Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 610(7931): 277-282, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36224415

RESUMO

Personalized exoskeleton assistance provides users with the largest improvements in walking speed1 and energy economy2-4 but requires lengthy tests under unnatural laboratory conditions. Here we show that exoskeleton optimization can be performed rapidly and under real-world conditions. We designed a portable ankle exoskeleton based on insights from tests with a versatile laboratory testbed. We developed a data-driven method for optimizing exoskeleton assistance outdoors using wearable sensors and found that it was equally effective as laboratory methods, but identified optimal parameters four times faster. We performed real-world optimization using data collected during many short bouts of walking at varying speeds. Assistance optimized during one hour of naturalistic walking in a public setting increased self-selected speed by 9 ± 4% and reduced the energy used to travel a given distance by 17 ± 5% compared with normal shoes. This assistance reduced metabolic energy consumption by 23 ± 8% when participants walked on a treadmill at a standard speed of 1.5 m s-1. Human movements encode information that can be used to personalize assistive devices and enhance performance.


Assuntos
Exoesqueleto Energizado , Caminhada , Tornozelo , Articulação do Tornozelo , Humanos , Velocidade de Caminhada
2.
PLoS Comput Biol ; 19(8): e1010712, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37549183

RESUMO

Walking balance is central to independent mobility, and falls due to loss of balance are a leading cause of death for people 65 years of age and older. Bipedal gait is typically unstable, but healthy humans use corrective torques to counteract perturbations and stabilize gait. Exoskeleton assistance could benefit people with neuromuscular deficits by providing stabilizing torques at lower-limb joints to replace lost muscle strength and sensorimotor control. However, it is unclear how applied exoskeleton torques translate to changes in walking kinematics. This study used musculoskeletal simulation to investigate how exoskeleton torques applied to the ankle and subtalar joints alter center of mass kinematics during walking. We first created muscle-driven walking simulations using OpenSim Moco by tracking experimental kinematics and ground reaction forces recorded from five healthy adults. We then used forward integration to simulate the effect of exoskeleton torques applied to the ankle and subtalar joints while keeping muscle excitations fixed based on our previous tracking simulation results. Exoskeleton torque lasted for 15% of the gait cycle and was applied between foot-flat and toe-off during the stance phase, and changes in center of mass kinematics were recorded when the torque application ended. We found that changes in center of mass kinematics were dependent on both the type and timing of exoskeleton torques. Plantarflexion torques produced upward and backward changes in velocity of the center of mass in mid-stance and upward and smaller forward velocity changes near toe-off. Eversion and inversion torques primarily produced lateral and medial changes in velocity in mid-stance, respectively. Intrinsic muscle properties reduced kinematic changes from exoskeleton torques. Our results provide mappings between ankle plantarflexion and inversion-eversion torques and changes in center of mass kinematics which can inform designers building exoskeletons aimed at stabilizing balance during walking. Our simulations and software are freely available and allow researchers to explore the effects of applied torques on balance and gait.


Assuntos
Tornozelo , Exoesqueleto Energizado , Adulto , Humanos , Torque , Fenômenos Biomecânicos/fisiologia , Caminhada/fisiologia , Marcha/fisiologia
3.
J Neuroeng Rehabil ; 21(1): 1, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167151

RESUMO

BACKGROUND: Walking speed and energy economy tend to decline with age. Lower-limb exoskeletons have demonstrated potential to improve either measure, but primarily in studies conducted on healthy younger adults. Promising techniques like optimization of exoskeleton assistance have yet to be tested with older populations, while speed and energy consumption have yet to be simultaneously optimized for any population. METHODS: We investigated the effectiveness of human-in-the-loop optimization of ankle exoskeletons with older adults. Ten healthy adults > 65 years of age (5 females; mean age: 72 ± 3 yrs) participated in approximately 240 min of training and optimization with tethered ankle exoskeletons on a self-paced treadmill. Multi-objective human-in-the-loop optimization was used to identify assistive ankle plantarflexion torque patterns that simultaneously improved self-selected walking speed and metabolic rate. The effects of optimized exoskeleton assistance were evaluated in separate trials. RESULTS: Optimized exoskeleton assistance improved walking performance for older adults. Both objectives were simultaneously improved; self-selected walking speed increased by 8% (0.10 m/s; p = 0.001) and metabolic rate decreased by 19% (p = 0.007), resulting in a 25% decrease in energetic cost of transport (p = 8e-4) compared to walking with exoskeletons applying zero torque. Compared to younger participants in studies optimizing a single objective, our participants required lower exoskeleton torques, experienced smaller improvements in energy use, and required more time for motor adaptation. CONCLUSIONS: Our results confirm that exoskeleton assistance can improve walking performance for older adults and show that multiple objectives can be simultaneously addressed through human-in-the-loop optimization.


