Your browser doesn't support javascript.
loading
Accelerator Mass Spectrometry of Actinides in Ground- and Seawater: An Innovative Method Allowing for the Simultaneous Analysis of U, Np, Pu, Am, and Cm Isotopes below ppq Levels.
Quinto, Francesca; Golser, Robin; Lagos, Markus; Plaschke, Markus; Schäfer, Thorsten; Steier, Peter; Geckeis, Horst.
Afiliación
  • Quinto F; †Karlsruhe Institute of Technology (KIT), Institute for Nuclear Waste Disposal (INE), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein Leopoldshafen, Germany.
  • Golser R; ‡VERA Laboratory, Faculty of Physics-Isotope Research and Nuclear Physics, University of Vienna, Währinger Straße 17, A-1090 Vienna, Austria.
  • Lagos M; †Karlsruhe Institute of Technology (KIT), Institute for Nuclear Waste Disposal (INE), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein Leopoldshafen, Germany.
  • Plaschke M; †Karlsruhe Institute of Technology (KIT), Institute for Nuclear Waste Disposal (INE), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein Leopoldshafen, Germany.
  • Schäfer T; †Karlsruhe Institute of Technology (KIT), Institute for Nuclear Waste Disposal (INE), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein Leopoldshafen, Germany.
  • Steier P; ‡VERA Laboratory, Faculty of Physics-Isotope Research and Nuclear Physics, University of Vienna, Währinger Straße 17, A-1090 Vienna, Austria.
  • Geckeis H; †Karlsruhe Institute of Technology (KIT), Institute for Nuclear Waste Disposal (INE), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein Leopoldshafen, Germany.
Anal Chem ; 87(11): 5766-73, 2015 Jun 02.
Article en En | MEDLINE | ID: mdl-25938849
(236)U, (237)Np, and Pu isotopes and (243)Am were determined in ground- and seawater samples at levels below ppq (fg/g) with a maximum sample size of 250 g. Such high sensitivity was possible by using accelerator mass spectrometry (AMS) at the Vienna Environmental Research Accelerator (VERA) with extreme selectivity and recently improved efficiency and a significantly simplified separation chemistry. The use of nonisotopic tracers was investigated in order to allow for the determination of (237)Np and (243)Am, for which isotopic tracers either are rarely available or suffer from various isobaric mass interferences. In the present study, actinides were concentrated from the sample matrix via iron hydroxide coprecipitation and measured sequentially without previous chemical separation from each other. The analytical method was validated by the analysis of the Reference Material IAEA 443 and was applied to groundwater samples from the Colloid Formation and Migration (CFM) project at the deep underground rock laboratory of the Grimsel Test Site (GTS) and to natural water samples affected solely by global fallout. While the precision of the presented analytical method is somewhat limited by the use of nonisotopic spikes, the sensitivity allows for the determination of ∼10(5) atoms in a sample. This provides, e.g., the capability to study the long-term release and retention of actinide tracers in field experiments as well as the transport of actinides in a variety of environmental systems by tracing contamination from global fallout.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Anal Chem Año: 2015 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Anal Chem Año: 2015 Tipo del documento: Article País de afiliación: Alemania