Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53.681
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Physiol Rev ; 103(3): 1789-1826, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36787480

RESUMO

Solar ultraviolet-B (UV-B) radiation has played a crucial role in the evolution of life on Earth, and potential changes in its levels could affect the health and functionality of humans and the ecosystems. UV exposure presents both risks and benefits to humans. However, optimal UV-B radiation exposure depends on several environmental and physiological factors and cannot be easily determined. The present document provides a review of the current state of knowledge relative to the effects of UV-B radiation on human health. A brief description of the physical mechanisms that control the levels of solar UV-B radiation at the Earth's surface is provided, with special emphasis on the role of ozone and the importance of the Montreal Protocol. A comprehensive review of studies reporting current trends in levels of surface solar UV-B radiation and projections of future levels reveals the dominant role of climatic changes in the long-term variability of UV-B radiation and its impact on the development of melanomas as well as eye disorders. The review provides strong evidence that despite the success of the Montreal Protocol and the expected ozone recovery, the future evolution of the levels of solar UV-B radiation at the Earth's surface is not certain.


Assuntos
Ecossistema , Ozônio , Humanos , Raios Ultravioleta/efeitos adversos , Doses de Radiação
2.
Cell ; 156(3): 603-616, 2014 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-24485463

RESUMO

Glioblastomas (GBMs) are the most common and malignant primary brain tumors and are aggressively treated with surgery, chemotherapy, and radiotherapy. Despite this treatment, recurrence is inevitable and survival has improved minimally over the last 50 years. Recent studies have suggested that GBMs exhibit both heterogeneity and instability of differentiation states and varying sensitivities of these states to radiation. Here, we employed an iterative combined theoretical and experimental strategy that takes into account tumor cellular heterogeneity and dynamically acquired radioresistance to predict the effectiveness of different radiation schedules. Using this model, we identified two delivery schedules predicted to significantly improve efficacy by taking advantage of the dynamic instability of radioresistance. These schedules led to superior survival in mice. Our interdisciplinary approach may also be applicable to other human cancer types treated with radiotherapy and, hence, may lay the foundation for significantly increasing the effectiveness of a mainstay of oncologic therapy. PAPERCLIP:


Assuntos
Neoplasias Encefálicas/radioterapia , Glioblastoma/radioterapia , Doses de Radiação , Animais , Neoplasias Encefálicas/patologia , Glioblastoma/patologia , Humanos , Camundongos , Modelos Biológicos
3.
Radiology ; 311(2): e231741, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771176

RESUMO

Performing CT in children comes with unique challenges such as greater degrees of patient motion, smaller and densely packed anatomy, and potential risks of radiation exposure. The technical advancements of photon-counting detector (PCD) CT enable decreased radiation dose and noise, as well as increased spatial and contrast resolution across all ages, compared with conventional energy-integrating detector CT. It is therefore valuable to review the relevant technical aspects and principles specific to protocol development on the new PCD CT platform to realize the potential benefits for this population. The purpose of this article, based on multi-institutional clinical and research experience from pediatric radiologists and medical physicists, is to provide protocol guidance for use of PCD CT in the imaging of pediatric patients.


Assuntos
Fótons , Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Criança , Lactente , Pediatria/métodos , Pré-Escolar , Guias de Prática Clínica como Assunto
4.
Radiology ; 312(1): e232453, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39078296

RESUMO

Background Contrast-unenhanced abdominal CT is the imaging standard for urinary calculi detection; however, studies comparing photon-counting detector (PCD) CT and energy-integrating detector (EID) CT dose-reduction potentials are lacking. Purpose To compare the radiation dose and image quality of optimized EID CT with those of an experimental PCD CT scan protocol including tin prefiltration in patients suspected of having urinary calculi. Materials and Methods This retrospective single-center study included patients who underwent unenhanced abdominal PCD CT or EID CT for suspected urinary caliculi between February 2022 and March 2023. Signal and noise measurements were performed at three anatomic levels (kidney, psoas, and obturator muscle). Nephrolithiasis and/or urolithiasis presence was independently assessed by three radiologists, and diagnostic confidence was recorded on a five-point scale (1, little to no confidence; 5, complete confidence). Reader agreement was determined by calculating Krippendorff α. Results A total of 507 patients (mean age, 51.7 years ± 17.4 [SD]; 317 male patients) were included (PCD CT group, 229 patients; EID CT group, 278 patients). Readers 1, 2, and 3 detected nephrolithiasis in 129, 127, and 129 patients and 94, 94, and 94 patients, whereas the readers detected urolithiasis in 113, 114, and 114 patients and 152, 153, and 152 patients in the PCD CT and EID CT groups, respectively. Regardless of protocol (PCD CT or EID CT) or calculus localization, near perfect interreader agreement was found (α ≥ 0.99; 95% CI: 0.99, 1). There was no evidence of a difference in reader confidence between PCD CT and EID CT (median confidence, 5; IQR, 5-5; P ≥ .57). The effective doses were 0.79 mSv (IQR, 0.63-0.99 mSv) and 1.39 mSv (IQR, 1.01-1.87 mSv) for PCD CT and EID CT, respectively. Despite the lower radiation exposure, the signal-to-noise ratios at the kidney, psoas, and obturator levels were 30%, 23%, and 17% higher, respectively, in the PCD CT group (P < .001). Conclusion Submillisievert abdominal PCD CT provided high-quality images for the diagnosis of urinary calculi; radiation exposure was reduced by 44% with a higher signal-to-noise ratio than with EID CT and with no evidence of a difference in reader confidence. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Nezami and Malayeri in this issue.


