFNA) fixation. Theoretically, extending the length of the intramedullary nail could optimize fixation stability by lengthening the force arm. However, whether extending the nail length can optimize patient prognosis is unclear. In this study, a review of imaging data from intertrochanteric fracture patients with PFNA fixation was performed, and the length of the intramedullary nail in the femoral trunk and the distance between the lesser trochanter and the distal locking screw were measured. The femoral neck varus status was judged at the 6-month follow-up. The correlation coefficients between nail length and femoral neck varus angle were computed, and linear regression analysis was used to determine whether a change in nail length was an independent risk factor for femoral neck varus. Moreover, the biomechanical effects of different nail lengths on PFNA fixation stability and local stress distribution have also been verified by numerical mechanical simulations. Clinical review revealed that changes in nail length were not significantly correlated with femoral head varus and were also not an independent risk factor for this complication. In addition, only slight biomechanical changes can be observed in the numerical simulation results. Therefore, commonly used intramedullary nails should be able to meet the needs of PFNA-fixed patients, and additional procedures for longer nail insertion may be unnecessary.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Fenómenos Biomecánicos/fisiología , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/efectos adversos , Femenino , Masculino , Anciano , Fracturas de Cadera/cirugía , Fracturas de Cadera/diagnóstico por imagen , Cabeza Femoral/cirugía , Cabeza Femoral/diagnóstico por imagen , Anciano de 80 o más Años , Factores de Riesgo , Persona de Mediana Edad , Simulación por Computador
6.
BMC Musculoskelet Disord ; 25(1): 552, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39014409

RESUMEN

BACKGROUND: To evaluate the effectiveness of a sequential internal fixation strategy and intramedullary nailing with plate augmentation (IMN/PA) for bone reconstruction in the management of infected femoral shaft defects using the Masquelet technique. METHODS: We performed a retrospective descriptive cohort study of 21 patients (mean age, 36.4 years) with infected bone defects of the femoral shaft treated by the Masquelet technique with a minimum follow-up of 18 months after second stage. After aggressive debridement, temporary stabilisation (T1) was achieved by an antibiotic-loaded bone cement spacer and internal fixation with a bone cement-coated locking plate. At second stage (T2), the spacer and the locking plate were removed following re-debridement, and IMN/PA was used as definitive fixation together with bone grafting. We evaluated the following clinical outcomes: infection recurrence, bone union time, complications, and the affected limb's knee joint function. RESULTS: The median and quartiles of bone defect length was 7 (4.75-9.5) cm. Four patients required iterative debridement for infection recurrence after T1. The median of interval between T1 and T2 was 10 (9-19) weeks. At a median follow-up of 22 (20-27.5) months, none of the patients experienced recurrence of infection. Bone union was achieved at 7 (6-8.5) months in all patients, with one patient experiencing delayed union at the distal end of bone defect due to screws loosening. At the last follow-up, the median of flexion ROM of the knee joint was 120 (105-120.0)°. CONCLUSIONS: For infected femoral shaft bone defects treated by the Masquelet technique, sequential internal fixation and IMN/PA for the reconstruction can provide excellent mechanical stability, which is beneficial for early functional exercise and bone union, and does not increase the rate of infection recurrence.


Asunto(s)
Clavos Ortopédicos , Placas Óseas , Desbridamiento , Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Masculino , Estudios Retrospectivos , Femenino , Adulto , Fracturas del Fémur/cirugía , Persona de Mediana Edad , Desbridamiento/métodos , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Adulto Joven , Resultado del Tratamiento , Trasplante Óseo/métodos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Estudios de Seguimiento , Cementos para Huesos/uso terapéutico , Antibacterianos/uso terapéutico , Antibacterianos/administración & dosificación , Fémur/cirugía , Adolescente
7.
BMC Musculoskelet Disord ; 25(1): 534, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38997683

RESUMEN

BACKGROUND: The rotational change after using a flexible intramedullary (IM) nail for femoral shaft fractures has been a concern for many surgeons. Recently, a statistical shape model (SSM) was developed for the three-dimensional reconstruction of the femur from two-dimensional plain radiographs. In this study, we measured postoperative femoral anteversion (FAV) in patients diagnosed with femoral shaft fractures who were treated with flexible IM nails and investigated age-related changes in FAV using the SSM. METHODS: This study used radiographic data collected from six regional tertiary centers specializing in pediatric trauma in South Korea. Patients diagnosed with femoral shaft fractures between September 2002 and June 2020 and patients aged < 18 years with at least two anteroposterior (AP) and lateral (LAT) femur plain radiographs obtained at least three months apart were included. A linear mixed model (LMM) was used for statistical analysis. RESULTS: Overall, 72 patients were included in the study. The average patient age was 7.6 years and the average follow-up duration was 6.8 years. The average FAV of immediate postoperative images was 27.5 ± 11.5°. Out of 72 patients, 52 patients (72.2%) showed immediate postoperative FAV greater than 20°. The average FAV in patients with initial FAV > 20° was 32.74°, and the LMM showed that FAV decreased by 2.5° (p = 0.0001) with each 1-year increase from the time of initial trauma. CONCLUSIONS: This study explored changes in FAV after femoral shaft fracture using a newly developed technology that allows 3D reconstruction from uncalibrated 2D images. There was a pattern of change on the rotation of the femur after initial fixation, with a 2.5° decrease of FAV per year.


Asunto(s)
Clavos Ortopédicos , Fracturas del Fémur , Fémur , Fijación Intramedular de Fracturas , Humanos , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/efectos adversos , Niño , Femenino , Masculino , Preescolar , Adolescente , Fémur/cirugía , Fémur/diagnóstico por imagen , Estudios Retrospectivos , República de Corea/epidemiología , Resultado del Tratamiento , Estudios de Seguimiento , Anteversión Ósea/diagnóstico por imagen , Anteversión Ósea/etiología , Imagenología Tridimensional
8.
Surg Innov ; 31(4): 373-380, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38654530

RESUMEN

BACKGROUND: Minimally invasive treatment has become the most popular and effective treatment for pelvic fractures. This study aimed to evaluate the safety and efficacy of a new technique, titanium elastic nailing (TEN), for the minimally invasive treatment of pelvic fractures. METHOD: Twenty-four patients with pelvic fractures were referred to us between January 2020 to January 2022, including sixteen males and 8 females. Pelvic fractures were temporarily fixed by pelvic fixation belt accompanied by traction from the lower limb bone. Anterior pelvic ring injuries (superior ramus of pubis) and ilium fractures were treated with closed reduction and intramedullary fixation with minimally invasive TEN. Intraoperative C-arm, including pelvic anteroposterior, pelvic outlet, inlet and ilium oblique views, and O-arm fluoroscopy (intraoperative CT) were employed to assess fractures reduction and determine the location of the elastic titanium nail within the bone channel. RESULTS: By adopting closed reduction and minimally invasive incision techniques, pelvic fractures could be safely fixed by placing an elastic titanium nail in the osseous medullary cavity channels of the pelvis. Postoperative investigation indicated that the wounds of all patients were healed in the first stage without any occurrence of complications, such as injuries to the nerves, blood vessels, and important tissue structures. Patients are essential quickly after the operation and could perform the functional exercise in the early stages of the recovery. CONCLUSION: TEN can be used for minimally invasive treatment of pelvic fractures. This novel technique has no obvious complications and is worthwhile in clinical practice.


Asunto(s)
Clavos Ortopédicos , Fracturas Óseas , Procedimientos Quirúrgicos Mínimamente Invasivos , Huesos Pélvicos , Titanio , Humanos , Femenino , Masculino , Huesos Pélvicos/lesiones , Huesos Pélvicos/cirugía , Fracturas Óseas/cirugía , Adulto , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Persona de Mediana Edad , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Adulto Joven , Resultado del Tratamiento
9.
Int Orthop ; 48(8): 2189-2200, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38772935

RESUMEN

PURPOS: To evaluate the clinical efficacy of the Medial Sustain Nail (MSN) for medial comminuted trochanteric fractures fixation in comparison to Proximal Femoral Nail Antirotation (PFNA) through a clinical study. METHODS: A non-inferiority randomized controlled trial was conducted at a single centre between July 2019 and July 2020. Fifty patients diagnosed comminuted trochanteric fractures were randomly assigned to either the MSN group (n = 25) or the PFNA group (n = 25). A total of forty-three patients were included in the final study analysis. The primary outcome measure was Short Form 36 health surgery physical component summary (SF-36 PCS) score. Secondary outcomes included the Oxford Hip Scores (OHS), weight bearing, complication relate to implant and so on. This study was not blined to surgeons, but to patients and data analysts. RESULTS: The MSN demonstrated significantly better functional outcomes as measured by SF-36 PCS and OHS at six months postoperative compared to PFNA (p < 0.05). Union of fractures in the MSN group reached 90.9% at three months after surgery, whereas the PFNA group achieved a union rate of 57.1% (p < 0.05). Furthermore, weight-bearing time of MSN group was earlier than PFNA group (p < 0.05). Additionally, complications related to implant usage were more prevalent in the PFNA group (33.3%) compared to the MSN group (4.5%) (p < 0.05). CONCLUSION: MSN exhibited superior quality of life outcomes compared to PFNA at six months postoperative. This indicates that MSN effectively reconstructs medial femoral support in patients with comminuted trochanteric fractures, which facilitates early weight-bearing and accelerates the recovery process. TRIAL REGISTRATION: Trial registration number: NCT01437176, Date of the trial registration:2011-9-1, Date of commencement of the study:2011-9, Date of enrolment/recruitment of the study subjects:2019-7.


Asunto(s)
Clavos Ortopédicos , Fracturas Conminutas , Fracturas de Cadera , Humanos , Femenino , Fracturas de Cadera/cirugía , Masculino , Anciano , Fracturas Conminutas/cirugía , Estudios Prospectivos , Anciano de 80 o más Años , Resultado del Tratamiento , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Persona de Mediana Edad
10.
Int Orthop ; 48(7): 1839-1848, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38580780

RESUMEN

PURPOSE: The optimal choice of distal locking modes remains a subject due to limited available data, and therefore, this study aims to investigate the relationship between distal locking mode and postoperative mechanical complications in an intertrochanteric fracture (ITF) population who underwent closed reduction and intramedullary fixation with a PFNA-II. METHODS: Patients aged 65 years or older who underwent surgery with PFNA-II fixation in a university teaching hospital between January 2020 and December 2021 were potentially eligible. Based on the distal locking mode, patients were classified into static, dynamic, and limited dynamic groups, among which the differences were tested using univariate analysis. Multivariate logistic regression was used to examine whether the distal locking mode was independently associated with the risk of postoperative one year mechanical complications, adjusting for covariates and potential confounders. Subgroup analyses were performed to evaluate the robustness of the findings. RESULT: Among 507 eligible patients, 33 (6.5%) developed postoperative mechanical complications. In the univariate analysis, sex (P = 0.007), fracture type (P = 0.020), LAT Parker ratio (P = 0.023), and lateral femoral (P = 0.003) wall showed that the differences were significant. Compared to the static group, the limited dynamic group and the dynamic group showed higher odds of postoperative mechanical complications (OR = 3.314, 95% CI: 1.215-9.041; and OR = 3.652, 95% CI: 1.451-9.191, respectively). These associations were robust across a series of analyses, including adjusting for confounders and subgroup analyses. CONCLUSION: Using a distal non-static locking mode significantly increases the risk of postoperative mechanical complications, and static locking could be a preferable option when treating an intertrochanteric fracture.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Complicaciones Posoperatorias , Humanos , Masculino , Femenino , Anciano , Fracturas de Cadera/cirugía , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Anciano de 80 o más Años , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Estudios de Cohortes
11.
Int Orthop ; 48(8): 2179-2187, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38761212

RESUMEN

PURPOSE: Femoral fractures are common in low and middle-income countries (LMIC), predominantly caused by high-energy trauma. The surgical implant generation network (SIGN®) program offers two different intramedullary nails in LMIC which are designed to be used without image intensifier free of charge for the patients: the SIGN standard nail (SSN®) and the SIGN Fin nail (SFN®). This study aimed to compare the results of the SSN® and the SFN® for the treatment of middle and distal shaft femoral fractures through a retrograde approach. MATERIAL AND METHODS: This was a retrospective, descriptive, and non-experimental study including all consecutive patients who underwent surgical management of middle or distal shaft femoral fracture between January 2017 and May 2022 in an NGO hospital located in Freetown, Sierra Leone. The duration of surgery, type of reduction, complications like screw loosening, implant migration, anterior knee pain and non-union rate at six months of follow up were evaluated. RESULTS: A total of 122 patients were included in the study. Group A: 60 patients were managed with SSN® and Group B: 62 patients with SFN®. The mean operative time was 104 min with SSN® and 78 with SFN® (p < 0.001). Open reduction of the fracture was necessary in ten (16.7%) patients with SSN® and 12 (19.4%) patients treated with SFN® (p = 0.69). Non-union was observed in one (1.7%) patient with SSN® and two (3.2%) patients with SFN® (p = 0.57). CONCLUSIONS: Both options seem equally effective in treating midshaft and distal femoral shaft fractures. The SFN® reduces the surgical time, due to this fact, in polytraumatized patients, patients with bilateral femur fracture or patients with ipsilateral tibia fracture, it can be considered as the best option to be used. There was no statistical difference in the complications presented by the two groups.


Asunto(s)
Clavos Ortopédicos , Países en Desarrollo , Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Fracturas del Fémur/cirugía , Estudios Retrospectivos , Femenino , Masculino , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Adulto , Persona de Mediana Edad , Adulto Joven , Anciano , Resultado del Tratamiento , Tempo Operativo , Adolescente
12.
Arch Orthop Trauma Surg ; 144(5): 2157-2163, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38613611

RESUMEN

INTRODUCTION: The standard surgical procedure for unstable ankle fractures is fixation of the lateral malleolus with a plate and screws. This method has a high risk of complications, especially among patients with fragile skin conditions. The aim of this study was to estimate the re-operation rates and identify complications in patients with an unstable ankle fracture, surgically treated with an intramedullary screw or rush pin. MATERIALS AND METHODS: We identified all patients who were surgically treated with either a 3.5-mm screw or rush pin at Aarhus University Hospital, Denmark, from 2012 to 2018. Major complications were re-operations within three months. We included 80 patients, of which 55 (69%) were treated with a 3.5-mm intramedullary screw and 25 (31%) with a rush pin. The majority of the study population was female (59) and the mean age was 75 (range 24 to 100) years. Of the 80 patients included, 41 patients had more than 2 comorbidities. RESULTS: Three patients underwent re-operation within three months due to either fracture displacement or hardware cutout. Radiographs obtained after six weeks showed that nine patients had loss of reduction. Additionally, four patients had superficial wound infections and six patients had delayed wound healing. CONCLUSIONS: Intramedullary fixation of distal fibula fractures with either a screw or rush pin has low re-operation rates. However, the high proportion of patients with radiological loss of reduction is concerning.


Asunto(s)
Fracturas de Tobillo , Clavos Ortopédicos , Tornillos Óseos , Fijación Intramedular de Fracturas , Reoperación , Humanos , Femenino , Fracturas de Tobillo/cirugía , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Anciano , Anciano de 80 o más Años , Reoperación/estadística & datos numéricos , Adulto Joven , Complicaciones Posoperatorias/epidemiología
13.
Arch Orthop Trauma Surg ; 144(6): 2603-2608, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38700673