Assuntos
Exoesqueleto Energizado , Feminino , Humanos , Idoso , Velocidade de Caminhada , Eletromiografia/métodos , Fenômenos Biomecânicos , Tornozelo , Articulação do Tornozelo , Caminhada , Marcha
4.
J Neuroeng Rehabil ; 19(1): 46, 2022 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-35549977

RESUMO

BACKGROUND: Reducing the energy cost of running with exoskeletons could improve enjoyment, reduce fatigue, and encourage participation among novice and ageing runners. Previously, tethered ankle exoskeleton emulators with offboard motors were used to greatly reduce the energy cost of running with powered ankle plantarflexion assistance. Through a process known as "human-in-the-loop optimization", the timing and magnitude of assistance torque was optimized to maximally reduce metabolic cost. However, to achieve the maximum net benefit in energy cost outside of the laboratory environment, it is also necessary to consider the tradeoff between the magnitude of device assistance and the metabolic penalty of carrying a heavier, more powerful exoskeleton. METHODS: In this study, tethered ankle exoskeleton emulators were used to characterize the effect of peak assistance torque on metabolic cost during running. Three recreational runners participated in human-in-the-loop optimization at four fixed peak assistance torque levels to obtain their energetically optimal assistance timing parameters at each level. RESULTS: We found that the relationship between metabolic rate and peak assistance torque was nearly linear but with diminishing returns at higher torque magnitudes, which is well-approximated by an asymptotic exponential function. At the highest assistance torque magnitude of 0.8 Nm/kg, participants' net metabolic rate was 24.8 ± 2.3% (p = 4e-6) lower than running in the unpowered devices. Optimized timing of peak assistance torque was as late as allowed during stance (80% of stance) and optimized timing of torque removal was at toe-off (100% of stance); similar assistance timing was preferred across participants and torque magnitudes. CONCLUSIONS: These results allow exoskeleton designers to predict the energy cost savings for candidate devices with different assistance torque capabilities, thus informing the design of portable ankle exoskeletons that maximize net metabolic benefit.


Assuntos
Exoesqueleto Energizado , Tornozelo , Articulação do Tornozelo , Fenômenos Biomecânicos , Metabolismo Energético , Marcha , Humanos , Torque , Caminhada
5.
J Prosthet Orthot ; 34(4): 202-212, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36157327

RESUMO

Introduction: The design and selection of lower-limb prosthetic devices is currently hampered by a shortage of evidence to drive the choice of prosthetic foot parameters. We propose a new approach wherein prostheses could be designed, specified, and provided based on individualized measurements of the benefits provided by candidate feet. In this manuscript, we present a pilot test of this evidence-based and personalized process. Methods: We previously developed a "prosthetic foot emulator," a wearable robotic system that provides users with the physical sensation of trying on different prosthetic feet before definitive fitting. Here we detail preliminary demonstrations of two possible approaches to personalizing foot design: 1) an emulation and test-drive strategy of representative commercial foot models, and 2) a prosthetist-driven tuning procedure to optimize foot parameters. Results: The first experiment demonstrated large and sometimes surprising differences in optimal prosthetic foot parameters across a variety of subjects, walking conditions, and outcome measures. The second experiment demonstrated a quick and effective simple manual tuning procedure for identifying preferred prosthetic foot parameters. Conclusions: Emulator-based approaches could improve individualization of prosthetic foot prescription. The present results motivate future clinical studies of the validity, efficacy, and economics of the approach across larger and more diverse subject populations. Clinical Relevance: Today, emulator technology is being used to accelerate research and development of novel prosthetic and orthotic devices. In the future, after further refinement and validation, this technology could benefit clinical practice by providing a means for rapid test-driving and optimal selection of clinically available prosthetic feet.