Assuntos
Tomografia Computadorizada por Raios X , Cálculos Urinários , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Cálculos Urinários/diagnóstico por imagem , Doses de Radiação , Adulto , Fótons , Radiografia Abdominal/métodos , Idoso
5.
Radiology ; 311(3): e232677, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38916504

RESUMO

Background CT-derived bronchial parameters have been linked to chronic obstructive pulmonary disease and asthma severity, but little is known about these parameters in healthy individuals. Purpose To investigate the distribution of bronchial parameters at low-dose CT in individuals with healthy lungs from a Dutch general population. Materials and Methods In this prospective study, low-dose chest CT performed between May 2017 and October 2022 were obtained from participants who had completed the second-round assessment of the prospective, longitudinal Imaging in Lifelines study. Participants were aged at least 45 years, and those with abnormal spirometry, self-reported respiratory disease, or signs of lung disease at CT were excluded. Airway lumens and walls were segmented automatically. The square root of the bronchial wall area of a hypothetical airway with an internal perimeter of 10 mm (Pi10), luminal area (LA), wall thickness (WT), and wall area percentage were calculated. Associations between sex, age, height, weight, smoking status, and bronchial parameters were assessed using univariable and multivariable analyses. Results The study sample was composed of 8869 participants with healthy lungs (mean age, 60.9 years ± 10.4 [SD]; 4841 [54.6%] female participants), including 3672 (41.4%) never-smokers and 1197 (13.5%) individuals who currently smoke. Bronchial parameters for male participants were higher than those for female participants (Pi10, slope [ß] range = 3.49-3.66 mm; LA, ß range = 25.40-29.76 mm2; WT, ß range = 0.98-1.03 mm; all P < .001). Increasing age correlated with higher Pi10, LA, and WT (r2 range = 0.06-0.09, 0.02-0.01, and 0.02-0.07, respectively; all P < .001). Never-smoking individuals had the lowest Pi10 followed by formerly smoking and currently smoking individuals (3.62 mm ± 0.13, 3.68 mm ± 0.14, and 3.70 mm ± 0.14, respectively; all P < .001). In multivariable regression models, age, sex, height, weight, and smoking history explained up to 46% of the variation in bronchial parameters. Conclusion In healthy individuals, bronchial parameters differed by sex, height, weight, and smoking history; male sex and increasing age were associated with wider lumens and thicker walls. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Emrich and Varga-Szemes in this issue.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Prospectivos , Pulmão/diagnóstico por imagem , Brônquios/diagnóstico por imagem , Doses de Radiação , Idoso , Países Baixos
6.
Ann Rheum Dis ; 83(6): 807-815, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38490729

RESUMO

OBJECTIVE: To investigate the ability of MRI-based synthetic CT (sCT), low-dose CT (ldCT) and radiography to detect spinal new bone formation (NBF) in patients with axial spondyloarthritis (axSpA). METHODS: Radiography of lumbar and cervical spine, ldCT and sCT of the entire spine were performed in 17 patients with axSpA. sCT was reconstructed using the BoneMRI application (V.1.6, MRIGuidance BV, Utrecht, NL), a quantitative three-dimensional MRI-technique based on a dual-echo gradient sequence and a machine learning processing pipeline that can generate CT-like MR images. Images were anonymised and scored by four readers blinded to other imaging/clinical information, applying the Canada-Denmark NBF assessment system. RESULTS: Mean scores of NBF lesions for the four readers were 188/209/37 for ldCT/sCT/radiography. Most NBF findings were at anterior vertebral corners with means 163 on ldCT, 166 on sCT and 35 on radiography. With ldCT of the entire spine as reference standard, the sensitivity to detect NBF was 0.67/0.13 for sCT/radiography; both with specificities >0.95. For levels that were assessable on radiography (C2-T1 and T12-S1), the sensitivity was 0.61/0.48 for sCT/radiography, specificities >0.90. For facet joints, the sensitivity was 0.46/0.03 for sCT/radiography, specificities >0.94. The mean inter-reader agreements (kappa) for all locations were 0.68/0.58/0.56 for ldCT/sCT/radiography, best for anterior corners. CONCLUSION: With ldCT as reference standard, MRI-based sCT of the spine showed very high specificity and a sensitivity much higher than radiography, despite limited reader training. sCT could become highly valuable for detecting/monitoring structural spine damage in axSpA, not the least in clinical trials.


