A micro-computed tomography evaluation of long-oval canal preparation using reciprocating or rotary systems.
Busquim, S; Cunha, R S; Freire, L; Gavini, G; Machado, M E; Santos, M.
Afiliación
  • Busquim S; Postgraduate Program in Endodontics, School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil.
  • Cunha RS; Department of Restorative Dentistry, College of Dentistry, University of Manitoba, Winnipeg, MB, Canada.
  • Freire L; Postgraduate Program in Endodontics, School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil.
  • Gavini G; Division of Endodontics, Department of Restorative Dentistry, School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil.
  • Machado ME; Division of Endodontics, Department of Restorative Dentistry, School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil.
  • Santos M; Division of Endodontics, Department of Restorative Dentistry, School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil.
Int Endod J ; 48(10): 1001-6, 2015 Oct.
Article en En | MEDLINE | ID: mdl-25314154
ABSTRACT

AIM:

To evaluate, using micro-computed tomography, the preparation of long-oval root canals using a single reciprocating system versus a multiple-file rotary system.

METHODOLOGY:

Distal canals of thirty mandibular molars were selected and randomly assigned to one of two instrument groups (n = 15) Reciproc 40 (VDW, Munich, Germany) or BioRaCe system (FKG Dentaire, La Chaux-de-Fonds, Switzerland). The teeth were scanned before and after preparation of the canal by a SkyScan 1172 micro-computed tomography scanner at 11-µm resolution. Morphometric variations were measured by volume increases and by the remaining untreated canal surface area in the entire canal and as well as in each third of the canal. Data were compared using the Mann-Whitney test.

RESULTS:

The Reciproc system left significantly more areas untouched (P < 0.001) in the cervical and middle thirds (18.14% and 21.82%) as compared to BioRaCe (8.14% and 11.35%). The Reciproc system had the greatest increase in volume of both the entire canal and the apical third (P < 0.5).

CONCLUSIONS:

Neither technique was able to completely prepare the outline of long-oval canals. The Reciproc system removed more tooth structure. The BioRaCe left fewer untouched dentine walls in the more coronal thirds of the canal, whilst Reciproc left fewer in the apical third.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Preparación del Conducto Radicular / Instrumentos Dentales / Microtomografía por Rayos X / Diente Molar Límite: Humans Idioma: En Revista: Int Endod J Año: 2015 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Preparación del Conducto Radicular / Instrumentos Dentales / Microtomografía por Rayos X / Diente Molar Límite: Humans Idioma: En Revista: Int Endod J Año: 2015 Tipo del documento: Article País de afiliación: Brasil