Complications of carotid artery stenting are largely preventable: a retrospective error analysis.
Perspect Vasc Surg Endovasc Ther
; 19(4): 403-8, 2007 Dec.
Article
en En
| MEDLINE
| ID: mdl-18287152
Procedure-related complications with carotid artery stenting must be minimized for it to be a valid treatment for carotid stenosis. Failure analysis was done for 207 carotid stent procedures. All complications were reviewed and technical errors were identified. The procedure-related stroke rate was 2.9%, technical failure rate was 1.9%, and no patients died. Two strokes resulted from protocol deviations. A third stroke occurred while crossing a long, irregular lesion with a protection device instead of establishing flow reversal. Excessive instrumentation of the aortic arch resulted in 2 strokes. Distal embolization occurred after open-cell stenting a friable lesion in 1 patient. The majority of neurologic events and technical complications that occur during carotid stenting are preventable. By adhering to technical protocols, avoiding excessive instrumentation in the aortic arch, using flow reversal in selected lesions, and matching the appropriate anatomy and stent, results of carotid artery stenting can be exceptional.
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Complicaciones Posoperatorias
/
Stents
/
Angioplastia
/
Accidente Cerebrovascular
Tipo de estudio:
Diagnostic_studies
/
Guideline
/
Risk_factors_studies
Límite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Perspect Vasc Surg Endovasc Ther
Asunto de la revista:
ANGIOLOGIA
Año:
2007
Tipo del documento:
Article
País de afiliación:
Estados Unidos