Your browser doesn't support javascript.
loading
Liquid chromatography analysis of N-(2-mercaptopropionyl)-glycine in biological samples by ThioGlo 3 derivatization.
Penugonda, Suman; Wu, Wei; Mare, Suneetha; Ercal, Nuran.
Afiliación
  • Penugonda S; Department of Chemistry, University of Missouri-Rolla, 1870 Miner Circle, Rolla, MO 65409, USA.
Article en En | MEDLINE | ID: mdl-15203037
ABSTRACT
N-(2-Mercaptopropionyl)-glycine (MPG) is a synthetic aminothiol antioxidant that is used in the treatment of cystinuria, rheumatoid arthritis, liver and skin disorders. Recent studies have shown that MPG can function as a chelating, cardioprotecting and a radioprotecting agent. Several other studies have shown that it may also act as a free radical scavenger because of its thiol group. Thiol-containing compounds have been detected in biological samples by various analytical methods such as spectrophotometric and colorimetric methods. However, these methods require several milliliters of a sample, time-consuming procedures and complicated derivatization steps, as well as having high detection limits. The present study describes a rapid, sensitive and relatively simple method for detecting MPG in biological tissues by using reverse-phase HPLC. With ThioGlo 3 [3H-Naphto[2,1-b] pyran, 9-acetoxy-2-(4-(2,5-dihydro-2,5-dioxo-1H-pyrrol-1-yl) phenyl-3-oxo-)] as the reagent, highly fluorescent derivatives of thiols can be obtained that are suitable for HPLC. MPG is derivatized with ThioGlo 3 and is then detected flourimetrically by reverse phase HPLC using a C18 column as the stationary phase. Acetonitrile Water (7525) with acetic acid and phosphoric acid (1 mL/L) is used as the mobile phase (excitation wavelength, 365 nm; emission wavelength, 445 nm). The calibration curve for MPG is linear over a range of 10-2500 nM (r=0.999) and the coefficients of the variation of within-run and between-run precision were found to be 0.3 and 2.1%, respectively. The detection limit was 5.07 nM per 20 microL injection volume. Quantitative relative recovery of MPG in the biological samples (plasma, lung, liver, kidney and brain) ranged from 90+/-5.3 to 106.7+/-9.3 %. Based on these results, we have concluded that this method is suitable for determining MPG in biological samples.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Piranos / Pirroles / Encéfalo / Cromatografía Líquida de Alta Presión / Colorantes Fluorescentes / Riñón / Pulmón / Tiopronina Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2004 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Piranos / Pirroles / Encéfalo / Cromatografía Líquida de Alta Presión / Colorantes Fluorescentes / Riñón / Pulmón / Tiopronina Tipo de estudio: Diagnostic_studies Límite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2004 Tipo del documento: Article País de afiliación: Estados Unidos