6.
Nature ; 522(7555): 212-5, 2015 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-25830889

RESUMO

With efficiencies derived from evolution, growth and learning, humans are very well-tuned for locomotion. Metabolic energy used during walking can be partly replaced by power input from an exoskeleton, but is it possible to reduce metabolic rate without providing an additional energy source? This would require an improvement in the efficiency of the human-machine system as a whole, and would be remarkable given the apparent optimality of human gait. Here we show that the metabolic rate of human walking can be reduced by an unpowered ankle exoskeleton. We built a lightweight elastic device that acts in parallel with the user's calf muscles, off-loading muscle force and thereby reducing the metabolic energy consumed in contractions. The device uses a mechanical clutch to hold a spring as it is stretched and relaxed by ankle movements when the foot is on the ground, helping to fulfil one function of the calf muscles and Achilles tendon. Unlike muscles, however, the clutch sustains force passively. The exoskeleton consumes no chemical or electrical energy and delivers no net positive mechanical work, yet reduces the metabolic cost of walking by 7.2 ± 2.6% for healthy human users under natural conditions, comparable to savings with powered devices. Improving upon walking economy in this way is analogous to altering the structure of the body such that it is more energy-effective at walking. While strong natural pressures have already shaped human locomotion, improvements in efficiency are still possible. Much remains to be learned about this seemingly simple behaviour.


Assuntos
Membros Artificiais , Biônica/instrumentação , Biônica/métodos , Metabolismo Energético , Caminhada/fisiologia , Tornozelo/fisiologia , Feminino , Pé/fisiologia , Humanos , Perna (Membro)/fisiologia , Masculino , Músculo Esquelético/fisiologia , Adulto Jovem
7.
J Neuroeng Rehabil ; 18(1): 161, 2021 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-34743714

RESUMO

BACKGROUND: Load carriage is common in a wide range of professions, but prolonged load carriage is associated with increased fatigue and overuse injuries. Exoskeletons could improve the quality of life of these professionals by reducing metabolic cost to combat fatigue and reducing muscle activity to prevent injuries. Current exoskeletons have reduced the metabolic cost of loaded walking by up to 22% relative to walking in the device with no assistance when assisting one or two joints. Greater metabolic reductions may be possible with optimized assistance of the entire leg. METHODS: We used human-in the-loop optimization to optimize hip-knee-ankle exoskeleton assistance with no additional load, a light load (15% of body weight), and a heavy load (30% of body weight) for three participants. All loads were applied through a weight vest with an attached waist belt. We measured metabolic cost, exoskeleton assistance, kinematics, and muscle activity. We performed Friedman's tests to analyze trends across worn loads and paired t-tests to determine whether changes from the unassisted conditions to the assisted conditions were significant. RESULTS: Exoskeleton assistance reduced the metabolic cost of walking relative to walking in the device without assistance for all tested conditions. Exoskeleton assistance reduced the metabolic cost of walking by 48% with no load (p = 0.05), 41% with the light load (p = 0.01), and 43% with the heavy load (p = 0.04). The smaller metabolic reduction with the light load may be due to insufficient participant training or lack of optimizer convergence. The total applied positive power was similar for all tested conditions, and the positive knee power decreased slightly as load increased. Optimized torque timing parameters were consistent across participants and load conditions while optimized magnitude parameters varied. CONCLUSIONS: Whole-leg exoskeleton assistance can reduce the metabolic cost of walking while carrying a range of loads. The consistent optimized timing parameters across participants and conditions suggest that metabolic cost reductions are sensitive to torque timing. The variable torque magnitude parameters could imply that torque magnitude should be customized to the individual, or that there is a range of useful torque magnitudes. Future work should test whether applying the load to the exoskeleton rather than the person's torso results in larger benefits.


Assuntos
Exoesqueleto Energizado , Tornozelo/fisiologia , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos/fisiologia , Metabolismo Energético/fisiologia , Humanos , Qualidade de Vida , Caminhada/fisiologia
8.
J Neuroeng Rehabil ; 18(1): 152, 2021 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-34663372

