Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Nephrology (Carlton) ; 25(8): 634-643, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31765028

RESUMO

AIM: Secondary hyperparathyroidism (SHPT), a complication of haemodialysis, is commonly treated with calcimimetics. The impact of dialysates containing different calcium (Ca) concentrations on clinical efficacy of calcimimetics are unclear. We examined whether dialysate Ca concentrations influence the efficacy and dosing of etelcalcetide with concomitant drugs. METHODS: We performed post hoc analyses of a 52-week, open-label, multicentre study of etelcalcetide in Japanese SHPT patients to determine whether dialysate Ca influences the therapeutic effects of etelcalcetide with concomitant drugs. We evaluated the differences in serum intact parathyroid hormone (iPTH), corrected Ca (cCa) and phosphate levels among three dialysate Ca concentration groups (2.5, 2.75 or 3.0 mEq/L Ca). Tartrate-resistant acid phosphatase 5b (TRACP-5b) and bone alkaline phosphatase (BAP) levels were also compared. Since the dialysate Ca concentration may influence dose adjustment, we assessed the etelcalcetide and concomitant drug doses. RESULTS: There were no clinically meaningful differences in iPTH, cCa and phosphate levels among the 2.5, 2.75 and 3.0 mEq/L groups (n = 34, 64 and 35, respectively) over 52 weeks. At Week 52, more than 82%, 71% and 67% of patients had iPTH, cCa and phosphate levels within target ranges (60-240 pg/mL, 8.4-10.0 mg/dL and 3.5-6.0 mg/dL, respectively) across the three groups. TRACP-5b and BAP levels decreased by Week 52 regardless of dialysate Ca. Changes in etelcalcetide and concomitant drug doses were generally similar in each group. CONCLUSION: The efficacy and dosing of etelcalcetide with concomitant drugs were essentially unaffected by the dialysate Ca concentration. Patients showed improvements in bone hypermetabolism during treatment.


Assuntos
Calcificação Fisiológica/efeitos dos fármacos , Cálcio , Soluções para Hemodiálise , Hiperparatireoidismo Secundário , Peptídeos/administração & dosagem , Diálise Renal , Calcimiméticos/administração & dosagem , Cálcio/análise , Cálcio/sangue , Cálcio/química , Relação Dose-Resposta a Droga , Feminino , Soluções para Hemodiálise/análise , Soluções para Hemodiálise/química , Humanos , Hiperparatireoidismo Secundário/sangue , Hiperparatireoidismo Secundário/etiologia , Hiperparatireoidismo Secundário/prevenção & controle , Japão/epidemiologia , Falência Renal Crônica/epidemiologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Glândulas Paratireoides/efeitos dos fármacos , Hormônio Paratireóideo/sangue , Fosfatos/sangue , Diálise Renal/efeitos adversos , Diálise Renal/métodos
2.
Kidney Int ; 95(2): 296-309, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30665570

RESUMO

Space medicine and new technology such as magnetic resonance imaging of tissue sodium stores (23NaMRI) have changed our understanding of human sodium homeostasis and pathophysiology. It has become evident that body sodium comprises 3 main components. Two compartments have been traditionally recognized, namely one that is circulating and systemically active via its osmotic action, and one slowly exchangeable pool located in the bones. The third, recently described pool represents sodium stored in skin and muscle interstitium, and it is implicated in cell and biologic activities via local hypertonicity and sodium clearance mechanisms. This in-depth review provides a comprehensive view on the pathophysiology and existing knowledge gaps of systemic hemodynamic and tissue sodium accumulation in dialysis patients. Furthermore, we discuss how the combination of novel technologies to quantitate tissue salt accumulation (e.g., 23NaMRI) with devices to facilitate the precise attainment of a prescribed hemodialytic sodium mass balance (e.g., sodium and water balancing modules) will improve our therapeutic approach to sodium management in dialysis patients. While prospective studies are required, we think that these new diagnostic and sodium balancing tools will enhance our ability to pursue more personalized therapeutic interventions on sodium and water management, with the eventual goal of improving dialysis patient outcomes.


Assuntos
Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Sódio/metabolismo , Água/metabolismo , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/metabolismo , Soluções para Hemodiálise/análise , Humanos , Falência Renal Crônica/metabolismo , Falência Renal Crônica/fisiopatologia , Imageamento por Ressonância Magnética , Músculos/diagnóstico por imagem , Músculos/metabolismo , Pele/diagnóstico por imagem , Pele/metabolismo , Sódio/análise , Cloreto de Sódio na Dieta/administração & dosagem , Cloreto de Sódio na Dieta/efeitos adversos , Resultado do Tratamento , Equilíbrio Hidroeletrolítico
3.
J Sep Sci ; 40(10): 2246-2252, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28323381

