Feasibility of Three-Dimensional MR Angiography Image Fusion Guidance for Endovascular Abdominal Aortic Aneurysm Repair.
Tacher, Vania; Desgranges, Pascal; You, Ketsakin; Ridouani, Fourat; Marzelle, Jean; Kobeiter, Hicham.
Afiliación
  • Tacher V; Department of Medical Imaging and Interventional Radiology, Henri Mondor Hospital, 51 avenue du Marechal de Lattre Tassigny, Créteil 94010, France.
  • Desgranges P; Department of Vascular Surgery, Henri Mondor Hospital, 51 avenue du Marechal de Lattre Tassigny, Créteil 94010, France.
  • You K; Department of Medical Imaging and Interventional Radiology, Henri Mondor Hospital, 51 avenue du Marechal de Lattre Tassigny, Créteil 94010, France.
  • Ridouani F; Department of Medical Imaging and Interventional Radiology, Henri Mondor Hospital, 51 avenue du Marechal de Lattre Tassigny, Créteil 94010, France.
  • Marzelle J; Department of Vascular Surgery, Henri Mondor Hospital, 51 avenue du Marechal de Lattre Tassigny, Créteil 94010, France.
  • Kobeiter H; Department of Medical Imaging and Interventional Radiology, Henri Mondor Hospital, 51 avenue du Marechal de Lattre Tassigny, Créteil 94010, France. Electronic address: hicham.kobeiter@gmail.com.
J Vasc Interv Radiol ; 27(2): 188-93, 2016 Feb.
Article en En | MEDLINE | ID: mdl-26830935
ABSTRACT
Magnetic resonance (MR) angiography image fusion (IF) with live fluoroscopy guidance was used while performing endovascular repair of abdominal aortic aneurysm (EVAR) in five patients with a history of chronic renal disease or severe contrast allergy. Intraprocedural technical success was 100%. Median procedure time was 120 minutes (range, 60-180 min), fluoroscopy time was 40 minutes (range, 17-65 min), dose-area product was 245,867 mGy × cm(2) (range, 68,435-690,053 mGy × cm(2)), and iodinated contrast volume injected was 15 mL (range, 0-40 mL). Technical success was achieved in four of five patients (80%); one case was complicated by a type 1 endoleak on follow-up MR angiography, which was successfully treated. EVAR with MR angiography IF guidance was technically feasible and safe in five patients and reduced or eliminated the use of iodinated contrast media.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Abdominal / Angiografía por Resonancia Magnética / Imagenología Tridimensional / Procedimientos Endovasculares Tipo de estudio: Guideline Límite: Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: J Vasc Interv Radiol Asunto de la revista: ANGIOLOGIA / RADIOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aneurisma de la Aorta Abdominal / Angiografía por Resonancia Magnética / Imagenología Tridimensional / Procedimientos Endovasculares Tipo de estudio: Guideline Límite: Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: J Vasc Interv Radiol Asunto de la revista: ANGIOLOGIA / RADIOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Francia