Large false lumen area is a predictor of failed false lumen volume reduction after stent-graft repair in type B aortic dissection.
Kim, Tae-Hoon; Ko, Young-Guk; Kwon, Sung Woo; Choi, Donghoon; Lee, Do Yun; Shim, Won-Heum; Hyon, Min Su.
Afiliación
  • Kim TH; 1 Division of Cardiology, Sejong General Hospital, Bucheon, Korea.
J Endovasc Ther ; 21(5): 697-706, 2014 Oct.
Article en En | MEDLINE | ID: mdl-25290799
ABSTRACT

PURPOSE:

To investigate the predictors of failed false lumen (FL) volume reduction at 12 months after stent-graft implantation in patients with type B aortic dissection.

METHODS:

The retrospective analysis comprised 38 patients (25 men; mean age 60±12 years) with double-barrel type B aortic dissection (9 acute) treated with thoracic endovascular aortic repair (TEVAR) and evaluated with serial computed tomography (CT) scans up to 12 months. Aortic volume changes were determined. Based on FL volume change at 1 year after stent-graft implantation, patients were dichotomized according to the presence or absence of FL volume reduction. Clinical and CT variables were compared between groups to determine risk factors of failed FL volume reduction. A major adverse event (MAE) was defined as death or reintervention.

RESULTS:

Patients were followed for 4.2±2.8 years. FL volume reduction (+FLVR) occurred in 27 (71%) patients, whereas 11 (29%) patients had no FL volume reduction (-FLVR). The MAE-free survival rate was significantly higher in the +FLVR patients than in the -FLVR group (88.9% vs. 27.3%, respectively; p=0.001). Chronicity of dissection, location of tear site, or the maximum total aortic lumen area was not associated with failure to achieve FL volume reduction. However, the maximum preprocedure FL area was significantly lower in the +FLVR group than in the -FLVR group (12.6±6.6 vs. 21.0±11.4 cm(2), respectively; p=0.041) and was an independent predictor for failed FL volume reduction (odds ratio 1.3, 95% confidence interval 1.02 to 1.70, p=0.031).

CONCLUSION:

Failed FL volume reduction after TEVAR was associated with a significantly increased rate of mortality or reintervention during follow-up. A larger preprocedure maximum FL area was a predictor of failed FL volume reduction after TEVAR in type B dissection.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Torácica / Implantación de Prótesis Vascular / Procedimientos Endovasculares / Disección Aórtica Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Endovasc Ther Asunto de la revista: ANGIOLOGIA Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Torácica / Implantación de Prótesis Vascular / Procedimientos Endovasculares / Disección Aórtica Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Endovasc Ther Asunto de la revista: ANGIOLOGIA Año: 2014 Tipo del documento: Article