RESUMO

The inclusion of a polyamidoamine dendrimer in a silica sol-gel yielded a solid nanosorbent that was used for the preconcentration, extraction, and determination of citalopram in hospital waste water, hemodialysis solution, and some drinking water. The method was developed by applying a novel nanosorbent for the solid-phase microextraction of citalopram, containing a silica sol-gel reinforced by polyamidoamine second-generation dendrimer, which was protected by a polypropylene hollow fiber. Plackett-Burman design and central composite design were utilized to evaluate the significance of several factors on the extraction efficiency. The adsorption mechanism and thermodynamic and kinetic aspects were studied. The adsorption process was exothermic and well fitted to the Bangham equation kinetic model. Under optimal conditions, the presented method was liner in the range of 0.05-100 µg/mL. The limits of detection of quantification of citalopram were 0.0095 and 0.031 µg m/L, respectively.


Assuntos
Citalopram/isolamento & purificação , Dendrímeros , Microextração em Fase Sólida , Adsorção , Água Potável/análise , Soluções para Hemodiálise/análise , Águas Residuárias/análise
4.
Kidney Int ; 87(2): 434-41, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25100048

RESUMO

We have previously reported that sodium is stored in skin and muscle. The amounts stored in hemodialysis (HD) patients are unknown. We determined whether (23)Na magnetic resonance imaging (sodium-MRI) allows assessment of tissue sodium and its removal in 24 HD patients and 27 age-matched healthy controls. We also studied 20 HD patients before and shortly after HD with a batch dialysis system with direct measurement of sodium in dialysate and ultrafiltrate. Age was associated with higher tissue sodium content in controls. This increase was paralleled by an age-dependent decrease of circulating levels of vascular endothelial growth factor-C (VEGF-C). Older (>60 years) HD patients showed increased sodium and water in skin and muscle and lower VEGF-C levels compared with age-matched controls. After HD, patients with low VEGF-C levels had significantly higher skin sodium content compared with patients with high VEGF-C levels (low VEGF-C: 2.3 ng/ml and skin sodium: 24.3 mmol/l; high VEGF-C: 4.1 ng/ml and skin sodium: 18.2 mmol/l). Thus, sodium-MRI quantitatively detects sodium stored in skin and muscle in humans and allows studying sodium storage reduction in ESRD patients. Age and VEGF-C-related local tissue-specific clearance mechanisms may determine the efficacy of tissue sodium removal with HD. Prospective trials on the relationship between tissue sodium content and hard end points could provide new insights into sodium homeostasis, and clarify whether increased sodium storage is a cardiovascular risk factor.


Assuntos
Diálise Renal , Sódio/isolamento & purificação , Sódio/metabolismo , Adulto , Fatores Etários , Idoso , Estudos de Casos e Controles , Feminino , Soluções para Hemodiálise/análise , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/metabolismo , Falência Renal Crônica/terapia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Distribuição Tecidual , Fator C de Crescimento do Endotélio Vascular/sangue
5.
Am J Kidney Dis ; 61(6): 957-65, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23415416

RESUMO

BACKGROUND: Fluid overload is the main determinant of hypertension and left ventricular hypertrophy in hemodialysis patients. However, assessment of fluid overload can be difficult in clinical practice. We investigated whether objective measurement of fluid overload with bioimpedance spectroscopy is helpful in optimizing fluid status. STUDY DESIGN: Prospective, randomized, and controlled study. SETTING & PARTICIPANTS: 156 hemodialysis patients from 2 centers were randomly assigned to 2 groups. INTERVENTION: Dry weight was assessed by routine clinical practice and fluid overload was assessed by bioimpedance spectroscopy in both groups. In the intervention group (n = 78), fluid overload information was provided to treating physicians and used to adjust fluid removal during dialysis. In the control group (n = 78), fluid overload information was not provided to treating physicians and fluid removal during dialysis was adjusted according to usual clinical practice. OUTCOMES: The primary outcome was regression of left ventricular mass index during a 1-year follow-up. Improvement in blood pressure and left atrial volume were the main secondary outcomes. Changes in arterial stiffness parameters were additional outcomes. MEASUREMENTS: Fluid overload was assessed twice monthly in the intervention group and every 3 months in the control group before the mid- or end-week hemodialysis session. Echocardiography, 48-hour ambulatory blood pressure measurement, and pulse wave analysis were performed at baseline and 12 months. RESULTS: Baseline fluid overload parameters in the intervention and control groups were 1.45 ± 1.11 (SD) and 1.44 ± 1.12 L, respectively (P = 0.7). Time-averaged fluid overload values significantly decreased in the intervention group (mean difference, -0.5 ± 0.8 L), but not in the control group (mean difference, 0.1 ± 1.2 L), and the mean difference between groups was -0.5 L (95% CI, -0.8 to -0.2; P = 0.001). Left ventricular mass index regressed from 131 ± 36 to 116 ± 29 g/m(2) (P < 0.001) in the intervention group, but not in the control group (121 ± 35 to 120 ± 30 g/m(2); P = 0.9); mean difference between groups was -10.2 g/m(2) (95% CI, -19.2 to -1.17 g/m(2); P = 0.04). In addition, values for left atrial volume index, blood pressure, and arterial stiffness parameters decreased in the intervention group, but not in the control group. LIMITATIONS: Ambulatory blood pressure data were not available for all patients. CONCLUSIONS: Assessment of fluid overload with bioimpedance spectroscopy provides better management of fluid status, leading to regression of left ventricular mass index, decrease in blood pressure, and improvement in arterial stiffness.


