Your browser doesn't support javascript.
loading
Biosensor Enhancement Using Grooved Micromixers: Part II, Experimental Studies.
Lynn, N Scott; Bocková, Markéta; Adam, Pavel; Homola, Jirí.
Afiliación
  • Lynn NS; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, Prague, Czech Republic.
  • Bocková M; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, Prague, Czech Republic.
  • Adam P; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, Prague, Czech Republic.
  • Homola J; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, Prague, Czech Republic.
Anal Chem ; 87(11): 5524-30, 2015 Jun 02.
Article en En | MEDLINE | ID: mdl-25924027
ABSTRACT
In this study we examine the experimental use of the staggered herringbone mixer (SHM) for the signal enhancement of a microfluidic surface plasmon resonance imaging (SPRi) affinity-based biosensor. We define the signal enhancement (Emix) as the ratio of the time-dependent slope of the sensor response of a SHM-based microfluidic channel and that of an unmixed channel; Emix is directly proportional to changes in the sensor sensitivity and inversely proportional to changes in the sensor limit of detection (LOD). Measurements were carried out for three SHM designs under a wide range of volumetric flow rates for two analytes high diffusivity ssDNA and low diffusivity Escherichia coli bacteria. The experimental data collected in this study was found to exhibit a good match to that predicted by the numerical methods discussed in part I of this study. We found that Emix is dependent on the SHM groove geometry, the Péclet number Pe, and the overall microchannel length L; these dependencies are discussed in detail. For realistic experimental conditions, the enhancement that the SHM can provide is in the range of 1 < Emix < 5 (0% < improvement < 400%).
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Técnicas Biosensibles Tipo de estudio: Prognostic_studies Idioma: En Revista: Anal Chem Año: 2015 Tipo del documento: Article País de afiliación: República Checa

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Técnicas Biosensibles Tipo de estudio: Prognostic_studies Idioma: En Revista: Anal Chem Año: 2015 Tipo del documento: Article País de afiliación: República Checa