Assuntos
Espondiloartrite Axial , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Imageamento por Ressonância Magnética/métodos , Feminino , Adulto , Masculino , Tomografia Computadorizada por Raios X/métodos , Espondiloartrite Axial/diagnóstico por imagem , Pessoa de Meia-Idade , Vértebras Lombares/diagnóstico por imagem , Vértebras Cervicais/diagnóstico por imagem , Doses de Radiação , Osteogênese , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/patologia
7.
J Vasc Surg ; 79(4): 954-961, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37931886

RESUMO

OBJECTIVE: Despite the advantages that fenestrated endovascular aortic repair has over open repair, it is accompanied by the consequence of radiation exposure, which can result in long-term complications for both the patient and surgical staff. Fiber Optic RealShape (FORS) technology is a novel advancement that uses emitted light from a fiber optic wire and enables the surgeon to cannulate vessels in real time without live fluoroscopy. This technology has been implemented at select centers to study its effectiveness for cannulation of target vessels and its impact on procedural radiation. METHODS: We collected prospective data on physician-modified endograft (PMEG) cases before and after the introduction of FORS technology. FORS PMEGs were matched with up to three conventional fluoroscopy cases by number of target vessels, inclusion of a bifurcated device below, aneurysm extent, and patient body mass index. The procedural radiation parameters were compared between these cohorts. Within the FORS cohort, we analyzed the rate of successful target vessel cannulation for all cases done with this technology (including cases other than PMEGs), and we compared the radiation between the cannulations using only FORS with those that abandoned FORS for conventional fluoroscopy. RESULTS: Nineteen FORS PMEGs were able to be matched to 45 conventional fluoroscopy cases. Procedures that used FORS technology had significantly reduced total air kerma (527 mGy vs 964 mGy), dose area product (121 Gy∗cm2 vs 186 Gy∗cm2), fluoroscopy dose (72.1 Gy∗cm2 vs 132.5 Gy∗cm2), and fluoroscopy time (45 minutes vs 72 minutes). There was no difference in procedure length, total contrast, or digital subtraction angiography. Within FORS cases, 66% of cannulations were completed using only FORS. Cannulations using only FORS had significant reduction of navigation air kerma (5.0 mGy vs 26.5 mGy), dose area product (1.2 Gy∗cm2 vs 5.1 Gy∗cm2), and fluoroscopy time (0.6 minutes vs 2.3 minutes) compared with cannulations abandoning FORS for conventional fluoroscopy. CONCLUSIONS: This study demonstrates the advantages of FORS for total procedural radiation as well as during individual cannulation tasks. The implementation of FORS for target vessel catheterization has the potential to decrease the total degree of radiation exposure for the patient and surgical staff during complex endovascular aortic surgeries.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Exposição à Radiação , Humanos , Estudos Prospectivos , Aortografia/métodos , Resultado do Tratamento , Tecnologia , Doses de Radiação , Fluoroscopia , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos
8.
J Vasc Surg ; 79(4): 948-953, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38040201

RESUMO

OBJECTIVE: Breast cancer most commonly occurs in the upper outer quadrant (UOQ) chest wall (CW). The effectiveness of routine leaded aprons to protect this region of the body in interventionalists during fluoroscopically guided interventions (FGIs) is unknown. Given the high lifetime attributable risks of prolonged occupational exposure to ionizing radiation and the increasing number of practicing female vascular surgeons and interventionalists, we sought to determine if the use of a leaded arm shield would offer additional protection to the lateral CW and axilla in operators compared with routine leaded aprons. METHODS: Effectiveness of leaded sleeves in attenuating radiation dose to the axilla and UOQ was evaluated in clinical practice and simulated scenarios. In the clinical setting, optically stimulated luminescence nanoDot detectors were placed at the UOQ lateral CW position, both over and under a standard leaded apron vest with and without the addition of an antimony/bismuth Enviro-Lite sleeve on two vascular surgeons performing FGIs. In the simulation, nanoDots were similarly placed on an anthropomorphic phantom positioned to represent a primary operator performing right femoral access. Fluorography was performed on 12-inch-thick acrylic scatter phantom at 80 kVp for an exposure of 3 Gy reference air kerma. Experiments were done with and without the sleeve. Paired Wilcoxon and χ2 tests were performed to identify the statistical significance of radiation attenuation. RESULTS: Operator UOQ CW dose was measured during 61 FGIs: 33 cases (54%) with and 28 cases (46%) without the sleeve. Median procedure reference air kerma and fluoroscopy time was 180 mGy (interquartile range [IQR], 85-447 mGy) and 21 minutes (IQR, 11-39 minutes) when the sleeve was worn vs 100 mGy (IQR, 67-270 mGy) and 11 minutes (IQR, 6.3-25 minutes) without the sleeve. Radiation dose to the operator's UOQ was reduced by 96% (IQR, 85%-96%) when the sleeve was present and by 62% (IQR, 44%-82%; P < .001) without the sleeve. In the simulated setting, the sleeve reduced the radiation dose to the UOQ compared with the apron alone (96% vs 67%; P < .001). CONCLUSIONS: Routine leaded aprons do attenuate the majority of UOQ chest wall radiation dose; however, the addition of a lead-equivalent sleeve further significantly reduces this dose. Because this area of the body has a high incidence of cancer formation, additional protection, especially to female interventionalists, seems prudent. Vascular surgeons should consider using a protective sleeve with their personal protective equipment when performing complex fluoroscopically guided procedures.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Parede Torácica , Humanos , Feminino , Doses de Radiação , Braço , Roupa de Proteção , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Fluoroscopia , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos
9.
J Vasc Surg ; 79(6): 1306-1314.e2, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38368998

RESUMO

OBJECTIVE: Radiation exposure during complex endovascular aortic repair may be associated with tangible adverse effects in patients and operators. This study aimed to identify the steps of highest radiation exposure during fenestrated endovascular aortic repair (FEVAR) and to investigate potential intraoperative factors affecting radiation exposure. METHODS: Prospective data of 31 consecutive patients managed exclusively with four-fenestration endografts between March 1, 2020, and July 1, 2022 were retrospectively analyzed. Leveraging the conformity of the applied technique, every FEVAR operation was considered a combination of six overall stages composed of 28 standardized steps. Intraoperative parameters, including air kerma, dose area product, fluoroscopy time, and number of digital subtraction angiographies (DSAs) and average angulations were collected and analyzed for each step. RESULTS: The mean procedure duration and fluoroscopy time was 140 minutes (standard deviation [SD], 32 minutes), and 40 minutes (SD, 9.1 minutes), respectively. The mean air kerma was 814 mGy (SD, 498 mGy), and the mean dose area product was 66.8 Gy cm2 (SD, 33 Gy cm2). The percentage of air kerma of the entire procedure was distributed throughout the following procedure stages: preparation (13.9%), main body (9.6%), target vessel cannulation (27.8%), stent deployment (29.1%), distal aortoiliac grafting (14.3%), and completion (5.3%). DSAs represented 23.0% of the total air kerma. Target vessel cannulation and stent deployment presented the highest mean lateral angulation (67 and 63 degrees, respectively). Using linear regression, each minute of continuous fluoroscopy added 18.9 mGy of air kerma (95% confidence interval, 17.6-20.2 mGy), and each DSA series added 21.1 mGy of air kerma (95% confidence interval, 17.9-24.3 mGy). Body mass index and lateral angulation were significantly associated with increased air kerma (P < .001). CONCLUSIONS: Cannulation of target vessels and bridging stent deployment are the steps requiring the highest radiation exposure during FEVAR cases. Optimized operator protection during these steps is mandatory.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Doses de Radiação , Exposição à Radiação , Humanos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Exposição à Radiação/prevenção & controle , Exposição à Radiação/efeitos adversos , Estudos Retrospectivos , Masculino , Feminino , Idoso , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Fatores de Tempo , Radiografia Intervencionista/efeitos adversos , Fatores de Risco , Prótese Vascular , Idoso de 80 Anos ou mais , Stents , Resultado do Tratamento , Medição de Risco , Duração da Cirurgia , Aortografia , Pessoa de Meia-Idade , Angiografia Digital , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/efeitos adversos , Fluoroscopia , Correção Endovascular de Aneurisma
10.
Eur J Nucl Med Mol Imaging ; 51(7): 1869-1875, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38407598

RESUMO

PURPOSE: Long axial field-of-view (LAFOV) positron emission tomography (PET) systems allow to image all major organs with one bed position, which is particularly useful for acquiring whole-body dynamic data using short-lived radioisotopes like 82Rb. METHODS: We determined the absorbed dose in target organs of three subjects (29, 40, and 57 years old) using two different methods, i.e., MIRD and voxel dosimetry. The subjects were injected with 407.0 to 419.61 MBq of [82Rb]Cl and were scanned dynamically for 7 min with a LAFOV PET/CT scanner. RESULTS: Using the MIRD formalism and voxel dosimetry, the absorbed dose ranged from 1.84 to 2.78 µGy/MBq (1.57 to 3.92 µGy/MBq for voxel dosimetry) for the heart wall, 2.76 to 5.73 µGy/MBq (3.22 to 5.37 µGy/MBq for voxel dosimetry) for the kidneys, and 0.94 to 1.88 µGy/MBq (0.98 to 1.92 µGy/MBq for voxel dosimetry) for the lungs. The total body effective dose lied between 0.50 and 0.76 µSv/MBq. CONCLUSION: Our study suggests that the radiation dose associated with [82Rb]Cl PET/CT can be assessed by means of dynamic LAFOV PET and that it is lower compared to literature values.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radiometria , Radioisótopos de Rubídio , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Pessoa de Meia-Idade , Adulto , Radiometria/métodos , Masculino , Doses de Radiação , Feminino
11.
Eur J Nucl Med Mol Imaging ; 51(7): 2137-2150, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38286936

RESUMO

AIM: In addition to significant improvements in sensitivity and image quality, the recent introduction of long axial field-of-view (LAFOV) PET/CT scanners has enabled dynamic whole-body imaging for the first time. We aim herein to determine an appropriate acquisition time range for static low-dose [18F]PSMA-1007 PET imaging and to investigate the whole-body pharmacokinetics of [18F]PSMA-1007 by dynamic PET with the LAFOV Biograph Vision Quadra PET/CT in a group of prostate cancer patients. METHODOLOGY: In total, 38 prostate cancer patients were enrolled in the analysis for staging or re-staging purposes. Thirty-four patients underwent dynamic whole-body PET/CT (60 min) followed by static whole-body PET/CT and four patients underwent static whole-body PET/CT only. The activity applied was 2 MBq/kg [18F]PSMA-1007. The static PET images of 10-min duration (PET-10) were reconstructed and further split into 8-min (PET-8), 6-min (PET-6), 5-min (PET-5), 4-min (PET-4), and 2-min (PET-2) duration groups. Comparisons were made between the different reconstructed scan times in terms of lesion detection rate and image quality based on SUV calculations of tumor lesions and the spleen, which served as background. Analysis of the dynamic PET/CT data was based on a two-tissue compartment model using an image-derived input function obtained from the descending aorta. RESULTS: Analysis of lesion detection rate showed no significant differences when reducing PET acquisitions from 10 up to 5 min. In particular, a total of 169 lesions were counted with PET-10, and the corresponding lesion detection rates (95% CI for the 90% quantile of the differences in tumor lesions) for shorter acquisitions were 100% (169/169) for PET-8 (95% CI: 0-0), 98.8% (167/169) for PET-6 (95% CI: 0-1), 95.9% (162/169) for PET-5 (95% CI: 0-3), 91.7% (155/169) for PET-4 (95% CI: 1-2), and 85.2% (144/169) for PET-2 (95% CI: 1-6). With the exception of PET-2, the differences observed between PET-10 and the other shorter acquisition protocols would have no impact on any patient in terms of clinical management. Objective evaluation of PET/CT image quality showed no significant decrease in tumor-to-background ratio (TBR) with shorter acquisition times, despite a gradual decrease in signal-to-noise ratio (SNR) in the spleen. Whole-body quantitative [18F]PSMA-1007 pharmacokinetic analysis acquired with full dynamic PET scanning was feasible in all patients. Two-tissue compartment modeling revealed significantly higher values for the parameter k3 in tumor lesions and parotid gland compared to liver and spleen, reflecting a higher specific tracer binding to the PSMA molecule and internalization rate in these tissues, a finding also supported by the respective time-activity curves. Furthermore, correlation analysis demonstrated a significantly strong positive correlation (r = 0.72) between SUV and k3 in tumor lesions. CONCLUSIONS: In prostate cancer, low-dose (2 MBq/kg) [18F]PSMA-1007 LAFOV PET/CT can reduce static scan time by 50% without significantly compromising lesion detection rate and objective image quality. In addition, dynamic PET can elucidate molecular pathways related to the physiology of [18F]PSMA-1007 in both tumor lesions and normal organs at the whole-body level. These findings unfold many of the potentials of the new LAFOV PET/CT technology in the field of PSMA-based diagnosis and theranostics of prostate cancer.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Imagem Corporal Total , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Idoso , Pessoa de Meia-Idade , Niacinamida/análogos & derivados , Niacinamida/farmacocinética , Oligopeptídeos/farmacocinética , Radioisótopos de Flúor/farmacocinética , Idoso de 80 Anos ou mais , Doses de Radiação , Compostos Radiofarmacêuticos/farmacocinética
12.
BMC Cancer ; 24(1): 437, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594603

RESUMO

BACKGROUND: Soft tissue sarcomas (STS), have significant inter- and intra-tumoral heterogeneity, with poor response to standard neoadjuvant radiotherapy (RT). Achieving a favorable pathologic response (FPR ≥ 95%) from RT is associated with improved patient outcome. Genomic adjusted radiation dose (GARD), a radiation-specific metric that quantifies the expected RT treatment effect as a function of tumor dose and genomics, proposed that STS is significantly underdosed. STS have significant radiomic heterogeneity, where radiomic habitats can delineate regions of intra-tumoral hypoxia and radioresistance. We designed a novel clinical trial, Habitat Escalated Adaptive Therapy (HEAT), utilizing radiomic habitats to identify areas of radioresistance within the tumor and targeting them with GARD-optimized doses, to improve FPR in high-grade STS. METHODS: Phase 2 non-randomized single-arm clinical trial includes non-metastatic, resectable high-grade STS patients. Pre-treatment multiparametric MRIs (mpMRI) delineate three distinct intra-tumoral habitats based on apparent diffusion coefficient (ADC) and dynamic contrast enhanced (DCE) sequences. GARD estimates that simultaneous integrated boost (SIB) doses of 70 and 60 Gy in 25 fractions to the highest and intermediate radioresistant habitats, while the remaining volume receives standard 50 Gy, would lead to a > 3 fold FPR increase to 24%. Pre-treatment CT guided biopsies of each habitat along with clip placement will be performed for pathologic evaluation, future genomic studies, and response assessment. An mpMRI taken between weeks two and three of treatment will be used for biological plan adaptation to account for tumor response, in addition to an mpMRI after the completion of radiotherapy in addition to pathologic response, toxicity, radiomic response, disease control, and survival will be evaluated as secondary endpoints. Furthermore, liquid biopsy will be performed with mpMRI for future ancillary studies. DISCUSSION: This is the first clinical trial to test a novel genomic-based RT dose optimization (GARD) and to utilize radiomic habitats to identify and target radioresistance regions, as a strategy to improve the outcome of RT-treated STS patients. Its success could usher in a new phase in radiation oncology, integrating genomic and radiomic insights into clinical practice and trial designs, and may reveal new radiomic and genomic biomarkers, refining personalized treatment strategies for STS. TRIAL REGISTRATION: NCT05301283. TRIAL STATUS: The trial started recruitment on March 17, 2022.


Assuntos
Temperatura Alta , Sarcoma , Humanos , Radiômica , Sarcoma/diagnóstico por imagem , Sarcoma/genética , Sarcoma/radioterapia , Genômica , Doses de Radiação
13.
BMC Cancer ; 24(1): 548, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689248

RESUMO

PURPOSE: For patients with early-stage cervical cancer without high-risk factors, there is no consensus regarding the optimal postoperative treatment regimen and whether postoperative concurrent radiochemotherapy (CCRT) is superior to radiotherapy (RT) alone. PATIENTS AND METHODS: The medical records of patients with stage I-IIA cervical cancer, who underwent radical surgery and postoperative RT or CCRT between June 2012 and December 2017, were retrospectively reviewed. Patients with any high-risk factors, including positive pelvic lymph node(s), positive resection margin(s), and parametrial invasion, were excluded. Patients with large tumors (≥ 4 cm), deep stromal invasion (≥ 1/2), and lymphovascular space involvement were categorized as the intermediate-risk group. Patients without intermediate-risk factors were categorized as the low-risk group. RESULTS: A total of 403 patients were enrolled and divided into 2 groups according to postoperative treatment: RT alone (n = 105); and CCRT (n = 298). For risk stratification, patients were also divided into 2 groups: intermediate-risk (n = 350); and low-risk (n = 53). The median follow-up was 51.7 months. Patients in the intermediate-risk group and those with multiple intermediate-risk factors were more likely to undergo CCRT. For patients who underwent RT alone or CCRT in the intermediate-risk group, 5-year overall survival (OS) rates were 93.4% and 93.8% (p = 0.741), and 5-year disease-free survival (DFS) rates were 90.6% and 91.4%, respectively (p = 0.733). Similarly, for patients who underwent RT alone or CCRT in the low-risk group, the 5-year OS rates were 100.0% and 93.5% (p = 0.241), and 5-year DFS rates were 94.4% and 93.5%, respectively (p = 0.736). Adjuvant CCRT or RT were not independent risk factors for either OS or DFS. Patients who underwent CCRT appeared to develop a higher proportion of grade ≥ 3 acute hematological toxicities than those in the RT group (44.0% versus 11.4%, respectively; p < 0.001). There was no significant difference in grade ≥ 3 chronic toxicities of the urogenital and gastrointestinal systems between the CCRT and RT groups. CONCLUSION: There was no significant difference in 5-year OS and DFS rates between patients with early-stage cervical cancer without high-risk factors undergoing postoperative CCRT versus RT alone. Patients who underwent CCRT appeared to develop a higher proportion of grade ≥ 3 acute hematological toxicities than those who underwent RT alone.


Assuntos
Quimiorradioterapia , Radioterapia Adjuvante , Neoplasias do Colo do Útero , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/cirurgia , Neoplasias do Colo do Útero/terapia , Humanos , Adulto , Estudos Retrospectivos , Estadiamento de Neoplasias , Histerectomia , Excisão de Linfonodo , Doses de Radiação , Resultado do Tratamento , Taxa de Sobrevida , Pessoa de Meia-Idade , Idoso
14.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488927

RESUMO

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , Fluoroscopia/efeitos adversos , Exposição à Radiação/prevenção & controle , Doses de Radiação
15.
World J Urol ; 42(1): 266, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38676726

RESUMO

PURPOSE: Considering the existing gaps in the literature regarding patient radiation dose (RD) and its associated risks, a systematic review of the literature on RD was conducted, focusing on percutaneous nephrolithotomy (PCNL), extracorporeal shock wave lithotripsy (SWL), and ureteroscopy (URS). METHODS: Two authors conducted a literature search on PubMed, Web of Science, and Google Scholar to identify studies on RD during endourological procedures. Two thousand two hundred sixty-six articles were screened. Sixty-five publications met the inclusion criteria using the PRISMA standards. RESULTS: RD was generally highest for PCNL, reaching levels up to 33 mSv, 28,700 mGycm2, and 430.8 mGy. This was followed by SWL, with RD reaching up to 7.32 mSv, 13,082 mGycm2, and 142 mGy. URS demonstrated lower RD, reaching up to 6.07 mSv, 8920 mGycm2, and 46.99 mGy. Surgeon experience and case load were inversely associated with RD. Strategies such as optimizing fluoroscopy settings, implementing ultrasound (US), and following the ALARA (As Low As Reasonably Achievable) principle minimized RD. CONCLUSIONS: This is the first systematic review analyzing RD, which was generally highest during PCNL, followed by SWL and URS. There is no specific RD limit for these procedures. Implementation of strategies such as optimizing fluoroscopy settings, utilizing US, and adhering to the ALARA principle proved effective in reducing RD. However, further research is needed to explore the factors influencing RD, assess their impact on patient outcomes, and establish procedure-specific reference levels for RD.