RESUMO

BACKGROUND: Autonomous exoskeletons will need to be useful at a variety of walking speeds, but it is unclear how optimal hip-knee-ankle exoskeleton assistance should change with speed. Biological joint moments tend to increase with speed, and in some cases, optimized ankle exoskeleton torques follow a similar trend. Ideal hip-knee-ankle exoskeleton torque may also increase with speed. The purpose of this study was to characterize the relationship between walking speed, optimal hip-knee-ankle exoskeleton assistance, and the benefits to metabolic energy cost. METHODS: We optimized hip-knee-ankle exoskeleton assistance to reduce metabolic cost for three able-bodied participants walking at 1.0 m/s, 1.25 m/s and 1.5 m/s. We measured metabolic cost, muscle activity, exoskeleton assistance and kinematics. We performed Friedman's tests to analyze trends across walking speeds and paired t-tests to determine if changes from the unassisted conditions to the assisted conditions were significant. RESULTS: Exoskeleton assistance reduced the metabolic cost of walking compared to wearing the exoskeleton with no torque applied by 26%, 47% and 50% at 1.0, 1.25 and 1.5 m/s, respectively. For all three participants, optimized exoskeleton ankle torque was the smallest for slow walking, while hip and knee torque changed slightly with speed in ways that varied across participants. Total applied positive power increased with speed for all three participants, largely due to increased joint velocities, which consistently increased with speed. CONCLUSIONS: Exoskeleton assistance is effective at a range of speeds and is most effective at medium and fast walking speeds. Exoskeleton assistance was less effective for slow walking, which may explain the limited success in reducing metabolic cost for patient populations through exoskeleton assistance. Exoskeleton designers may have more success when targeting activities and groups with faster walking speeds. Speed-related changes in optimized exoskeleton assistance varied by participant, indicating either the benefit of participant-specific tuning or that a wide variety of torque profiles are similarly effective.


Assuntos
Exoesqueleto Energizado , Velocidade de Caminhada , Tornozelo , Articulação do Tornozelo , Fenômenos Biomecânicos , Marcha , Humanos , Caminhada
9.
J Biomech Eng ; 142(9)2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32280955

RESUMO

Prosthesis features that enhance balance are desirable to people with transtibial amputation. Ankle inversion/eversion compliance is intended to improve balance on uneven ground, but its effects remain unclear on level ground. We posited that increasing ankle inversion/eversion stiffness during level-ground walking would reduce balance-related effort by assisting in recovery from small disturbances in frontal-plane motions. We performed a pilot test with an ankle-foot prosthesis emulator programmed to apply inversion/eversion torques in proportion to the deviation from a nominal inversion/eversion position trajectory. We applied a range of stiffnesses to clearly understand the effect of the stiffness on balance-related effort, hypothesizing that positive stiffness would reduce effort while negative stiffness would increase effort. Nominal joint angle trajectories were calculated online as a moving average over several steps. In experiments with K3 ambulators with unilateral transtibial amputation (N = 5), stiffness affected step-width variability, average step width, margin of stability, intact-foot center of pressure variability, and user satisfaction (p ≤ 0.05, Friedman's test), but not intact-limb evertor average, intact-limb evertor variability, and metabolic rate (p ≥ 0.38, Friedman's test). Compared to zero stiffness, high positive stiffness reduced step-width variability by 13%, step width by 3%, margin of stability by 3%, and intact-foot center of pressure variability by 14%, whereas high negative stiffness had opposite effects and decreased satisfaction by 63%. The results of this pilot study suggest that positive ankle inversion stiffness can reduce active control requirements during level walking.


Assuntos
Membros Artificiais , Fenômenos Biomecânicos , Marcha , Projetos Piloto
10.
J Neuroeng Rehabil ; 17(1): 68, 2020 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-32493426

RESUMO

BACKGROUND: Self-selected speed is an important functional index of walking. A self-pacing controller that reliably matches walking speed without additional hardware can be useful for measuring self-selected speed in a treadmill-based laboratory. METHODS: We adapted a previously proposed self-pacing controller for force-instrumented treadmills and validated its use for measuring self-selected speeds. We first evaluated the controller's estimation of subject speed and position from the force-plates by comparing it to those from motion capture data. We then compared five tests of self-selected speed. Ten healthy adults completed a standard 10-meter walk test, a 150-meter walk test, a commonly used manual treadmill speed selection test, a two-minute self-paced treadmill test, and a 150-meter self-paced treadmill test. In each case, subjects were instructed to walk at or select their comfortable speed. We also assessed the time taken for a trial and a survey on comfort and ease of choosing a speed in all the tests. RESULTS: The self-pacing algorithm estimated subject speed and position accurately, with root mean square differences compared to motion capture of 0.023 m s -1 and 0.014 m, respectively. Self-selected speeds from both self-paced treadmill tests correlated well with those from the 10-meter walk test (R>0.93,p<1×10-13). Subjects walked slower on average in the self-paced treadmill tests (1.23±0.27 ms-1) than in the 10-meter walk test (1.32±0.18 ms-1) but the speed differences within subjects were consistent. These correlations and walking speeds are comparable to those from the manual treadmill speed selection test (R=0.89,p=3×10-11;1.18±0.24 ms-1). Comfort and ease of speed selection were similar in the self-paced tests and the manual speed selection test, but the self-paced tests required only about a third of the time to complete. Our results demonstrate that these self-paced treadmill tests can be a strong alternative to the commonly used manual treadmill speed selection test. CONCLUSIONS: The self-paced force-instrumented treadmill well adapts to subject walking speed and reliably measures self-selected walking speeds. We provide the self-pacing software to facilitate use by gait researchers and clinicians.


Assuntos
Algoritmos , Teste de Esforço/instrumentação , Velocidade de Caminhada , Adulto , Teste de Esforço/métodos , Feminino , Humanos , Masculino
11.
J Neuroeng Rehabil ; 17(1): 119, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32847596

RESUMO

BACKGROUND: Asymmetric gait post-stroke is associated with decreased mobility, yet individuals with chronic stroke often self-select an asymmetric gait despite being capable of walking more symmetrically. The purpose of this study was to test whether self-selected asymmetry could be explained by energy cost minimization. We hypothesized that short-term deviations from self-selected asymmetry would result in increased metabolic energy consumption, despite being associated with long-term rehabilitation benefits. Other studies have found no difference in metabolic rate across different levels of enforced asymmetry among individuals with chronic stroke, but used methods that left some uncertainty to be resolved. METHODS: In this study, ten individuals with chronic stroke walked on a treadmill at participant-specific speeds while voluntarily altering step length asymmetry. We included only participants with clinically relevant self-selected asymmetry who were able to significantly alter asymmetry using visual biofeedback. Conditions included targeting zero asymmetry, self-selected asymmetry, and double the self-selected asymmetry. Participants were trained with the biofeedback system in one session, and data were collected in three subsequent sessions with repeated measures. Self-selected asymmetry was consistent across sessions. A similar protocol was conducted among unimpaired participants. RESULTS: Participants with chronic stroke substantially altered step length asymmetry using biofeedback, but this did not affect metabolic rate (ANOVA, p = 0.68). In unimpaired participants, self-selected step length asymmetry was close to zero and corresponded to the lowest metabolic energy cost (ANOVA, p = 6e-4). While the symmetry of unimpaired gait may be the result of energy cost minimization, self-selected step length asymmetry in individuals with chronic stroke cannot be explained by a similar least-effort drive. CONCLUSIONS: Interventions that encourage changes in step length asymmetry by manipulating metabolic energy consumption may be effective because these therapies would not have to overcome a metabolic penalty for altering asymmetry.


Assuntos
Metabolismo Energético/fisiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Acidente Vascular Cerebral/fisiopatologia , Idoso , Biorretroalimentação Psicológica , Feminino , Marcha/fisiologia , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/complicações
12.
J Neuroeng Rehabil ; 16(1): 67, 2019 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-31171003

RESUMO

BACKGROUND: Estimating energy expenditure with indirect calorimetry requires expensive equipment and several minutes of data collection for each condition of interest. While several methods estimate energy expenditure using correlation to data from wearable sensors, such as heart rate monitors or accelerometers, their accuracy has not been evaluated for activity conditions or subjects not included in the correlation process. The goal of our study was to develop data-driven models to estimate energy expenditure at intervals of approximately one second and demonstrate their ability to predict energetic cost for new conditions and subjects. Model inputs were muscle activity and vertical ground reaction forces, which are measurable by wearable electromyography electrodes and pressure sensing insoles. METHODS: We developed models that estimated energy expenditure while walking (1) with ankle exoskeleton assistance and (2) while carrying various loads and walking on inclines. Estimates were made each gait cycle or four second interval. We evaluated the performance of the models for three use cases. The first estimated energy expenditure (in Watts) during walking conditions for subjects with some subject specific training data available. The second estimated all conditions in the dataset for a new subject not included in the training data. The third estimated new conditions for a new subject. RESULTS: The mean absolute percent errors in estimated energy expenditure during assisted walking conditions were 4.4%, 8.0%, and 8.1% for the three use cases, respectively. The average errors in energy expenditure estimation during inclined and loaded walking conditions were 6.1%, 9.7%, and 11.7% for the three use cases. For models not using subject-specific data, we evaluated the ability to order the magnitude of energy expenditure across conditions. The average percentage of correctly ordered conditions was 63% for assisted walking and 87% for incline and loaded walking. CONCLUSIONS: We have determined the accuracy of estimating energy expenditure with data-driven models that rely on ground reaction forces and muscle activity for three use cases. For experimental use cases where the accuracy of a data-driven model is sufficient and similar training data is available, standard indirect calorimetry could be replaced. The models, code, and datasets are provided for reproduction and extension of our results.


Assuntos
Metabolismo Energético/fisiologia , Exoesqueleto Energizado , Redes Neurais de Computação , Adulto , Articulação do Tornozelo/fisiologia , Eletromiografia , Feminino , Humanos , Masculino , Caminhada/fisiologia
13.
J Exp Biol ; 220(Pt 11): 2082-2095, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28341663

RESUMO

The goal of this study was to gain insight into how ankle exoskeletons affect the behavior of the plantarflexor muscles during walking. Using data from previous experiments, we performed electromyography-driven simulations of musculoskeletal dynamics to explore how changes in exoskeleton assistance affected plantarflexor muscle-tendon mechanics, particularly for the soleus. We used a model of muscle energy consumption to estimate individual muscle metabolic rate. As average exoskeleton torque was increased, while no net exoskeleton work was provided, a reduction in tendon recoil led to an increase in positive mechanical work performed by the soleus muscle fibers. As net exoskeleton work was increased, both soleus muscle fiber force and positive mechanical work decreased. Trends in the sum of the metabolic rates of the simulated muscles correlated well with trends in experimentally observed whole-body metabolic rate (R2=0.9), providing confidence in our model estimates. Our simulation results suggest that different exoskeleton behaviors can alter the functioning of the muscles and tendons acting at the assisted joint. Furthermore, our results support the idea that the series tendon helps reduce positive work done by the muscle fibers by storing and returning energy elastically. We expect the results from this study to promote the use of electromyography-driven simulations to gain insight into the operation of muscle-tendon units and to guide the design and control of assistive devices.


Assuntos
Exoesqueleto Energizado , Músculo Esquelético/metabolismo , Caminhada/fisiologia , Adulto , Tornozelo/fisiologia , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos/fisiologia , Simulação por Computador , Eletromiografia , Metabolismo Energético/fisiologia , Feminino , Humanos , Masculino , Tendões/fisiologia , Torque
14.
J Neuroeng Rehabil ; 12: 43, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25928176

RESUMO

BACKGROUND: Individuals with below-knee amputation have more difficulty balancing during walking, yet few studies have explored balance enhancement through active prosthesis control. We previously used a dynamical model to show that prosthetic ankle push-off work affects both sagittal and frontal plane dynamics, and that appropriate step-by-step control of push-off work can improve stability. We hypothesized that this approach could be applied to a robotic prosthesis to partially fulfill the active balance requirements of human walking, thereby reducing balance-related activity and associated effort for the person using the device. METHODS: We conducted experiments on human participants (N = 10) with simulated amputation. Prosthetic ankle push-off work was varied on each step in ways expected to either stabilize, destabilize or have no effect on balance. Average ankle push-off work, known to affect effort, was kept constant across conditions. Stabilizing controllers commanded more push-off work on steps when the mediolateral velocity of the center of mass was lower than usual at the moment of contralateral heel strike. Destabilizing controllers enforced the opposite relationship, while a neutral controller maintained constant push-off work regardless of body state. A random disturbance to landing foot angle and a cognitive distraction task were applied, further challenging participants' balance. We measured metabolic rate, foot placement kinematics, center of pressure kinematics, distraction task performance, and user preference in each condition. We expected the stabilizing controller to reduce active control of balance and balance-related effort for the user, improving user preference. RESULTS: The best stabilizing controller lowered metabolic rate by 5.5% (p = 0.003) and 8.5% (p = 0.02), and step width variability by 10.0% (p = 0.009) and 10.7% (p = 0.03) compared to conditions with no control and destabilizing control, respectively. Participants tended to prefer stabilizing controllers. These effects were not due to differences in average push-off work, which was unchanged across conditions, or to average gait mechanics, which were also unchanged. Instead, benefits were derived from step-by-step adjustments to prosthesis behavior in response to variations in mediolateral velocity at heel strike. CONCLUSIONS: Once-per-step control of prosthetic ankle push-off work can reduce both active control of foot placement and balance-related metabolic energy use during walking.


Assuntos
Membros Artificiais , Fenômenos Biomecânicos , Prótese Articular , Equilíbrio Postural/fisiologia , Robótica/instrumentação , Adulto , Articulação do Tornozelo/fisiologia , Metabolismo Energético/fisiologia , Feminino , Marcha/fisiologia , Humanos , Masculino , Caminhada/fisiologia , Adulto Jovem
15.
J Neuroeng Rehabil ; 12: 21, 2015 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-25889201

RESUMO

BACKGROUND: Robotic ankle-foot prostheses that provide net positive push-off work can reduce the metabolic rate of walking for individuals with amputation, but benefits might be sensitive to push-off timing. Simple walking models suggest that preemptive push-off reduces center-of-mass work, possibly reducing metabolic rate. Studies with bilateral exoskeletons have found that push-off beginning before leading leg contact minimizes metabolic rate, but timing was not varied independently from push-off work, and the effects of push-off timing on biomechanics were not measured. Most lower-limb amputations are unilateral, which could also affect optimal timing. The goal of this study was to vary the timing of positive prosthesis push-off work in isolation and measure the effects on energetics, mechanics and muscle activity. METHODS: We tested 10 able-bodied participants walking on a treadmill at 1.25 m · s(-1). Participants wore a tethered ankle-foot prosthesis emulator on one leg using a rigid boot adapter. We programmed the prosthesis to apply torque bursts that began between 46% and 56% of stride in different conditions. We iteratively adjusted torque magnitude to maintain constant net positive push-off work. RESULTS: When push-off began at or after leading leg contact, metabolic rate was about 10% lower than in a condition with Spring-like prosthesis behavior. When push-off began before leading leg contact, metabolic rate was not different from the Spring-like condition. Early push-off led to increased prosthesis-side vastus medialis and biceps femoris activity during push-off and increased variability in step length and prosthesis loading during push-off. Prosthesis push-off timing had no influence on intact-side leg center-of-mass collision work. CONCLUSIONS: Prosthesis push-off timing, isolated from push-off work, strongly affected metabolic rate, with optimal timing at or after intact-side heel contact. Increased thigh muscle activation and increased human variability appear to have caused the lack of reduction in metabolic rate when push-off was provided too early. Optimal timing with respect to opposite heel contact was not different from normal walking, but the trends in metabolic rate and center-of-mass mechanics were not consistent with simple model predictions. Optimal push-off timing should also be characterized for individuals with amputation, since meaningful benefits might be realized with improved timing.


Assuntos
Tornozelo/fisiologia , Membros Artificiais , Metabolismo Energético/fisiologia , Pé/fisiologia , Robótica , Caminhada/fisiologia , Algoritmos , Fenômenos Biomecânicos , Biônica , Eletromiografia , Feminino , Marcha/fisiologia , Humanos , Masculino , Fenômenos Mecânicos , Músculo Esquelético/fisiologia , Desenho de Prótese , Torque , Adulto Jovem
16.
J Biomech Eng ; 136(3): 035002, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24337103

RESUMO

Robotic prostheses have the potential to significantly improve mobility for people with lower-limb amputation. Humans exhibit complex responses to mechanical interactions with these devices, however, and computational models are not yet able to predict such responses meaningfully. Experiments therefore play a critical role in development, but have been limited by the use of product-like prototypes, each requiring years of development and specialized for a narrow range of functions. Here we describe a robotic ankle-foot prosthesis system that enables rapid exploration of a wide range of dynamical behaviors in experiments with human subjects. This emulator comprises powerful off-board motor and control hardware, a flexible Bowden cable tether, and a lightweight instrumented prosthesis, resulting in a combination of low mass worn by the human (0.96 kg) and high mechatronic performance compared to prior platforms. Benchtop tests demonstrated closed-loop torque bandwidth of 17 Hz, peak torque of 175 Nm, and peak power of 1.0 kW. Tests with an anthropomorphic pendulum "leg" demonstrated low interference from the tether, less than 1 Nm about the hip. This combination of low worn mass, high bandwidth, high torque, and unrestricted movement makes the platform exceptionally versatile. To demonstrate suitability for human experiments, we performed preliminary tests in which a subject with unilateral transtibial amputation walked on a treadmill at 1.25 ms-1 while the prosthesis behaved in various ways. These tests revealed low torque tracking error (RMS error of 2.8 Nm) and the capacity to systematically vary work production or absorption across a broad range (from -5 to 21 J per step). These results support the use of robotic emulators during early stage assessment of proposed device functionalities and for scientific study of fundamental aspects of human-robot interaction. The design of simple, alternate end-effectors would enable studies at other joints or with additional degrees of freedom.


