Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Accelerates Pathogen Identification and May Confer Benefit in the Outcome of Peritoneal Dialysis-Related Peritonitis.
J Clin Microbiol
; 54(5): 1381-3, 2016 05.
Article
en En
| MEDLINE
| ID: mdl-26912750
ABSTRACT
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and conventional standard methods were compared for time to pathogen identification and impact on clinical outcomes in peritoneal dialysis-related peritonitis patients. The MALDI-TOF MS method identified the causative microorganisms earlier (average time saved, 64 h for all pathogens), and patients had a shorter hospital stay (mean ± standard deviation, 5.2 ± 4.8 days versus 8.2 ± 4.5 days, P = 0.001).