Assuntos
Água Corporal , Soluções para Hemodiálise/análise , Hipertensão/etiologia , Hipertrofia Ventricular Esquerda/etiologia , Diálise Renal/efeitos adversos , Desequilíbrio Hidroeletrolítico/diagnóstico , Adulto , Espectroscopia Dielétrica , Feminino , Soluções para Hemodiálise/administração & dosagem , Humanos , Hipertensão/terapia , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Ultrassonografia , Rigidez Vascular , Desequilíbrio Hidroeletrolítico/etiologia
6.
Blood Purif ; 35(1-3): 112-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23343555

RESUMO

BACKGROUND/AIMS: Previous studies have suggested that online hemodiafiltration (OL-HDF) fluid can be used as dialysate for continuous renal replacement therapies, and thus HDF costs can be reduced. The aims of this study were to determine the purity of OL-HDF fluid and to verify the stability of the electrolyte composition and acid-base balance during its storage. METHODS: OL-HDF fluid was collected in 70 individual bags and stored for up to 7 days. The following tests were performed daily in 10 bags: natural visible precipitation (macrocrystallization), sample collection for chemical analysis and fluid culture, limulus amebocyte lysate endotoxin test, standard culture of NALGENE® filters after passing of the fluid, and molecular analysis of bacterial DNA. RESULTS: The values of pH and pCO(2) showed a significant change starting at 24 h (p < 0.001); after 72 h, their values were beyond the measurable range. Coefficient of variation for pCO(2) was as high as 25.7%. Electrolyte composition (Na(+), K(+), Cl(-), Ca(2+) and glucose) showed a statistically significant difference over time (p < 0.05); however, their coefficients of variation were low (1.7, 1.4, 0.6, 2.3 and 0.9%, respectively), which might not be considered clinically significant. Negative results were obtained at all points by fluid and filter cultures, endotoxin test and molecular analysis. No macrocrystallization was observed at any time point. CONCLUSIONS: We demonstrate the microbiological purity of OL-HDF fluid stored for up to 7 days. The electrolyte composition was stable, except for a relevant change in pCO(2) and consequently in pH (first noted at 24 h), emphasizing the need to reassess the acid-base balance in multilayer plastic bags in future studies.


Assuntos
Equilíbrio Ácido-Base , Hemodiafiltração/normas , Soluções para Hemodiálise/análise , Soluções para Hemodiálise/normas , Eletrólitos/análise , Endotoxinas/análise , Hemodiafiltração/instrumentação , Soluções para Hemodiálise/química , Humanos , Concentração de Íons de Hidrogênio , Assistência de Longa Duração , Controle de Qualidade
7.
Blood Purif ; 35(1-3): 133-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23343558

RESUMO

BACKGROUND/AIM: Citrate anticoagulation in hemodialysis (HD) is increasingly drawing attention in the nephrology community. One of the major deterrents to a more widespread use are the monitoring requirements for fear of systemic calcium derangements. Means of accurately predicting systemic ionized calcium (iCa) may help to overcome this challenge. We have previously presented a mathematical model of regional citrate anticoagulation (RCA) to address this need. Here, we present a refined model and show results in an independent validation cohort of maintenance HD patients on Citrasate®, a calcium- and citrate-containing dialysate. METHODS: A hybrid RCA model was developed, comprising the previously published 'native' RCA model and a statistical correction based on levels of alkaline phosphatase as a marker of bone turnover. The model was validated in 120 patients on Citrasate, a dialysate containing 0.8 mmol/l citrate and 1.125 mmol/l calcium. Systemic iCa was measured at the beginning and end of one HD treatment in each subject. Serum iCa predictions were compared between our previously published model and the new hybrid model. RESULTS: On average, the hybrid model predicted end-HD systemic iCa with an error (predicted - measured) of 0.028 mmol/l, compared to -0.051 mmol/l with the previously published model. There were only 4 subjects out of the 120 analyzed in whom the prediction error was <-0.1 mmol/l, and only 6 in whom the error was >+0.1 mmol/l (max: +0.13 mmol/l). CONCLUSION: This study demonstrates that the novel hybrid model is an improvement over the previously published model and that it is capable of predicting end-dialysis systemic iCa levels with improved accuracy and precision even in a citrate dialysis setting which was much different from the original derivation cohort.


Assuntos
Anticoagulantes/química , Cálcio/sangue , Citratos/sangue , Soluções para Hemodiálise/análise , Falência Renal Crônica/sangue , Diálise Renal , Idoso , Bicarbonatos/sangue , Coagulação Sanguínea , Estudos de Coortes , Feminino , Soluções para Hemodiálise/química , Humanos , Falência Renal Crônica/patologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Valor Preditivo dos Testes
8.
Kidney Int ; 79(2): 147-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21191388

RESUMO

Sudden cardiac arrest (SCA) is a leading cause of cardiac-associated mortality in dialysis patients. Risk factors unique to hemodialysis patients include abnormal electrolytes, large-volume ultrafiltration, and prior history of cardiac disease. Few randomized controlled trials of standard cardiac interventions have been completed in dialysis patients. Observational studies suggest that modification of the dialysis prescription may be one place to intervene. Prospective research is needed to determine mechanisms of SCA in hemodialysis patients.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Diálise Renal/efeitos adversos , Morte Súbita Cardíaca/etiologia , Soluções para Hemodiálise/análise , Humanos , Potássio/análise , Potássio/sangue , Fatores de Risco , Resultado do Tratamento
9.
Kidney Int ; 79(2): 218-27, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20811332

RESUMO

Sudden cardiac arrest is the most common cause of death among patients with end-stage kidney disease (ESKD) maintained on hemodialysis. Here we sought to identify dialysis-related factors associated with this increased risk in a case-control study encompassing 43,200 patients dialyzed in outpatient clinics of a large organization. Within this group, we compared the clinical and dialysis-specific data of 502 patients who experienced a sudden cardiac arrest with 1632 age- and dialysis-vintage-matched controls. There were 4.5 sudden cardiac arrest events per 100,000 dialysis treatments during the 3-year study period. These patients were significantly more likely to have been exposed to low potassium dialysate of less than 2 meq/l. These differences could not be explained by predialysis serum potassium levels. There was no evidence for a beneficial effect of low potassium dialysate even among those with higher predialysis serum potassium levels. Other factors strongly associated with sudden cardiac arrest by multivariable analysis included increased ultrafiltration volumes, exposure to low calcium dialysate, and predialysis serum creatinine levels. These relationships persisted after adjustment for covariates, but traditional risk factors such as history of coronary heart disease and congestive heart failure were not significantly influential. Hence, our study suggests that modifications of the hemodialysis prescription may improve the risk of sudden cardiac arrest in patients with ESKD.


Assuntos
Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Diálise Renal/efeitos adversos , Idoso , Instituições de Assistência Ambulatorial , Estudos de Casos e Controles , Feminino , Soluções para Hemodiálise/análise , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Potássio/análise , Potássio/sangue , Fatores de Risco
10.
Blood Purif ; 32(2): 112-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21447946

RESUMO

BACKGROUND: In Thailand, dialysate endotoxin contamination levels vary from less than 0.001 to 2.0 EU/ml. This difference has prompted an investigation on the production of proinflammatory cytokines and counter-inflammatory mediators of peripheral blood mononuclear cells (PBMCs) after high-flux dialysis. METHODS: Patients from four hemodialysis (HD) centers who met the inclusion/exclusion criteria were enrolled into the study. PBMCs were isolated by Ficoll density gradient centrifugation and cultured. Supernatants were tested for interleukin 6 (IL-6), IL-1ß and IL-1 receptor antagonist (IL-1Ra) concentration by ELISA. RESULTS: HD centers 1, 2, 3 and 4 had mean dialysate endotoxin contamination levels of 0.001, 0.026, 0.558 and 1.960 EU/ml, respectively. HD center 4 had the highest levels of IL-6 (1,052.3 ± 240.7 pg/10(6) PBMCs), IL-1ß (1,297.1 ± 334.6 pg/10(6) PBMCs) and IL-1Ra (2,713.4 ± 1,255.3 pg/10(6) PBMCs). There were no significant differences in cytokine production between HD centers 1 and 2. CONCLUSION: Our study showed that ultrapure dialysate can minimize the risk of stimulating inflammatory cells. Ultrapure dialysate may prevent or delay endotoxin exposure-related complications.