Assuntos
Articulação do Tornozelo/fisiologia , Tornozelo/fisiologia , Pé/fisiologia , Prótese Articular , Locomoção/fisiologia , Modelos Biológicos , Robótica/instrumentação , Biomimética/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento/instrumentação , Humanos , Desenho de Prótese
17.
Front Robot AI ; 11: 1283080, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357293

RESUMO

Exoskeletons that assist in ankle plantarflexion can improve energy economy in locomotion. Characterizing the joint-level mechanisms behind these reductions in energy cost can lead to a better understanding of how people interact with these devices, as well as to improved device design and training protocols. We examined the biomechanical responses to exoskeleton assistance in exoskeleton users trained with a lengthened protocol. Kinematics at unassisted joints were generally unchanged by assistance, which has been observed in other ankle exoskeleton studies. Peak plantarflexion angle increased with plantarflexion assistance, which led to increased total and biological mechanical power despite decreases in biological joint torque and whole-body net metabolic energy cost. Ankle plantarflexor activity also decreased with assistance. Muscles that act about unassisted joints also increased activity for large levels of assistance, and this response should be investigated over long-term use to prevent overuse injuries.

18.
Sci Robot ; 9(88): eadj7246, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507474

RESUMO

Electric motors are widely used in robots but waste energy in many applications. We introduce an elastic energy-recycling actuator that maintains the versatility of motors while improving energy efficiency in cyclic tasks. The actuator comprises a motor in parallel with an array of springs that can be individually engaged and disengaged, while retaining stored energy, by pairs of low-power electroadhesive clutches. We developed a prototype actuator and tested it in five repetitive tasks with features common in robotic applications but difficult to perform efficiently. The actuator reduced power consumption by at least 50% in all cases and by 97% in the best case. Elastic energy recovery, controlled by low-power clutches, can improve the efficiency of mobile robots, assistive devices, and other engineered systems.

19.
Artigo em Inglês | MEDLINE | ID: mdl-38536680

RESUMO

Exoskeletons are a burgeoning technology with many possible applications to improve human life; focusing the effort of exoskeleton research and development on the most important features is essential for facilitating adoption and maximizing positive societal impact. To identify important focus areas for exoskeleton research and development, we conducted a survey with 154 potential users (older adults) and another survey with 152 clinicians. The surveys were conducted online and to ensure a consistent concept of an exoskeleton across respondents, an image of a hip exoskeleton was shown during exoskeleton-related prompts. The survey responses indicate that both older adults and clinicians are open to using exoskeletons, fall prevention and joint pain reduction are especially important features, and users are likely to wear an exoskeleton in the scenarios when it has the greatest opportunity to help prevent a fall. These findings can help inform future exoskeleton research and guide the development of devices that are accepted, used, and provide meaningful benefit to users.


Assuntos
Exoesqueleto Energizado , Humanos , Idoso , Caminhada/fisiologia , Acidentes por Quedas/prevenção & controle , Extremidade Inferior/fisiologia
20.
bioRxiv ; 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37398034

RESUMO

Creating large-scale public datasets of human motion biomechanics could unlock data-driven breakthroughs in our understanding of human motion, neuromuscular diseases, and assistive devices. However, the manual effort currently required to process motion capture data and quantify the kinematics and dynamics of movement is costly and limits the collection and sharing of large-scale biomechanical datasets. We present a method, called AddBiomechanics, to automate and standardize the quantification of human movement dynamics from motion capture data. We use linear methods followed by a non-convex bilevel optimization to scale the body segments of a musculoskeletal model, register the locations of optical markers placed on an experimental subject to the markers on a musculoskeletal model, and compute body segment kinematics given trajectories of experimental markers during a motion. We then apply a linear method followed by another non-convex optimization to find body segment masses and fine tune kinematics to minimize residual forces given corresponding trajectories of ground reaction forces. The optimization approach requires approximately 3-5 minutes to determine a subjects skeleton dimensions and motion kinematics, and less than 30 minutes of computation to also determine dynamically consistent skeleton inertia properties and fine-tuned kinematics and kinetics, compared with about one day of manual work for a human expert. We used AddBiomechanics to automatically reconstruct joint angle and torque trajectories from previously published multi-activity datasets, achieving close correspondence to expert-calculated values, marker root-mean-square errors less than 2cm, and residual force magnitudes smaller than 2% of peak external force. Finally, we confirmed that AddBiomechanics accurately reproduced joint kinematics and kinetics from synthetic walking data with low marker error and residual loads. We have published the algorithm as an open source cloud service at AddBiomechanics.org, which is available at no cost and asks that users agree to share processed and de-identified data with the community. As of this writing, hundreds of researchers have used the prototype tool to process and share about ten thousand motion files from about one thousand experimental subjects. Reducing the barriers to processing and sharing high-quality human motion biomechanics data will enable more people to use state-of-the-art biomechanical analysis, do so at lower cost, and share larger and more accurate datasets.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA