Separation of collagen-bound and porous bone-water longitudinal relaxation in mice using a segmented inversion recovery zero-echo-time sequence.
Marcon, Magda; Keller, Daniel; Wurnig, Moritz C; Weiger, Markus; Kenkel, David; Eberhardt, Christian; Eberli, Daniel; Boss, Andreas.
Afiliación
  • Marcon M; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland.
  • Keller D; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland.
  • Wurnig MC; Department of Urology, University Hospital Zurich, Switzerland.
  • Weiger M; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland.
  • Kenkel D; Institute for Biomedical Engineering, University of Zurich and Swiss Federal Institute for Technology, Zurich, Switzerland.
  • Eberhardt C; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland.
  • Eberli D; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland.
  • Boss A; Department of Urology, University Hospital Zurich, Switzerland.
Magn Reson Med ; 77(5): 1909-1915, 2017 05.
Article en En | MEDLINE | ID: mdl-27221236
PURPOSE: Cortical bone mechanical properties are related to the collagen-bound water (CBW) and pore water (PW) components of cortical bone. The study evaluates the feasibility of zero-echo-time imaging in mice in vivo for longitudinal relaxation time (T1) measurements in cortical bone and separation of CBW and PW components. METHODS: Zero-echo-time data were acquired at 4.7 Tesla in six mice with 14 different inversion times (0-2,600 ms). Region-of-interest analysis was performed at level of femur diaphysis. The T1 of cortical bone and of CBW (T1cbw) and PW (T1pw) as well as the CBW fraction (cbwf) was computed using a mono-exponential and a bi-exponential fitting approach, respectively. The sum of the squared residuals (Res) to the fit was provided for both approaches. RESULTS: For the mono-exponential model, mean T1 ± standard deviation (SD) was 1,057 ± 160 ms. The bi-exponential approach provided a reliable separation of two different bone-water components, with a mean T1cbw of 213 ± 95 ms, T1pw of 2,152 ± 894 ms, and cbwf of 7.4 ± 2.7 %. Lower Res was obtained with bi-exponential approach (P < 0.001), and Res mean values ± SD were 0.016 ± 0.007 (bi-exponential) and 0.033 ± 0.016 (mono-exponential). CONCLUSION: Zero-echo-time imaging allows for longitudinal relaxation measurements of cortical bone in vivo in mice models, with a reliable separation of PW and CBW components using a bi-exponential curve fitting approach. Magn Reson Med 77:1909-1915, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Huesos / Imagen por Resonancia Magnética / Colágeno Tipo de estudio: Risk_factors_studies Límite: Animals Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2017 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Huesos / Imagen por Resonancia Magnética / Colágeno Tipo de estudio: Risk_factors_studies Límite: Animals Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2017 Tipo del documento: Article País de afiliación: Suiza