Your browser doesn't support javascript.
loading
PRESBYOPIA OPTOMETRY METHOD BASED ON DIOPTER REGULATION AND CHARGE COUPLE DEVICE IMAGING TECHNOLOGY.
Zhao, Q; Wu, X X; Zhou, J; Wang, X; Liu, R F; Gao, J.
Afiliación
  • Zhao Q; Department of Ophthalmology, the Second Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Wu XX; Department of Ophthalmology, the Second Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Zhou J; Department of Ophthalmology, the Second Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Wang X; Department of Ophthalmology, the Second Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Liu RF; Department of Ophthalmology, the Second Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
  • Gao J; Department of Ophthalmology, the Second Hospital of Dalian Medical University, Dalian, Liaoning Province, China.
J Biol Regul Homeost Agents ; 29(3): 521-6, 2015.
Article en En | MEDLINE | ID: mdl-26403390
ABSTRACT
With the development of photoelectric technology and single-chip microcomputer technology, objective optometry, also known as automatic optometry, is becoming precise. This paper proposed a presbyopia optometry method based on diopter regulation and Charge Couple Device (CCD) imaging technology and, in the meantime, designed a light path that could measure the system. This method projects a test figure to the eye ground and then the reflected image from the eye ground is detected by CCD. The image is then automatically identified by computer and the far point and near point diopters are determined to calculate lens parameter. This is a fully automatic objective optometry method which eliminates subjective factors of the tested subject. Furthermore, it can acquire the lens parameter of presbyopia accurately and quickly and can be used to measure the lens parameter of hyperopia, myopia and astigmatism.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Optometría / Presbiopía / Microcomputadores / Diagnóstico por Imagen / Ojo Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Biol Regul Homeost Agents Asunto de la revista: BIOLOGIA / BIOQUIMICA Año: 2015 Tipo del documento: Article País de afiliación: China
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Optometría / Presbiopía / Microcomputadores / Diagnóstico por Imagen / Ojo Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Biol Regul Homeost Agents Asunto de la revista: BIOLOGIA / BIOQUIMICA Año: 2015 Tipo del documento: Article País de afiliación: China