Clinical outcome and angiographic results with novel polysulfone polymer coating paclitaxel eluting stent in real-world clinical practice: a clinical centre registry.
Gavrielatos, Gerasimos; Anthopoulos, Prodromos L; Pappas, Loukas K; Gavaliatsis, Isidoros; Salachas, Anastasios; Ifantis, Georgios; Antonelis, Ioannis.
Afiliación
  • Gavrielatos G; 2nd Department of Cardiology, Evaggelismos General Hospital, Athens, Greece. makisgab@yahoo.gr
Med Sci Monit ; 16(10): MT77-82, 2010 Oct.
Article en En | MEDLINE | ID: mdl-20885360
BACKGROUND: The Intek-Apollo stent (Switzerland) employs a polysulfone polymer coating which has demonstrated low interaction with blood and high thrombo-resistance. The aim of this study was to assess the clinical and angiographic outcomes after Intek-Apollo stent utilisation in a real-world setting. MATERIAL/METHODS: A total of 130 patients (77.7% males) were enrolled with 174 lesions in native coronary arteries (92.4%), saphenous vein grafts (7.5%) and in-stent restenosis (6.3%). Indications for stenting were stable coronary artery disease (CAD) 52.3%, acute coronary syndrome (ACS) 37.7% and STEMI 10%. Clinical follow-up and coronary angiography (after symptoms occurrence or positive stress test) was performed at 6 and 12 months.The primary end points were target lesion revascularization (TLR) and target vessel revascularization (TVR), while secondary end points were major adverse cardiac events (MACE) during the follow-up period. RESULTS: The mean age of patients included was 61.62±11.13 years. Complex lesions treatment (ostial, bifurcation) reached 13.7%. Mean stenosis diameter was 83.52±10.5%. Reference vessel diameter was 2.85±0.39 mm with a mean lesion length of 14.66±4.5mm. Average stent size was 2.93±0.39mm × 16.6±4.73 mm. At 15±3 months, primary events included TLR (4.6%), TVR (4.6%) and MACE (2.3%). There was 1one myocardial infarction and no cardiac death). No incidence of early or late stent thrombosis was demonstrated. CONCLUSIONS: Intek-Apollo stent implantation is safe and efficient in a real world population. The unique properties of polysulfone polymer coating can effectively protect from late stent thrombosis and lead to reduced rates of TLR, TVR and MACE.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Paclitaxel / Stents Liberadores de Fármacos Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Med Sci Monit Asunto de la revista: MEDICINA Año: 2010 Tipo del documento: Article País de afiliación: Grecia
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Paclitaxel / Stents Liberadores de Fármacos Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Med Sci Monit Asunto de la revista: MEDICINA Año: 2010 Tipo del documento: Article País de afiliación: Grecia