Assuntos
Endotoxinas/farmacologia , Soluções para Hemodiálise/farmacologia , Falência Renal Crônica/terapia , Leucócitos Mononucleares/efeitos dos fármacos , Ativação Linfocitária/efeitos dos fármacos , Diálise Renal , Adulto , Idoso , Endotoxinas/imunologia , Contaminação de Equipamentos/prevenção & controle , Feminino , Soluções para Hemodiálise/análise , Humanos , Proteína Antagonista do Receptor de Interleucina 1/análise , Proteína Antagonista do Receptor de Interleucina 1/biossíntese , Interleucina-1beta/análise , Interleucina-1beta/biossíntese , Interleucina-6/análise , Interleucina-6/biossíntese , Falência Renal Crônica/fisiopatologia , Leucócitos Mononucleares/imunologia , Masculino , Pessoa de Meia-Idade , Tailândia
11.
Toxins (Basel) ; 13(4)2021 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-33807387

RESUMO

Optical monitoring of spent dialysate has been used to estimate the removal of water-soluble low molecular weight as well as protein-bound uremic toxins from the blood of end stage kidney disease (ESKD) patients. The aim of this work was to develop an optical method to estimate the removal of ß2-microglobulin (ß2M), a marker of middle molecule (MM) uremic toxins, during hemodialysis (HD) treatment. Ultraviolet (UV) and fluorescence spectra of dialysate samples were recorded from 88 dialysis sessions of 22 ESKD patients, receiving four different settings of dialysis treatments. Stepwise regression was used to obtain the best model for the assessment of ß2M concentration in the spent dialysate. The correlation coefficient 0.958 and an accuracy of 0.000 ± 0.304 mg/L was achieved between laboratory and optically estimated ß2M concentrations in spent dialysate for the entire cohort. Optically and laboratory estimated reduction ratio (RR) and total removed solute (TRS) of ß2M were not statistically different (p > 0.35). Dialytic elimination of MM uremic toxin ß2M can be followed optically during dialysis treatment of ESKD patients. The main contributors to the optical signal of the MM fraction in the spent dialysate were provisionally identified as tryptophan (Trp) in small peptides and proteins, and advanced glycation end-products.


Assuntos
Soluções para Hemodiálise/análise , Falência Renal Crônica/terapia , Diálise Renal , Toxinas Biológicas/sangue , Uremia/terapia , Microglobulina beta-2/sangue , Adulto , Idoso , Biomarcadores/sangue , Feminino , Produtos Finais de Glicação Avançada/sangue , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Ligação Proteica , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta , Resultado do Tratamento , Triptofano/sangue , Uremia/sangue , Uremia/diagnóstico
12.
Nephrol Dial Transplant ; 25(3): 873-9, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19854847

RESUMO

BACKGROUND: Urea kinetic modelling-based methods are widely used to assess dialysis efficacy. However, they require blood sampling and are susceptible to a number of errors, mainly from the calculated parameters (particularly V). Spent dialysate determinations have been used and have been shown to be reliable and simple to use. In this study, we associated dialysate-based and clearance determinations along with Kt/V to estimate blood urea levels. METHODS: Urea kinetic modelling, continuous sampling of spent dialysate and ionic dialysance were determined in 18 stable dialysis patients during 126 dialysis sessions. Mean blood urea levels were estimated as follows: mean urea level = spent dialysate - urea mass/(dialysance T). Blood urea levels before and after dialysis were calculated based on the same determinations and extended formulae. RESULTS: Estimated mean urea level was significantly correlated with measured mean blood urea level (R(2) = 0.957; P < 0.0001), and Bland and Altman analysis showed significant agreement between estimated and measured levels. Estimated and measured blood urea levels were also correlated before and after dialysis (R(2) = 0.972 , P < 0.0001 and R(2) = 0.903 , P < 0.0001, respectively), with good agreement for both blood urea before and after dialysis and their respective estimates. CONCLUSIONS: Blood urea levels may be reliably estimated from the total mass of urea removed in the dialysate and the dialysance measured during dialysis. Coupling both measurements allows a precise monitoring of dialysis efficacy and a specific evaluation of the patient's urea metabolism status. Technical dysfunctions and patient variations may be easily identified using this approach without blood sampling.


Assuntos
Soluções para Hemodiálise/análise , Nefropatias/terapia , Modelos Biológicos , Ureia/sangue , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Humanos , Nefropatias/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
PLoS One ; 15(5): e0233331, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32469929

RESUMO

Dialysis urea removal metrics may not translate into proportional removal efficiency of non-urea solutes. We show that the Kt factor (plasma volume totally cleared of any solutes) differentiates removal efficiency of non-urea solutes in different technologies, and can easily be calculated by instant blood-dialysate collections. We performed mass balances of urea, creatinine, phosphorus and beta2-microglobulin by whole dialysate collection in 4 low-flux and 3 high-flux hemodialysis, 2 high-volume post-hemodiafiltration and 7 short-daily dialysis with the NxStage-One system. Instant dialysate/blood determinations were also performed at different times, and Kt was calculated as the product of the D/P ratio by volume of delivered dialysate plus UF. There were significant differences in single session and weekly Kt (whole dialysate and instant calculations) between methodologies, most notably for creatinine, phosphorus and beta2-microglobulin. Urea Kt messured in balance studies was almost equal to that derived from the usual plasma kinetic model-based Daugirdas' equation (eKt/V) and independent V calculation, indicating full correspondence. Non-urea solute Kt as a fraction of urea Kt (i.e. fractional removal relative to urea) showed significant differences between technologies, indicating non-proportional removal of non-urea solutes and urea. Instant Kt was higher than that in full balances, accounting for concentration disequilibrium between arterial and systemic blood, but measured and calculated quantitative solute removal were equal, as were qualitative Kt comparisons between technologies. Thus, we show that urea metrics may not reliably express removal efficiency of non-urea solutes, as indicated by Kt. Kt can easily be measured without whole dialysate collection, allowing to expand the metrics of dialytic efficiency to almost any non-urea solute removed by dialysis.


Assuntos
Algoritmos , Hemodiafiltração/métodos , Soluções para Hemodiálise/análise , Monitorização Fisiológica/métodos , Diálise Renal/métodos , Ureia/sangue , Humanos , Cinética , Monitorização Fisiológica/instrumentação
14.
PLoS One ; 15(7): e0235135, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32628733

RESUMO

BACKGROUND: In patients on hemodialysis (HD), the various chemical elements in the dialysate may influence survival rates. In particular, calcium modifies mineral and bone metabolism and the vascular calcification rate. We studied the influence of the dialysate calcium concentration and the treatments prescribed for mineral bone disease (MBD) on survival. METHODS: All patients in REIN having initiated HD from 2010 to 2013 were classified according to their exposure to the different dialysate calcium concentrations in their dialysis unit. Data on the individual patients' treatments for MBD were extracted from the French national health database. Cox proportional hazard models were used to estimate mortality hazard ratios (HR) associated with time-dependent exposure to dialysate calcium concentrations and MBD therapies, adjusted for comorbidities, laboratory and technical data. RESULTS: Dialysate calcium concentration of 1.5 mmol/L was used by 81% of the dialysis centers in 2010 and in 83% in 2014. Most centers were using several formulas in up to 78% for 3 formulas in 2010 to 86% in 2014. In full adjusted Cox survival analyses, the percentage of calcium >1.5 mmol/L and <1.5 mmol/l by center and the number of formula used per center were not associated with survival. Depending on the daily dose used, the MBD therapies were associated with survival improvement for calcium, native vitamin D, active vitamin D, sevelamer, lanthanum and cinacalcet in the second and third tertiles of dose. CONCLUSION: No influence of the dialysate calcium concentration was evidenced on survival whereas all MBD therapies were associated with a survival improvement depending on the daily dose used.


Assuntos
Osso e Ossos/efeitos dos fármacos , Cálcio/análise , Soluções para Hemodiálise/análise , Sistema de Registros , Diálise Renal , Insuficiência Renal Crônica/terapia , Idoso , Vasos Sanguíneos/efeitos dos fármacos , Vasos Sanguíneos/metabolismo , Vasos Sanguíneos/fisiopatologia , Osso e Ossos/metabolismo , Osso e Ossos/fisiopatologia , Calcinose/epidemiologia , Calcinose/metabolismo , Calcinose/fisiopatologia , Cálcio/administração & dosagem , Cálcio/metabolismo , Cinacalcete/análise , Feminino , França/epidemiologia , Soluções para Hemodiálise/administração & dosagem , Soluções para Hemodiálise/química , Humanos , Lantânio/análise , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/mortalidade , Insuficiência Renal Crônica/fisiopatologia , Sevelamer/análise , Vitamina D/análise , Vitamina D/metabolismo
15.
Nephron Clin Pract ; 112(1): c9-15, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19342864

RESUMO

BACKGROUND/AIMS: The application of electrolyzed water (EW) at the cathode side to manufacture reverse osmosis (RO) water and hemodialysis (HD) solution can actually lead to less oxidative capacity in chemical terms. The present study examined the biological actions of this water on human polymorphonuclear leukocytes (PMNs), and the clinical feasibility of applying this technology to HD treatment. METHODS: RO water using EW (e-RO) exhibited less chemiluminescence in luminol-hydrogen peroxide and higher dissolved hydrogen levels (-99.0 ppb) compared with control RO water. The effects of e-RO on PMN viability were tested. HD using e-RO was performed for 12 consecutive sessions in 8 patients for the feasibility test. RESULTS: Basal cellular viability and function to generate superoxide radicals of PMNs were better preserved by e-RO application. In the clinical trial, reductions of blood pressure were noted, but no adverse events were observed. There were no changes in the blood dialysis parameters, although methylguanidine levels were significantly decreased at the end of study. CONCLUSION: The present study demonstrated the capacity of e-RO to preserve the viability of PMNs, and the clinical feasibility of applying this water for HD treatment. The clinical application of this technology may improve the bio-compatibility of HD treatment.


Assuntos
Eletrólise , Soluções para Hemodiálise/farmacologia , Água/farmacologia , Adulto , Idoso , Citocromos c/metabolismo , Eletrodos , Estudos de Viabilidade , Feminino , Soluções para Hemodiálise/análise , Hemodinâmica/efeitos dos fármacos , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Medições Luminescentes , Masculino , Pessoa de Meia-Idade , Neutrófilos/efeitos dos fármacos , Neutrófilos/metabolismo , Osmose , Oxirredução , Estresse Oxidativo , Aldeído Pirúvico/sangue , Diálise Renal , Explosão Respiratória/efeitos dos fármacos , Superóxidos/metabolismo , Água/química
16.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 34(10): 1029-35, 2009 Oct.
Artigo em Zh | MEDLINE | ID: mdl-19893257

RESUMO

OBJECTIVE: To determine the morphology, bacteria and endotoxin content of biofilms on the inner surface of PVC tubes in hemodialysis water treatment system. METHODS: We dissolved biofilms of segments before and after reverse osmosis machine for bacterial count and identification. We studied biofilm structure of segments before and after reverse osmosis machine with eyes and scanning electron microscope. Biofilms of all 7 segments were dissolved for qualitative and quantitative assay of endotoxin. RESULTS: The inner surface of segment before reverse osmosis machine was homogeneously distributed with activated carbon powder deposition. The segment after reverse osmosis machine was normal. With scanning electron microscope, biofilm with successive surface and sandwich was found on the inner surface of segment before reverse osmosis machine, formed by clustering bacillus, activated carbon powder and some coccus. Bacteria of the same shape and length were found on segment after reverse osmosis machine, but fewer and looser. Bacterial culture and identification showed the former was mostly gram-negative bacillus, the latter was only a few micrococcus. Endotoxin of biofilm was between 2.0 EU/mL and 4.0 EU/mL. Quantitative assay showed: segment after softener (2.821+/-0.807) EU/mL; segment after active charcoal canister(3.635+/-0.427) EU/mL; segment before reverse osmosis machine (3.687+/-0.271) EU/mL; segment after reverse osmosis machine (2.041+/-0.295) EU/mL; exit of power pump (1.983+/-0.390)EU/mL;the 1st dead space (2.373+/-0.535) EU/mL; and the 2nd dead space (2.858+/-0.690)EU/mL. CONCLUSION: Biofilms are found on the inner surface of segment before and after reverse osmosis machine. Endotoxin level from high to low is as follows: segment before reverse osmosis machine, segment after active charcoal canister, the 2nd dead space, segment after softener, the 1st dead space, segment after reverse osmosis machine, exit of power pump. The character of the bacteria and endotoxin of the biofilm can help us find better ways to control them.


Assuntos
Bactérias , Biofilmes/crescimento & desenvolvimento , Contaminação de Equipamentos/prevenção & controle , Soluções para Hemodiálise/análise , Diálise Renal/instrumentação , Bactérias/crescimento & desenvolvimento , Bactérias/isolamento & purificação , Unidades Hospitalares de Hemodiálise , Lipopolissacarídeos/análise , Cloreto de Polivinila , Microbiologia da Água
18.
Nephrol Dial Transplant ; 23(10): 3280-2, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18436563

RESUMO

BACKGROUND: Gd-related nephrogenic systemic fibrosis was successfully treated with intravenous sodium thiosulfate according to a recent case report. METHODS: Four haemodialysis patients with severe Gd-related nephrogenic systemic fibrosis were treated with intravenous sodium thiosulfate for 3-5 months. Symptoms and patients' experiences were investigated. The dialysate Gd content was monitored. RESULTS: We observed no major clinical improvements in any patient. In one patient, we found slightly improved joint motion. Two patients had a subjective impression of slight improvements of joint motion and skin abnormalities. The dialysate Gd content was raised by the treatment, up to fivefold. CONCLUSIONS: We could not confirm that sodium thiosulfate treatment results in marked and rapid improvement in late stages of Gd-related nephrogenic systemic fibrosis. However, dialysate contents of Gd seemed to increase. It is unknown whether increased Gd excretion will lead to long-term clinical improvements in late stages of nephrogenic systemic fibrosis.


Assuntos
Gadolínio/efeitos adversos , Gadolínio/farmacocinética , Dermopatia Fibrosante Nefrogênica/tratamento farmacológico , Dermopatia Fibrosante Nefrogênica/etiologia , Tiossulfatos/uso terapêutico , Adulto , Quelantes/uso terapêutico , Meios de Contraste/efeitos adversos , Meios de Contraste/farmacocinética , Feminino , Gadolínio DTPA/efeitos adversos , Gadolínio DTPA/farmacocinética , Soluções para Hemodiálise/análise , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Pessoa de Meia-Idade , Dermopatia Fibrosante Nefrogênica/metabolismo , Dermopatia Fibrosante Nefrogênica/prevenção & controle , Diálise Renal , Insuficiência Renal/diagnóstico , Fatores de Tempo
19.
J Nephrol ; 21(3): 384-93, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18587727

RESUMO

AIM: The incidence rate for sudden death in hemodialysis patients ranges between 2% and 7%. This phenomenon is frequently due to cardiac arrhythmias. In particular, the process of potassium (K(+)) depuration performed during hemodialysis has been found to be related to arrhythmia onset. The main aim of this study was to introduce a simple double-pool mathematical model of K(+) kinetics to investigate the effects of dialysate K(+) concentration on intracellular and extracellular K(+) removal. The secondary aim was to evaluate the K(+) removed from the different body pools in 2 different types of K(+) dialysate: constant and profiled. METHODS: Our model evaluated K(+) removal and body water in the intracellular and extracellular spaces using plasma, erythrocytes and spent dialysate K(+) concentration, and intracellular and extracellular volume (t=0) in 6 patients (4 females and 2 males). All patients were treated with acetate-free biofiltration with a constant K(+) dialysate concentration (AFB) and with a profiled one (AFB-K). Moreover, the electrolyte concentration (sodium, calcium and bicarbonate) and pH were analyzed in all sessions. RESULTS: A similar total potassium removal was evaluated by the model, starting from a similar final K(+) plasma reduction. At 10 minutes, the model assessed a higher K(+) removal in the extracellular space during AFB (26.6% vs. 7.7%, p<0.001) involving a lower K(+) concentration (5.0 +/- 0.5 in AFB and 5.2 +/- 0.6 in AFB-K, p<0.05) and consequently a higher cell hyperpolarization (-73.4 +/- 3.9 mV vs. -72.1 +/- 2.4 mV, p=0.05). No differences in pH, intracellular and extracellular Na+ or plasma Ca(2+) were highlighted between AFB and AFB-K. CONCLUSIONS: The model we developed allows us to evaluate K(+) removal and body water in the intracellular and extracellular spaces during treatment. The assessment of this information may have a relevant role toward an understanding of the causes of the Nernst potential changes during hemodialysis that are often related to the onset of arrhythmias.


Assuntos
Líquido Extracelular/metabolismo , Líquido Intracelular/metabolismo , Modelos Biológicos , Potássio/metabolismo , Diálise Renal , Água Corporal/fisiologia , Feminino , Soluções para Hemodiálise/análise , Humanos , Transporte de Íons , Masculino , Pletismografia de Impedância , Potássio/análise
20.
J Pharm Biomed Anal ; 46(3): 534-42, 2008 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-18096349

RESUMO

High turbulence liquid chromatography (HTLC, or turbulent flow online extraction) and tandem mass spectrometry (MS/MS) methods for the determination of sitagliptin in human urine and hemodialysate were developed and validated to support clinical studies. A narrow bore large particle size reversed-phase column (Cyclone, 50 mm x 1.0 mm, 60 microm) and a BDS Hypersil C18 column (30 mm x 2.1 mm, 3 microm) were used as extraction and analytical columns, respectively. For the urine assay, the LLOQ was 0.1 microg/ml, the linear calibration range was 0.1 to 50 microg/ml, the interday precision (R.S.D.%, n=5) was 2.3-6.5%, and the accuracy was 96.9-106% of the nominal value. For the urine quality control samples (QCs), the intraday precision (R.S.D.%, n=5) and accuracy were 1.8-2.6% and 96.2-106% of the nominal value, respectively. The interday precision (R.S.D.%) for 56 sets of urine QCs over a 6-month period varied from 3.8% to 5.5% and the accuracy from 102% to 105% of the nominal value. For the hemodialysate assay, the LLOQ was 0.01 ng/ml, the linear dynamic range was 0.01-5.0 ng/ml, the interday precision was 1.6-4.1%, and the accuracy was 89.8-104% of the nominal value. For hemodialysate QCs, the intraday precision and accuracy varied from 2.3% to 8.9% and from 99.8% to 111% of the nominal value, respectively. These results demonstrated that both methods are selective, accurate, precise, reproducible, and suitable for quantifying sitagliptin in hemodialysate and human urine samples.


Assuntos
Cromatografia Líquida/métodos , Soluções para Hemodiálise/análise , Pirazinas/análise , Espectrometria de Massas em Tandem/métodos , Triazóis/análise , Calibragem , Estabilidade de Medicamentos , Humanos , Pirazinas/urina , Sensibilidade e Especificidade , Fosfato de Sitagliptina , Triazóis/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA