Your browser doesn't support javascript.
loading
Detection of Lymph Node Metastases with SERRS Nanoparticles.
Spaliviero, Massimiliano; Harmsen, Stefan; Huang, Ruimin; Wall, Matthew A; Andreou, Chrysafis; Eastham, James A; Touijer, Karim A; Scardino, Peter T; Kircher, Moritz F.
Afiliación
  • Spaliviero M; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
  • Harmsen S; Urology Service, Department of Surgery, Sidney Kimmel Center for Prostate and Urologic Cancers, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
  • Huang R; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
  • Wall MA; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
  • Andreou C; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
  • Eastham JA; Department of Chemistry, Hunter College of the City University of New York, New York, NY, 10065, USA.
  • Touijer KA; Department of Chemistry, The Graduate Center of the City University of New York, New York, NY, 10065, USA.
  • Scardino PT; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
  • Kircher MF; Urology Service, Department of Surgery, Sidney Kimmel Center for Prostate and Urologic Cancers, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
Mol Imaging Biol ; 18(5): 677-85, 2016 10.
Article en En | MEDLINE | ID: mdl-26943129
PURPOSE: The accurate detection of lymph node metastases in prostate cancer patients is important to direct treatment decisions. Our goal was to develop an intraoperative imaging approach to distinguish normal from metastasized lymph nodes. We aimed at developing and testing gold-silica surface-enhanced resonance Raman spectroscopy (SERRS) nanoparticles that demonstrate high uptake within normal lymphatic tissue and negligible uptake in areas of metastatic replacement. PROCEDURES: We evaluated the ability of SERRS nanoparticles to delineate lymph node metastases in an orthotopic prostate cancer mouse model using PC-3 cells transduced with mCherry fluorescent protein. Tumor-bearing mice (n = 6) and non-tumor-bearing control animals (n = 4) were injected intravenously with 30 fmol/g SERRS nanoparticles. After 16-18 h, the retroperitoneal lymph nodes were scanned in situ and ex vivo with a Raman imaging system and a handheld Raman scanner and data corroborated with fluorescence imaging for mCherry protein expression and histology. RESULTS: The SERRS nanoparticles demonstrated avid homing to normal lymph nodes, but not to metastasized lymph nodes. In cases where lymph nodes were partially infiltrated by tumor cells, the SERRS signal correctly identified, with sub-millimeter precision, healthy from metastasized components. CONCLUSIONS: This study serves as a first proof-of-principle that SERRS nanoparticles enable high precision and rapid intraoperative discrimination between normal and metastasized lymph nodes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Espectrometría Raman / Nanopartículas / Metástasis Linfática Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals / Humans / Male Idioma: En Revista: Mol Imaging Biol Asunto de la revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Espectrometría Raman / Nanopartículas / Metástasis Linfática Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Animals / Humans / Male Idioma: En Revista: Mol Imaging Biol Asunto de la revista: BIOLOGIA MOLECULAR / DIAGNOSTICO POR IMAGEM Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos