Coronary CT angiography of patients with a normal body mass index using 80 kVp versus 100 kVp: a prospective, multicenter, multivendor randomized trial.
AJR Am J Roentgenol
; 197(5): W860-7, 2011 Nov.
Article
en En
| MEDLINE
| ID: mdl-22021533
OBJECTIVE: We determined the effect of reduced 80-kVp tube voltage on the radiation dose and image quality of coronary CT angiography (CTA) in patients with a normal body mass index (BMI). SUBJECTS AND METHODS: A prospective, multicenter, multivendor trial was performed of 208 consecutive patients with a normal BMI (< 25 kg/m(2)) who had been referred for coronary CTA and did not have a history of coronary revascularization. Patients were randomized to 80-kVp imaging (n = 103) or 100-kVp imaging (n = 105). Three blinded readers graded interpretability and image quality. Study signal, noise, and contrast were also compared. RESULTS: Imaging with 80 kVp instead of 100 kVp was associated with 47% lower median radiation dose (median dose-length product, 62.0 mGy · cm [interquartile range, 54.0-123.3 mGy · cm] vs 117.0 mGy · cm [110.0-225.9 mGy · cm], respectively; 0.9 mSv [0.8-1.7 mSv] vs 1.6 mSv [1.4-3.2 mSv]; p < 0.001 for each) with no significant difference in interpretability (99% vs 99%; p = 0.99) or image quality (median score, 4.0 [interquartile range, 3.6-4.0] vs 4.0 [interquartile range, 3.8-4.0]; p = 0.20). Studies obtained using 80 kVp were associated with 27% increased signal (mean ± SD, 756 ± 157 vs 594 ± 105 HU; p < 0.001), 25% higher contrast (890 ± 156 vs 709 ± 108 HU; p < 0.001), and 50% greater noise (55 ± 15 vs 37 ± 12 HU; p < 0.001) with resultant 15% and 16% decreases in signal-to-noise (mean ± SD, 15 ± 5 vs 17 ± 5; p < 0.001) and contrast-to-noise (mean ± SD, 17 ± 6 vs 21 ± 5; p < 0.001) ratios, respectively. CONCLUSION: Coronary CTA using 80 kVp instead of 100 kVp was associated with a nearly 50% reduction in radiation dose with no significant difference in interpretability and noninferior image quality despite lower signal-to-noise and contrast-to-noise ratios. The use of 80-kVp tube voltage should be considered in dose-reduction strategies for coronary CTA of individuals with a normal BMI.
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Tomografía Computarizada por Rayos X
/
Índice de Masa Corporal
/
Angiografía Coronaria
/
Enfermedad Coronaria
/
Técnicas de Imagen Sincronizada Cardíacas
Tipo de estudio:
Clinical_trials
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
AJR Am J Roentgenol
Año:
2011
Tipo del documento:
Article
País de afiliación:
Estados Unidos