Your browser doesn't support javascript.
loading
Models for estimation of the (10)B concentration after BPA-fructose complex infusion in patients during epithermal neutron irradiation in BNCT.
Ryynänen, P M; Kortesniemi, M; Coderre, J A; Diaz, A Z; Hiismäki, P; Savolainen, S E.
Afiliación
  • Ryynänen PM; Department of Physics, University of Helsinki, Helsinki, Finland.
Int J Radiat Oncol Biol Phys ; 48(4): 1145-54, 2000 Nov 01.
Article en En | MEDLINE | ID: mdl-11072174
ABSTRACT

PURPOSE:

To create simple and reliable models for clinical practice for estimating the blood (10)B time-concentration curve after p-boronophenylalanine fructose complex (BPA-F) infusion in patients during neutron irradiation in boron neutron capture therapy (BNCT). METHODS AND MATERIALS BPA-F (290 mg BPA/kg body weight) was infused i.v. during two hours to 10 glioblastoma multiforme patients. Blood samples were collected during and after the infusion. Compartmental models and bi-exponential function fit were constructed based on the (10)B blood time-concentration curve. The constructed models were tested with data from six additional patients who received various amounts of infused BPA-F and data from one patient who received a one-hour infusion of 170 mg BPA/kg body weight.

RESULTS:

The resulting open two-compartment model and bi-exponential function estimate the clearance of (10)B after 290 mg BPA/kg body weight infusion from the blood with satisfactory accuracy during the first irradiation field (1 ppm, i.e., 7%). The accuracy of the two models in predicting the clearance of (10)B during the second irradiation field are for two-compartment model 1.0 ppm (8%) and 0.2 ppm (2%) for bi-exponential function. The models predict the average blood (10)B concentration with an increasing accuracy as more data points are available during the treatment.

CONCLUSION:

By combining the two models, a robust and practical modeling tool is created for the estimation of the (10)B concentration in blood after BPA-F infusion.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fármacos Sensibilizantes a Radiaciones / Boro / Neoplasias Encefálicas / Compuestos de Boro / Terapia por Captura de Neutrón de Boro / Glioblastoma / Fructosa / Modelos Biológicos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Int J Radiat Oncol Biol Phys Año: 2000 Tipo del documento: Article País de afiliación: Finlandia
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fármacos Sensibilizantes a Radiaciones / Boro / Neoplasias Encefálicas / Compuestos de Boro / Terapia por Captura de Neutrón de Boro / Glioblastoma / Fructosa / Modelos Biológicos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Int J Radiat Oncol Biol Phys Año: 2000 Tipo del documento: Article País de afiliación: Finlandia