Your browser doesn't support javascript.
loading
EBUS-TBNA for the clarification of PET positive intra-thoracic lymph nodes-an international multi-centre experience.
Rintoul, Robert C; Tournoy, Kurt G; El Daly, Hesham; Carroll, Nicholas R; Buttery, Robert C; van Kralingen, Klaas; van Meerbeeck, Jan P; Rabe, Klaus F; Annema, Jouke T.
Afiliación
  • Rintoul RC; Department of Thoracic Oncology, Papworth Hospital, Cambridge, United Kingdom. robert.rintoul@papworth.nhs.uk
J Thorac Oncol ; 4(1): 44-8, 2009 Jan.
Article en En | MEDLINE | ID: mdl-19096305
ABSTRACT

INTRODUCTION:

To determine the sensitivity and accuracy of endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) for clarification of the nature of fluorodeoxyglucose-positron emission tomography (FDG) positive hilar and/or mediastinal lymph nodes in patients with (suspected) lung cancer.

METHODS:

All consecutive patients who had undergone EBUS-TBNA alone for assessment of abnormal FDG-uptake in hilar and/or mediastinal lymph nodes between January 2005 and August 2007 were reviewed.

RESULTS:

One-hundred-nine patients underwent EBUS-TBNA of 127 positron emission tomography positive lymph nodes. Hilar (station 10 or 11) nodes (N1 or N3) were aspirated in 26 patients and mediastinal (stations 2, 4, 7) nodes (N2 or N3) in 90 patients. In 7 patients both hilar and mediastinal nodes were sampled. There were no procedure-related complications. Malignancy was detected in 77 (71%) cases. Thirty-two patients were tumor negative by EBUS-TBNA; subsequent surgical biopsy in 19 showed malignancy in 7. In four cases the false negative result was due to sampling error and in three cases due to detection error. In 13 cases surgical staging was not performed although long term follow-up in 3 showed no evidence of malignancy. The sensitivity and accuracy of EBUS-TBNA for malignancy in patients with reference pathology was 91% and 92%, respectively. The negative predictive value was 60%. If the 10 cases for which confirmatory surgical staging was not performed are assumed to be false negative results, overall sensitivity and accuracy were 82% and 84%, respectively.

CONCLUSIONS:

EBUS-TBNA offers an effective accurate, minimally invasive strategy for evaluating FDG avid hilar and mediastinal lymph nodes. However, negative findings should be confirmed by surgical staging.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Endosonografía / Tomografía de Emisión de Positrones / Neoplasias Pulmonares / Ganglios Linfáticos / Neoplasias del Mediastino Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Thorac Oncol Año: 2009 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Endosonografía / Tomografía de Emisión de Positrones / Neoplasias Pulmonares / Ganglios Linfáticos / Neoplasias del Mediastino Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Thorac Oncol Año: 2009 Tipo del documento: Article País de afiliación: Reino Unido