Your browser doesn't support javascript.
loading
Water-fat separation with parallel imaging based on BLADE.
Weng, Dehe; Pan, Yanli; Zhong, Xiaodong; Zhuo, Yan.
Afiliación
  • Weng D; State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics, Chinese Academy of Sciences, 15 Datun Road, Chaoyang District, Beijing, 100101, P.R. China.
Magn Reson Imaging ; 31(5): 656-63, 2013 Jun.
Article en En | MEDLINE | ID: mdl-23290479
ABSTRACT
Uniform suppression of fat signal is desired in clinical applications. Based on phase differences introduced by different chemical shift frequencies, Dixon method and its variations are used as alternatives of fat saturation methods, which are sensitive to B0 inhomogeneities. Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) separates water and fat images with flexible echo shifting. Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER, alternatively termed as BLADE), in conjunction with IDEAL, yields Turboprop IDEAL (TP-IDEAL) and allows for decomposition of water and fat signal with motion correction. However, the flexibility of its parameter setting is limited, and the related phase correction is complicated. To address these problems, a novel method, BLADE-Dixon, is proposed in this study. This method used the same polarity readout gradients (fly-back gradients) to acquire in-phase and opposed-phases images, which led to less complicated phase correction and more flexible parameter setting compared to TP-IDEAL. Parallel imaging and undersampling were integrated to reduce scan time. Phantom, orbit, neck and knee images were acquired with BLADE-Dixon. Water-fat separation results were compared to those measured with conventional turbo spin echo (TSE) Dixon and TSE with fat saturation, respectively, to demonstrate the performance of BLADE-Dixon.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Algoritmos / Imagen por Resonancia Magnética / Agua / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Tejido Adiposo / Técnica de Sustracción / Artefactos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Magn Reson Imaging Año: 2013 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Algoritmos / Imagen por Resonancia Magnética / Agua / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Tejido Adiposo / Técnica de Sustracción / Artefactos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Magn Reson Imaging Año: 2013 Tipo del documento: Article