Your browser doesn't support javascript.
loading
Field evaluation of diagnostic accuracy of an oral fluid rapid test for HIV, tested at point-of-service sites in rural Zimbabwe.
Pascoe, Sophie J S; Langhaug, Lisa F; Mudzori, James; Burke, Eileen; Hayes, Richard; Cowan, Frances M.
Afiliación
  • Pascoe SJ; Department of Epidemiology and Population Health, London School of Hygiene and Tropical Medicine, London, United Kingdom. sophie.pascoe@lshtm.ac.uk
AIDS Patient Care STDS ; 23(7): 571-6, 2009 Jul.
Article en En | MEDLINE | ID: mdl-19530953
ABSTRACT
The objective of this study was to validate the use of OraQuick ADVANCE Rapid HIV-1/2 Antibody test (OraSure Technologies Inc., Bethlehem, PA) on oral fluid for a population-based HIV prevalence survey of rural youth in southeast Zimbabwe. The evaluation was conducted in patients presenting for voluntary counseling and testing at rural clinics. Each participant provided an oral fluid sample tested using OraQuick ADVANCE. In addition, dried blood specimens were collected and tested blind at the National Microbiology Reference Laboratory in Harare using two enzyme-linked immunosorbent assays (ELISA; Vironostika, Biomérieux BV, Boxtel, The Netherlands and Ani Labsystems, Ltd., Vantaa, Finland) with confirmatory Western blot (MP Diagnostics [formerly Genelabs Diagnostics], Medical Technology Promedt Consulting GMBH, St. Ingbert, Germany) for samples with discrepant results. Diagnostic accuracy of the oral fluid assay was determined against the ELISA/Western blot algorithm as gold standard. Five hundred and ninety-one participants took part in the study between February and July 2006. Sensitivity of the test on oral fluid was 100% (95% confidence interval [CI] 97.9-100), and specificity was 100% (95% CI 99.1-100). HIV prevalence based on the reference standard was 29.8% (95% CI 26.1-33.5). This is one of the first validations of this rapid assay on oral fluid conducted in a general population to be reported in Africa. While there are some limitations with the assay (e.g., unlikely to detect those in early stages of HIV infection or with reduced viral load; altered accuracy in pregnancy) these limitations also apply to other rapid assays. The results showed the assay to be 100% accurate in determining HIV status, performed well in field settings, and can be considered suitable for use in epidemiologic surveys aiming to estimate HIV prevalence in general populations.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Juego de Reactivos para Diagnóstico / Saliva / Serodiagnóstico del SIDA / Infecciones por VIH Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prevalence_studies / Risk_factors_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Africa Idioma: En Revista: AIDS Patient Care STDS Asunto de la revista: DOENCAS SEXUALMENTE TRANSMISSIVEIS / SINDROME DA IMUNODEFICIENCIA ADQUIRIDA (AIDS) Año: 2009 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Juego de Reactivos para Diagnóstico / Saliva / Serodiagnóstico del SIDA / Infecciones por VIH Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prevalence_studies / Risk_factors_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Africa Idioma: En Revista: AIDS Patient Care STDS Asunto de la revista: DOENCAS SEXUALMENTE TRANSMISSIVEIS / SINDROME DA IMUNODEFICIENCIA ADQUIRIDA (AIDS) Año: 2009 Tipo del documento: Article País de afiliación: Reino Unido