Setup accuracy for prone and supine whole breast irradiation.
Mulliez, Thomas; Gulyban, Akos; Vercauteren, Tom; van Greveling, Annick; Speleers, Bruno; De Neve, Wilfried; Veldeman, Liv.
Afiliación
  • Mulliez T; Department of Radiotherapy, University Hospital Ghent, De Pintelaan 185, 9000, Ghent, Belgium.
  • Gulyban A; Department of Radiotherapy, University Hospital Ghent, De Pintelaan 185, 9000, Ghent, Belgium.
  • Vercauteren T; Department of Radiotherapy, University Hospital Liege, Liege, Belgium.
  • van Greveling A; Department of Radiotherapy, University Hospital Ghent, De Pintelaan 185, 9000, Ghent, Belgium.
  • Speleers B; Department of Radiotherapy, University Hospital Ghent, De Pintelaan 185, 9000, Ghent, Belgium.
  • De Neve W; Department of Radiotherapy, University Hospital Ghent, De Pintelaan 185, 9000, Ghent, Belgium.
  • Veldeman L; Department of Radiotherapy, University Hospital Ghent, De Pintelaan 185, 9000, Ghent, Belgium.
Strahlenther Onkol ; 192(4): 254-9, 2016 Apr.
Article en En | MEDLINE | ID: mdl-26864048
PURPOSE: To evaluate cone-beam computed tomography (CBCT) based setup accuracy and margins for prone and supine whole breast irradiation (WBI). METHODS: Setup accuracy was evaluated on 3559 CBCT scans of 242 patients treated with WBI and uncertainty margins were calculated using the van Herk formula. Uni- and multivariate analysis on individual margins was performed for age, body mass index (BMI) and cup size. RESULTS: The population-based margin in vertical (VE), lateral (LA) and longitudinal (LO) directions was 10.4/9.4/9.4 mm for the 103 supine and 10.5/22.4/13.7 mm for the 139 prone treated patients, being significantly (p < 0.01) different for the LA and LO directions. Multivariate analysis identified a significant (p < 0.05) correlation between BMI and the LO margin in supine position and the VE/LA margin in prone position. CONCLUSION: In this series, setup accuracy is significantly worse in prone compared to supine position for the LA and LO directions. However, without proper image-guidance, uncertainty margins of about 1 cm are also necessary for supine WBI. For patients with a higher BMI, larger margins are required.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Planificación de la Radioterapia Asistida por Computador / Neoplasias de la Mama / Posición Supina / Posición Prona / Tomografía Computarizada de Haz Cónico / Posicionamiento del Paciente / Errores de Configuración en Radioterapia Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Strahlenther Onkol Asunto de la revista: NEOPLASIAS / RADIOTERAPIA Año: 2016 Tipo del documento: Article País de afiliación: Bélgica

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Planificación de la Radioterapia Asistida por Computador / Neoplasias de la Mama / Posición Supina / Posición Prona / Tomografía Computarizada de Haz Cónico / Posicionamiento del Paciente / Errores de Configuración en Radioterapia Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Strahlenther Onkol Asunto de la revista: NEOPLASIAS / RADIOTERAPIA Año: 2016 Tipo del documento: Article País de afiliación: Bélgica