Assuntos
Litotripsia , Nefrolitotomia Percutânea , Exposição à Radiação , Ureteroscopia , Humanos , Ureteroscopia/efeitos adversos , Nefrolitotomia Percutânea/efeitos adversos , Nefrolitotomia Percutânea/métodos , Litotripsia/efeitos adversos , Litotripsia/métodos , Doses de Radiação
16.
Eur Radiol ; 34(3): 1605-1613, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37646805

RESUMO

OBJECTIVE: Quantify the relationship between CT acquisition parameters and radiation dose, how often parameters are adjusted in real-world practice, and their degree of contribution to real-world dose distribution. Identify discrepancies between parameters that are impactful in theory and impactful in practice. METHODS: This study analyses 1.3 million consecutive adult routine abdomen exams performed between November 2015 and Jan 2021 included in the University of California, San Francisco International CT Dose Registry of 155 institutions. We calculated geometric standard deviation (gSD) for five parameters (kV, mAs, spiral pitch, number of phases, scan length) to assess variation in practice. A Gaussian mixed regression model was performed to predict the radiation dose-length product (DLP) using the parameters. Three conceptualizations of "impact" were computed for each parameter. To reflect the theoretical impact, we predict the increase in DLP per 10% (and 15%) increase in the parameter. To reflect the real-world practical impact, we predict the increase in DLP per gSD increase in the parameter. RESULTS: Among studied examinations, mAs, number of phases, and scan length were frequently manipulated (gSD 1.52-1.70); kV was rarely manipulated (gSD 1.07). Theoretically, kV is the most impactful parameter (29% increase in DLP per 10% increase in kV, versus 5-9% increase for other parameters). In real-world practice, kV is less impactful; for each gSD increase in kV, the DLP increases by 20%, versus 22-69% for other parameters. CONCLUSION: Despite the potential impact of kV on radiation dose, this parameter is rarely manipulated in common practice and this potential remains untapped. CLINICAL RELEVANCE STATEMENT: CT beam energy (kV) modulation has the potential to strongly reduce radiation over-dosage to the patient, theoretically more so than similar degrees of modulation in other CT acquisition parameters. Despite this, beam energy modulation rarely occurs in practice, leaving its potential untapped. KEY POINTS: • The relationship between CT acquisition parameter selection and radiation dose roughly coincided with established theoretical understanding. • CT acquisition parameters differ from each other in frequency and magnitude of manipulation, with beam energy (kV) being rarely manipulated. • Beam energy (kV) has the potential to substantially impact radiation dose, but because it is rarely manipulated, it is the least impactful CT acquisition parameter affecting radiation dose in practice.


Assuntos
Tomografia Computadorizada por Raios X , Adulto , Humanos , Doses de Radiação
17.
Eur Radiol ; 34(4): 2394-2404, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37735276

RESUMO

OBJECTIVE: To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT. METHODS: We retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation. Lastly, we modeled the total population dose if all protocols with mean size-adjusted DLP above 433 or 645 mGy-cm were reduced to these thresholds. RESULTS: A total of 748,846 CTs were performed using 1033 unique protocols. When sorted by patient size, patients with larger abdominal diameters had increased dose and effective mAs (milliampere seconds), even after adjusting for patient size. When sorted by size-adjusted dose, patients in the highest versus the lowest decile in size-adjusted DLP received 6.4 times the average dose (1680 vs 265 mGy-cm) even though diameter was no different (312 vs 309 mm). Effective mAs was 2.1-fold higher, unadjusted CTDIvol 2.9-fold, and phase 2.5-fold for patients in the highest versus lowest size-adjusted DLP decile. There was virtually no change in kV (kilovolt). Automatic exposure control was widely used to modulate mAs, whereas kV modulation was rare. Phase was the strongest driver of between-protocols variation. Broad adoption of optimized protocols could result in total population dose reductions of 18.6-40%. CONCLUSION: There are large variations in radiation doses for routine abdomen CT unrelated to patient size. Modification of kV and single-phase scanning could result in substantial dose reduction. CLINICAL RELEVANCE: Radiation dose-optimization techniques for routine abdomen CT are routinely under-utilized leading to higher doses than needed. Greater modification of technical parameters and number of phases could result in substantial reduction in radiation exposure to patients. KEY POINTS: • Based on an analysis of 748,846 routine abdomen CT scans in adults, radiation doses varied tremendously across patients of the same size and optimization techniques were routinely under-utilized. • The difference in observed dose was due to variation in technical parameters and phase count. Automatic exposure control was commonly used to modify effective mAs, whereas kV was rarely adjusted for patient size. Routine abdomen CT should be performed using a single phase, yet multi-phase was common. • kV modulation by patient size and restriction to a single phase for routine abdomen indications could result in substantial reduction in radiation doses using well-established dose optimization approaches.


Assuntos
Exposição à Radiação , Tomografia Computadorizada por Raios X , Adulto , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Abdome
18.
Eur Radiol ; 34(1): 411-421, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37552254

RESUMO

OBJECTIVES: Cardiac computed tomography (CT) is essential in diagnosing coronary heart disease. However, a disadvantage is the associated radiation exposure to the patient which depends in part on the scan range. This study aimed to develop a deep neural network to optimize the delimitation of scan ranges in CT localizers to reduce the radiation dose. METHODS: On a retrospective training cohort of 1507 CT localizers randomly selected from calcium scoring and angiography scans and acquired between 2010 and 2017, optimized scan ranges were delimited by two radiologists in consensus. A neural network was trained to reproduce the scan ranges and was tested on two randomly selected and independent validation cohorts: an internal cohort of 233 CT localizers (January 2018-June 2020) and an external cohort from a nearby hospital of 298 CT localizers (July 2020-December 2020). Localizers where a bypass surgery was visible were excluded. The effective radiation dose to the patient was simulated using a Monte Carlo simulation. Scan ranges of radiographers, radiologists, and the network were compared using an equivalence test; likewise, the reduction in effective dose was tested using a superior test. RESULTS: The network replicated the radiologists' scan ranges with a Dice score of 96.5 ± 0.02 (p < 0.001, indicating equivalence). The generated scan ranges resulted in an effective dose reduction of 10.0% (p = 0.002) in the internal cohort and 12.6% (p < 0.001) in the external cohort compared to the scan ranges delimited by radiographers in clinical routine. CONCLUSIONS: Automatic delimitation of the scan range can result in a radiation dose reduction to the patient. CLINICAL RELEVANCE STATEMENT: Fully automated delimitation of the scan range using a deep neural network enables a significant reduction in radiation exposure during CT coronary angiography compared to manual examination planning. It can also reduce the workload of the radiographers. KEY POINTS: • Scan range delimitation for coronary computed tomography angiography could be performed with high accuracy by a deep neural network. • Automated scan ranges showed a high agreement of 96.5% with the scan ranges of radiologists. • Using a Monte Carlo simulation, automated scan ranges reduced the effective dose to the patient by up to 12.6% (0.9 mSv) compared to the scan ranges of radiographers in clinical routine.


Assuntos
Aprendizado Profundo , Exposição à Radiação , Humanos , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Estudos Retrospectivos , Exposição à Radiação/prevenção & controle
19.
Eur Radiol ; 34(3): 1659-1666, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37672054

RESUMO

OBJECTIVE: To report the results of a dose survey conducted across 31 provinces in mainland China from 2017 to 2018 and to analyse the dose level to determine the national diagnostic reference levels (DRLs) for paediatric CT procedures. METHODS: At least ten patients for each age group (0- < 1, 1- < 5, 5- < 10, 10- < 15 years) and each procedure (head, chest and abdomen) for each CT scanner were selected from four to eight hospitals in each province. The dose information (CTDIvol and DLP) was collected from the HIS or RIS-PACS systems. The median values in each CT scanner were considered the representative dose values for the paediatric patients in CT scanning. The national DRLs were estimated based on the 75th percentile distribution of the median values. RESULTS: A total of 24,395 patients and 319 CT scanners were investigated across 262 hospitals. For paediatric CT scanning in 4 different age groups, the median (P50) and the 75th percentile (P75) of CTDIvol and DLP for each scanning procedure were calculated and reported. National DRLs were then proposed for each procedure and age group. CONCLUSION: The dose level of CT scanning for children in mainland China was reported for the first time. The DRLs for paediatric CT in the present study are similar to those in some Asian countries but higher than those in European countries. CLINICAL RELEVANCE STATEMENT: The paediatric CT is an extensively used tool in diagnosing paediatric disease; however, children are more sensitive to radiation. Establishing the diagnostic reference level of paediatric CT examination is necessary to reduce the dose of CT in children and promote the optimisation of medical exposure. KEY POINTS: • The DRLs for 3 paediatric CT procedures (head, chest and abdomen) and 4 age groups (0- < 1, 1- < 5, 5- < 10, 10- < 15 years) were proposed in mainland China first time. • The examination parameter and dose for children need to be further optimised in China, especially to lower the tube voltage in paediatric CT.


Assuntos
Tórax , Tomografia Computadorizada por Raios X , Criança , Humanos , Adolescente , Doses de Radiação , Valores de Referência , Tomografia Computadorizada por Raios X/métodos , China/epidemiologia
20.
Eur Radiol ; 34(4): 2480-2486, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37707547

RESUMO

OBJECTIVES: The aim of the patient out-of-plane shield is to reduce the patient radiation dose. Its effect on tube current modulation was evaluated with the out-of-plane shield visible in the localizer but absent in the scan range in chest CT with different CT scanners. METHODS: An anthropomorphic phantom was scanned with six different CT scanners from three different vendors. The chest was first scanned without any shielding, and then with the out-of-plane shield within the localizer but outside the imaged volume. All pitch values of each scanner were used. The tube current values with and without the out-of-plane shield were collected and used to evaluate the effect of overscanning and tube current modulation (TCM) on patient radiation dose. RESULTS: The highest increase in cumulative mA was 217%, when the pitch was 1.531. The tube current value increased already 8.9 cm before the end of the scanned anatomy and the difference between the tube current of the last slices (with and without the out-of-plane shield in the localizer) was 976%. CONCLUSION: Applying an out-of-plane shield outside the scanned volume but visible in the localizer images may increase the patient dose considerably if the scanner's TCM function is based only on localizer images. CLINICAL RELEVANCE STATEMENT: The use of an out-of-plane shield in CT may strongly increase the tube current modulation and thus provide the patient with a higher radiation dose. KEY POINTS: • Applying an out-of-plane shield outside the scanned volume but visible in the localizer images may increase patient radiation dose considerably. • The effect is visible with scanners that use solely localizer-based tube current modulation. • Features like overscanning may be difficult for the user to notice when planning the scanning, and yet they may affect tube current modulation and through it to patient dose.


Assuntos
Tórax , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA