Your browser doesn't support javascript.
loading
18FDG-PET/CT Definition of Clinical Target Volume for Robotic Stereotactic Body Radiosurgery Treatment of Metastatic Gynecologic Malignancies.
Kunos, Charles A; Debernardo, Robert; Fabien, Jeffrey; Dobbins, Donald C; Zhang, Yuxia; Brindle, James; Faulhaber, Peter F.
Afiliación
  • Kunos CA; Departments of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio 44106, USA.
  • Debernardo R; Obstetrics and Gynecology Division of Gynecologic Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio 44106, USA.
  • Fabien J; Departments of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio 44106, USA.
  • Dobbins DC; Departments of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio 44106, USA.
  • Zhang Y; Departments of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio 44106, USA.
  • Brindle J; Departments of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio 44106, USA.
  • Faulhaber PF; Radiology Division of Nuclear Medicine, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio 44106, USA.
J Nucl Med Radiat Ther ; Suppl 4(1)2011 Dec 12.
Article en En | MEDLINE | ID: mdl-25506042
ABSTRACT
The objective of the current article was to evaluate 2-[18F]fluoro-2-deoxy-D-glucose 18F-FDG) as measured by positron emission tomography for delineation of abdominopelvic gross tumor volumes (GTV) for stereotactic body radiosurgery treatment (SBRT) of metastatic gynecologic cancers. A retrospective review of SBRT was conducted in 27 women with stage IV gynecologic cancers recurring in para-aortic lymph nodes. Robotic SBRT involved 2400 cGy in 3 consecutive 800 cGy daily fractions prescribed to a 3.0 mm expanded planning tumor volume (PTV) defined by both CT-based and 18F-FDG-based GTVs. In this study, 18F-FDG-based GTVs led to significantly larger PTVs in all 27 women, than if they had been based on CT GTVs alone (P < 0.001). Enlarged PTVs may have resulted from the breathing-induced target motion during the time of 18F-FDG image acquisition smearing 18F-FDG signal over a greater anatomic dimension. Ultimately, SBRT-target local control, based on the RECIST 1.1 criteria, was 96% (26 of 27), and associated with minor reversible toxicity. The use of 18F-FDG to define SBRT target volumes warrants further interrogation in SBRT clinical trials.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Nucl Med Radiat Ther Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Nucl Med Radiat Ther Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos