Your browser doesn't support javascript.
loading
Quantitation of acotiamide in rat plasma by UHPLC-Q-TOF-MS: method development, validation and application to pharmacokinetics.
Patel, Prinesh N; Kalariya, Pradipbhai D; Swamy, Challa Veerabhadra; Gananadhamu, S; Srinivas, R.
Afiliación
  • Patel PN; Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research, Balanagar, Hyderabad, 500037, Telangana, India.
  • Kalariya PD; Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research, Balanagar, Hyderabad, 500037, Telangana, India.
  • Swamy CV; Department of Pharmacology, National Institute of Pharmaceutical Education and Research, Balanagar, Hyderabad, 500037, Telangana, India.
  • Gananadhamu S; Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research, Balanagar, Hyderabad, 500037, Telangana, India.
  • Srinivas R; Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research, Balanagar, Hyderabad, 500037, Telangana, India.
Biomed Chromatogr ; 30(3): 363-8, 2016 Mar.
Article en En | MEDLINE | ID: mdl-26153099
ABSTRACT
A novel, sensitive and selective ultra-high-performance liquid chromatography-electrospray ionization mass spectrometry method was developed and validated for the quantification of acotiamide (ACT), a first-in-class drug used in functional dyspepsia, in rat plasma. A simple protein precipitation method with acetonitrile as precipitating solvent was used to extract ACT from rat plasma. ACT and an internal standard (mirabegron, IS) were separated on an Agilent poroshell EC C18 column (50 × 3.0 mm, 2.7 µm) using methanol-10 mM ammonium acetate binary gradient mobile phase at a flow rate of 0.4 mL/min over 4 min run time. Detection was performed using target ions of [M + H](+) at m/z 451.2010 for ACT and m/z 397.1693 for IS in selective ion mode. The method was validated in the calibration range of 1.31-1000 ng/mL. All the validation parameters were well within the limits. The method demonstrated good performances in terms of intra- and inter-day precision (3.27-12.60% CV) and accuracy (87.96-104.94%). Thus the present ultra-high-pressure liquid chromatograhy-high-resolution mass spectrometry method for determination of ACT in rat plasma, is highly sensitive and rapid with a short run-time of 4 min, can be suitable for high sample throughput and for large batches of biological samples in pharmacokinetic studies. This method can be extended to measure plasma concentrations of ACT in humans to understand drug metabolism, drug interaction and adverse effects.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas / Tiazoles / Benzamidas / Cromatografía Líquida de Alta Presión Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Biomed Chromatogr Año: 2016 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas / Tiazoles / Benzamidas / Cromatografía Líquida de Alta Presión Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals Idioma: En Revista: Biomed Chromatogr Año: 2016 Tipo del documento: Article País de afiliación: India