RESUMEN

INTRODUCTION: The primary aim of this study was to evaluate the clinical and radiological outcomes after surgical treatment of proximal femoral fractures utilizing the Proximal Femoral Nail Antirotation (PFNA), with the main focus on complications and reoperations. The secondary aim was to compare the outcomes of patients with and without cement augmentation of the cephalomedullary nails. MATERIALS AND METHODS: All patients with an acute proximal femoral fracture consequently treated with a PFNA between January 2011 and Dezember  2018 were evaluated. Clinical and radiological data were assessed for intra- and postoperative complications, including treatment failure. In addition, intra- and postoperative radiographs were used to determine the position of the implant, and any migration, via Tip-Apex-Distance (TAD) and the caput-collum-diaphyseal angle (CCD). The accuracy of the fracture reduction was rated according to Baumgaertners criteria. RESULTS: Two hundred sixty-four consecutive patients (mean age 78.8 ± 12.0; 73.1% female) were included. The predominant OTA/AO fracture classification was 31A1 (153 cases, 58.0%). The average duration of surgery was 63.1 ± 28.0 min and showed no significant differences between PFNA and PFNA with augmentation. The implant positioning was rated as good in 222 cases (84.1%). Two hundred sixty-three patients (99.6%) showed evidence of healing within the time frame of three months postoperatively, one case of delayed union healed after secondary dynamization. During the observational period, 18 patients (6.8%) required a total of 23 additional surgeries. Overall, a lower reoperation rate was observed following the use of the augmentation option (2/86 patients (2.3%) vs. 16/178 patients (9.0%), p = 0.04). In particular, there were no cases of cut-out or cut-through among patients who underwent augmentation as part of osteosynthesis. CONCLUSIONS: Overall reoperation rate after surgical treatment of proximal femoral fractures utilizing the Proximal Femoral Nail Antirotation (PFNA) was 6.8%, with 23 additional surgeries performed in 18 patients. The usage of the PFNA with augmentation showed equally good implant positioning, excellent healing rates and fewer postoperative complications compared to the PFNA implant alone with a similar overall duration of surgery.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Humanos , Femenino , Masculino , Anciano , Estudios Retrospectivos , Anciano de 80 o más Años , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Reoperación/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Persona de Mediana Edad , Radiografía , Resultado del Tratamiento , Fracturas de Cadera/cirugía , Fracturas de Cadera/diagnóstico por imagen , Cementos para Huesos/uso terapéutico , Fracturas Femorales Proximales
14.
Arch Orthop Trauma Surg ; 144(5): 2109-2118, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38466373

RESUMEN

INTRODUCTION: Fractures of the distal femur with metaphyseal comminution and complete intra-articular involvement (AO/OTA classifications 33C2 and 33C3) present challenges for reduction and fixation. However, an optimal fixation method remains unknown. This study aimed to compare the clinical and radiographic outcomes of locking extramedullary plating (LEP) and retrograde intramedullary nailing (RIN) for complete distal femoral intra-articular fractures with metaphyseal comminution. MATERIALS AND METHODS: Between January 2016 and May 2022, 80 patients (45 men and 35 women; average age, 56.7 years) diagnosed with AO/OTA 33C2 and 33C3 were treated with either LEP or RIN and followed up for at least one year. Post-operative evaluations included radiographic assessments of bone union rate, timing, and alignment. Clinically, the knee joint range of motion (ROM), lower extremity functional scale (LEFS), and Kellgren and Lawrence (KL) grade were analyzed. The complications were also compared. RESULTS: 36 underwent LEP and 44 underwent RIN. Bone union was observed in 69.4% and 63.6% of the patients in the LEP and RIN groups, respectively (p = 0.64). The average union time was 6.9 months for the LEP group and 6.6 months for the RIN group (p = 0.51). A tendency toward varus deformity was observed in the RIN group, although the difference was not statistically significant. No significant differences were observed in knee ROM, LEFS, or KL grade. Complications included non-union (33.8%; RIN, 11; LEP, 16), varus deformity (5%; RIN, 4; LEP, 0), infection (1.3%; RIN, 0; LEP, 1), heterotrophic ossification (1.3%; RIN, 0; LEP, 1), and wound dehiscence (2.5%; RIN, 2; LEP, 0). CONCLUSIONS: The surgical fixation methods, RIN and LEP, for complete distal femoral intra-articular fractures with metaphyseal comminution showed similar clinical and radiological outcomes. However, regardless of the type of fixation device used, there was a reduced rate of bone union owing to high energy and a less favorable prognosis.


Asunto(s)
Placas Óseas , Fracturas del Fémur , Fijación Intramedular de Fracturas , Fracturas Conminutas , Humanos , Persona de Mediana Edad , Femenino , Masculino , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Anciano , Fracturas Conminutas/cirugía , Fracturas Conminutas/diagnóstico por imagen , Adulto , Estudios Retrospectivos , Fracturas Intraarticulares/cirugía , Fracturas Intraarticulares/diagnóstico por imagen , Rango del Movimiento Articular
15.
Acta Orthop Belg ; 90(1): 102-109, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38669658

RESUMEN

In 2020, the most common treatment for presumed aseptic non-union of the humeral shaft seems to be decortication, often associated with bone autografting, and stabilized by a screw plate. We propose to evaluate an original technique of rigid osteosynthesis combining intramedullary nailing and screw plate. Between January 2004 and January 2020, 45 patients underwent treatment of presumed aseptic non-union of the humeral shaft by osteosynthesis combining intramedullary nailing and a screw plate. The minimum radio-clinical follow-up was one year postoperatively. The series included 19 men and 26 women with a mean age of 53 years (range 19-84 years). Bone consolidation was achieved in 43 patients, a rate of 95.5%. Comparing patients who achieved bone consolidation with the two failed consolidations did not reveal any statistically significant factor. Interobserver agreement was almost perfect (k=0.93) for the use of the RUST for humeral shaft fractures treated with intramedullary nailing and screw plate. In our study, the treatment of presumed aseptic non- union of the humeral shaft with an osteosynthesis combining intramedullary nailing and screw plate gives, with 95.5% of bone consolidation, results equal to or even superior to the different treatments currently described in the literature.


Asunto(s)
Placas Óseas , Tornillos Óseos , Fijación Intramedular de Fracturas , Fracturas no Consolidadas , Fracturas del Húmero , Humanos , Persona de Mediana Edad , Masculino , Adulto , Femenino , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Anciano , Fracturas del Húmero/cirugía , Anciano de 80 o más Años , Fracturas no Consolidadas/cirugía , Adulto Joven , Estudios Retrospectivos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Curación de Fractura
16.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38792901

RESUMEN

Background and Objectives: This retrospective cohort study analyzes mechanical complications in hip fracture surgery using the Trochanteric Fixation Nail-Advanced (TFNA) implant. It investigates the correlation of these complications with demographic, intraoperative, and radiological factors, aiming to identify associated risk factors and suggest improvements in clinical surveillance and treatment strategies. Materials and Methods: We enrolled 253 patients diagnosed with pertrochanteric hip fractures treated between 2017 and 2021, with 126 meeting the criteria for a minimum 6-month follow-up. Data on demographics, American Anesthesia Association Classification (ASA), comorbidities, AO/OTA [AO (Arbeitsgemeinschaft für Osteosynthesefragen)/OTA (Orthopedic Trauma Association)] fracture classification, procedural details, and time to failure were collected. Radiographs were evaluated for reduction quality, the tip-apex distance (TAD), progressive varus deviation, and identification of mechanical complications. Statistical analysis was performed using SPSS software. Results: The predominant AO/OTA fracture classification was 31A2 in 67 cases (52.7%). Reduction quality was deemed good or acceptable in 123 cases (97.6%). The mean time to failure was 4.5 months (range: 2.2-6). The average TAD was 18 mm (range: 1.2-36), with a mean progressive varus deviation of 2.44° (range: 1.30-4.14). A good or acceptable reduction quality was observed in 97.6% of cases. Mechanical complications occurred in 21.4% of patients, with significant associations found with the lateral cortex fracture, use of a TFNA implant with a 130° angle, open reduction, and absence of prior osteoporosis treatment. Conclusions: The study provides insights into mechanical complications in proximal femur fractures treated with the TFNA nail, emphasizing the need for enhanced clinical and radiographic surveillance, especially in patients without osteoporosis treatment. Our findings support the necessity for further clinical studies comparing these outcomes with other implant designs and underscore the importance of personalized treatment strategies to reduce complication rates.


Asunto(s)
Fijación Intramedular de Fracturas , Complicaciones Posoperatorias , Humanos , Estudios Retrospectivos , Femenino , Masculino , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/instrumentación , Anciano , Anciano de 80 o más Años , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Fracturas de Cadera/cirugía , Clavos Ortopédicos , Estudios de Cohortes , Fracturas del Fémur/cirugía , Factores de Riesgo , Fracturas Femorales Proximales
17.
Eur J Orthop Surg Traumatol ; 34(4): 2073-2079, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38530503

RESUMEN

PURPOSE: Intra-articular distal femur fractures in patients with a lower extremity amputation can present a technical challenge for the treating surgeon in what may be otherwise considered a routine procedure in non-amputees. Difficulties with positioning, fracture reduction, limb contractures, and stump osteoporosis can present challenges with treatment. Here, we describe the surgical technique and outcome of a case series of amputee patients with AO/OTA 33C femur fractures. METHODS: Retrospective case series of five patients with a comminuted supracondylar distal femur fracture with intercondylar extension proximal to a below-knee amputation treated with retrograde intramedullary nail at a single Level 1 trauma center from January 1, 2021, to January 1, 2023. Baseline demographic and clinical data were recorded. Rate of bony union and complications were documented. RESULTS: Five patients (three females and two males) with a mean age of 48 years who were treated for a comminuted supracondylar distal femur fracture with intercondylar extension proximal to a below-knee amputation were identified. At the time of final follow-up (mean 109.3 days, range 29-183 days), all patients had healed their incisions and were progressing to return of function with their prosthesis. All patients were treated with the surgical technique described in this article, and no postoperative complications were reported. CONCLUSION: This is an effective and safe technique for surgical treatment of comminuted intra-articular distal femur fractures in patients with an ipsilateral below-knee amputation. We believe that this technique can be utilized by any orthopedic surgeon taking trauma call and can avoid unnecessary transfers or delays to care.


Asunto(s)
Amputación Quirúrgica , Fracturas del Fémur , Fijación Intramedular de Fracturas , Fracturas Conminutas , Humanos , Fracturas del Fémur/cirugía , Femenino , Masculino , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/instrumentación , Persona de Mediana Edad , Estudios Retrospectivos , Adulto , Fracturas Conminutas/cirugía , Amputación Quirúrgica/métodos , Clavos Ortopédicos , Resultado del Tratamiento , Curación de Fractura , Anciano
18.
Eur J Orthop Surg Traumatol ; 34(5): 2779-2784, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38771370

RESUMEN

PURPOSE: Intertrochanteric fractures are treated surgically, allowing rapid weight-bearing to improve ambulation and lower complications and mortality. Subtrochanteric fractures are mechanically less stable and are traditionally treated with a non-weight approach and longer intramedullary nails. This study compared immediate weight-bearing versus limited weight-bearing and different intramedullary nail lengths regarding patient outcomes. METHODS: We analyzed all consecutive cases of low-energy subtrochanteric fractures treated surgically at our institution between January 2016 and November 2020. One hundred and nine patients were found. We compared nail length and immediate versus delayed weight-bearing concerning the length of stay, time to painless ambulation, time to radiographic fracture union, and revision rates. Fracture severity was also examined using the Seinsheimer classification. RESULTS: Length of stay and time to painless ambulation were shorter in the immediate weight-bearing group. Time to radiographic union and rate of complications were lower; however, they were not statistically significant. Conversely, no significant difference in revision rates was found. Regarding nail length, the length of stay was shorter, and the time to painless ambulation was faster in the short-length group. The rate of complications and time to union were similar. No difference in revision rate was found. Seinsheimer classification of the fracture did not influence the decision to allow weight-bearing or nail selection (p = 0.65). CONCLUSIONS: This study demonstrates that immediate weight-bearing as tolerated and short intramedullary nails allow a quicker time for painless ambulation and hospitalization, with possibly fewer perioperative complications and faster radiographic union, without increasing complications.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Fracturas de Cadera , Tiempo de Internación , Complicaciones Posoperatorias , Soporte de Peso , Humanos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/métodos , Femenino , Masculino , Fracturas de Cadera/cirugía , Anciano , Tiempo de Internación/estadística & datos numéricos , Complicaciones Posoperatorias/etiología , Anciano de 80 o más Años , Persona de Mediana Edad , Estudios Retrospectivos , Reoperación/estadística & datos numéricos , Curación de Fractura
19.
Eur J Orthop Surg Traumatol ; 34(3): 1259-1267, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38145978

RESUMEN

PURPOSE: The purpose of this meta-analysis is to analyse the literature on plate-assisted reduction during intramedullary nailing of tibial shaft fractures and to compare the rates of infection and nonunion. METHODS: The databases Medline, Embase, and Web of Science were searched from inception to February 2022 for literature comparing plate-assisted reduction during intramedullary nailing of extra-articular tibia fractures to standard, closed means of reduction. Data were extracted and pooled in a random effects meta-analysis for the primary outcomes of nonunion and infection risk. RESULTS: Five comparative studies were identified including 520 total patients, of which 151 underwent tibial nailing with the use of plate-assisted reduction with an average follow-up time of 17.9 months. Approximately two-thirds of patients retained the plate used to assist reduction during intramedullary nailing (102 of 151). Pooled analysis of the infection rates found no significant difference with plate-assisted intramedullary nailing (Risk Ratio [RR] 0.90, 95% CI 0.49-1.65, p = 0.72), and for nonunion rates, there was also no significant difference with plate-assisted intramedullary nailing (Risk Ratio [RR] 0.80, 95% CI 0.40-1.60, p = 0.53). CONCLUSIONS: Plate-assisted reduction during intramedullary nailing of tibia shaft fractures was not associated with an increased risk for nonunion or infection, and can be safely applied as an adjunct for reduction in challenging fracture patterns, without the need for later removal. However, evidence is quite limited and further investigation into the use of provisional plating as a technique is needed as its use in intramedullary nailing continues to expand.


Asunto(s)
Placas Óseas , Fijación Intramedular de Fracturas , Fracturas de la Tibia , Fracturas de la Tibia/cirugía , Humanos , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Fracturas no Consolidadas/cirugía , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/etiología
20.
Eur J Orthop Surg Traumatol ; 34(5): 2595-2603, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38703201

RESUMEN

PURPOSE: Biomechanical superiority of intramedullary nails over extramedullary implants has been proved for subtrochanteric fractures. Nevertheless, postoperative management of these patients has not changed, with high rates of protected weight-bearing after intramedullary nailing. The purpose of this study is to determine the mechanical complications of immediate postoperative full weigh-bearing for subtrochanteric femur fractures in elderly patients treated with a cephalomedullary nail. METHODS: We performed a retrospective case series study from patients treated with a cephalomedullary nail for subtrochanteric fractures (AO/OTA 31A.3 and 32A-32C) over a nine-year period. Patients in the immediate full weight-bearing (IFWB) group received orders for immediate full weight bear as tolerated on postoperative 48 h. Patients in the non- or limited- weight-bearing (NLWB) group received orders not to full weight bear in the immediate postoperative. RESULTS: There were five (2.7%) cases of implant failure including four cutouts and one nail breakage that needed a reoperation. Of them, one (2.2%) followed the NLWB protocol and four (2.9%) followed the IFWB protocol. Mean length of stay was 7.9 days (median 8, range 3-21) in the NLWB group and 10.7 days (median 8, range 2-60) in the IWBAT group. The NLWB group observed a 2.8-day shorter postoperative length of stay when compared to the IFWB, but the median remained equal. CONCLUSION: This study suggests that geriatric patients with subtrochanteric fractures treated by intramedullary nailing and in which a good fracture reduction was achieved, may be able to tolerate immediate postoperative full weight-bearing, not increasing reoperation rates due to implant failure.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Fracturas de Cadera , Soporte de Peso , Humanos , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Femenino , Masculino , Estudios Retrospectivos , Fracturas de Cadera/cirugía , Anciano , Anciano de 80 o más Años , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Reoperación/estadística & datos numéricos , Falla de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA