Your browser doesn't support javascript.
loading
Sensitive hydrophilic interaction liquid chromatography/tandem mass spectrometry method for rapid detection, quantification and confirmation of cathinone-derived designer drugs for doping control in equine plasma.
Li, Xiaoqing; Uboh, Cornelius E; Soma, Lawrence R; Liu, Ying; Guan, Fuyu; Aurand, Craig R; Bell, David S; You, Youwen; Chen, Jinwen; Maylin, George A.
Afiliación
  • Li X; University of Pennsylvania, School of Veterinary Medicine, Department of Clinical Studies, New Bolton Center Campus, Kennett Square, PA, 19348, USA.
Rapid Commun Mass Spectrom ; 28(2): 217-29, 2014 Jan 30.
Article en En | MEDLINE | ID: mdl-24338970
RATIONALE: Cathinone derivatives are new amphetamine-like stimulants that can evade detection when presently available methods are used for doping control. To prevent misuse of these banned substances in racehorses, development of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method became the impetus for undertaking this study. METHODS: Analytes were recovered via liquid-liquid extraction using methyl tert-butyl ether. Analyte separation was achieved on a hydrophilic interaction column using liquid chromatography and mass analysis was performed on a QTRAP mass spectrometer in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM). Analyte identification was carried out by screening for a specified MRM transition. Quantification was conducted using an internal standard. Confirmation was performed by establishing a match in retention time and ion intensity ratios comparison. RESULTS: The method was linear over the range 0.2-50 ng/mL. The specificity was evaluated by analysis of six different batches of blank plasma and those spiked with each analyte (0.2 ng/mL). The recovery of analytes from plasma at three different concentrations was >70%. The limits of detection, quantification and confirmation were 0.02-0.05, 0.2-1.0 and 0.2-10 ng/mL, respectively. The matrix effect was insignificant. The intra-day and inter-day precision were 1.94-12.08 and 2.58-13.32%, respectively. CONCLUSIONS: The method is routinely employed in screening for the eleven analytes in post-competition samples collected from racehorses in Pennsylvania to enforce the ban on the use of these performance-enhancing agents in racehorses. The method is sensitive, fast, effective and reliably reproducible.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Drogas de Diseño / Alcaloides / Espectrometría de Masas en Tándem / Caballos / Estimulantes del Sistema Nervioso Central Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Animals Idioma: En Revista: Rapid Commun Mass Spectrom Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Drogas de Diseño / Alcaloides / Espectrometría de Masas en Tándem / Caballos / Estimulantes del Sistema Nervioso Central Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Animals Idioma: En Revista: Rapid Commun Mass Spectrom Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos