Your browser doesn't support javascript.
loading
[Effects of polyethylene oxide at different concentrations on abdominal aortic blood flow and vascular resistance in rats].
Hu, Feng; DU, Rong-sheng; Zha, Dao-gang; Chen, Xiang-hui; Li, Sheng-hui; Zhou, Bing-jie; Liu, Yi-li.
Afiliación
  • Hu F; Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou 510515, China. huf2007@163.com
Nan Fang Yi Ke Da Xue Xue Bao ; 30(4): 884-7, 2010 Apr.
Article en Zh | MEDLINE | ID: mdl-20423873
ABSTRACT

OBJECTIVE:

To observe the effect of polyethylene oxide (PEO) solution at different concentrations on abdominal aortic blood flow and vascular resistance in rats and evaluate the safety and drag-reducing effect of PEO solution.

METHODS:

Thirty-two rats were anesthetized and randomly divided into 4 groups. An ultrasonic flow probe was deployed on the abdominal aorta (5 mm above the common iliac artery) to measure the blood flow. The carotid artery pressure, iliac artery pressure, iliac vein pressure, central venous pressure (CVP) and ECG were also monitored. Saline or different concentrations of PEO [(1x10(-6)(low), 1x10(-5)(middle) and 5x10(-5)(high) g/ml)] were injected in the 4 groups of rats through the caudal vein at a constant rate of 5 ml/h for 20 min, and the changes of the vascular resistance was observed. RESULTS After injections of 1x10(-6) and 1x10(-5) g/ml PEO, the abdominal aortic flow increased significantly (P<0.05) while the vascular resistance was reduced (P(low)=0.052, P(middle)<0.001) as compared to those in the saline control group. Following the injection with 5x10(-5) g/ml PEO, the abdominal aortic flow increased to a threshold in the initial 4 min, after which it rapidly decreased to approach the baseline levels despite continuous infusion. Blood pressure remained stable after the injections except for 5x10(-5) g/mlPEO injection, which resulted in a reduction of the blood pressure by about 10 mmHg (P=0.014). The heart rate and CVP both underwent no significant changes following the injections.

CONCLUSION:

The drag-reducing effect of PEO is closely related to its concentration, and compared with 1x10(-6) g/ml, 1x10(-5) g/ml PEO more effectively increases the blood flow and decreases the resistance. The effectiveness and safety of EPO are attenuated at a concentration higher than 5x10(-5) g/ml.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aorta Abdominal / Polietilenglicoles / Resistencia Vascular / Velocidad del Flujo Sanguíneo Límite: Animals Idioma: Zh Revista: Nan Fang Yi Ke Da Xue Xue Bao Año: 2010 Tipo del documento: Article País de afiliación: China
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aorta Abdominal / Polietilenglicoles / Resistencia Vascular / Velocidad del Flujo Sanguíneo Límite: Animals Idioma: Zh Revista: Nan Fang Yi Ke Da Xue Xue Bao Año: 2010 Tipo del documento: Article País de afiliación: China