Sodium MRI of the human heart at 7.0 T: preliminary results.
Graessl, Andreas; Ruehle, Anjuli; Waiczies, Helmar; Resetar, Ana; Hoffmann, Stefan H; Rieger, Jan; Wetterling, Friedrich; Winter, Lukas; Nagel, Armin M; Niendorf, Thoralf.
Afiliación
  • Graessl A; Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany.
  • Ruehle A; Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany.
  • Waiczies H; MRI.TOOLS, Berlin, Germany.
  • Resetar A; Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Hoffmann SH; Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Rieger J; MRI.TOOLS, Berlin, Germany.
  • Wetterling F; Trinity College, Institute of Neuroscience, The University of Dublin, Ireland.
  • Winter L; Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany.
  • Nagel AM; Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Niendorf T; Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany.
NMR Biomed ; 28(8): 967-75, 2015 Aug.
Article en En | MEDLINE | ID: mdl-26082025
The objective of this work was to examine the feasibility of three-dimensional (3D) and whole heart coverage (23)Na cardiac MRI at 7.0 T including single-cardiac-phase and cinematic (cine) regimes. A four-channel transceiver RF coil array tailored for (23)Na MRI of the heart at 7.0 T (f = 78.5 MHz) is proposed. An integrated bow-tie antenna building block is used for (1)H MR to support shimming, localization and planning in a clinical workflow. Signal absorption rate simulations and assessment of RF power deposition were performed to meet the RF safety requirements. (23) Na cardiac MR was conducted in an in vivo feasibility study. 3D gradient echo (GRE) imaging in conjunction with Cartesian phase encoding (total acquisition time T(AQ) = 6 min 16 s) and whole heart coverage imaging employing a density-adapted 3D radial acquisition technique (T(AQ) = 18 min 20 s) were used. For 3D GRE-based (23)Na MRI, acquisition of standard views of the heart using a nominal in-plane resolution of (5.0 × 5.0) mm(2) and a slice thickness of 15 mm were feasible. For whole heart coverage 3D density-adapted radial (23)Na acquisitions a nominal isotropic spatial resolution of 6 mm was accomplished. This improvement versus 3D conventional GRE acquisitions reduced partial volume effects along the slice direction and enabled retrospective image reconstruction of standard or arbitrary views of the heart. Sodium cine imaging capabilities were achieved with the proposed RF coil configuration in conjunction with 3D radial acquisitions and cardiac gating. Cardiac-gated reconstruction provided an enhancement in blood-myocardium contrast of 20% versus the same data reconstructed without cardiac gating. The proposed transceiver array enables (23)Na MR of the human heart at 7.0 T within clinical acceptable scan times. This capability is in positive alignment with the needs of explorations that are designed to examine the potential of (23)Na MRI for the assessment of cardiovascular and metabolic diseases.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sodio / Imagen por Resonancia Cinemagnética / Imagenología Tridimensional / Imagen Molecular / Miocardio Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2015 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sodio / Imagen por Resonancia Cinemagnética / Imagenología Tridimensional / Imagen Molecular / Miocardio Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: NMR Biomed Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Año: 2015 Tipo del documento: Article País de afiliación: Alemania