Your browser doesn't support javascript.
loading
Charged derivatization and on-line solid phase extraction to measure extremely low cortisol and cortisone levels in human saliva with liquid chromatography-tandem mass spectrometry.
Magda, Balázs; Dobi, Zoltán; Mészáros, Katalin; Szabó, Éva; Márta, Zoltán; Imre, Tímea; Szabó, Pál T.
Afiliación
  • Magda B; MS Metabolomics Laboratory, Core Facility, Research Centre for Natural Sciences, Hungarian Academy of Sciences (IOC RCNS HAS), H-1117 Budapest, Magyar Tudósok Blvd 2, Hungary.
  • Dobi Z; Institute of Organic Chemistry, Research Centre for Natural Sciences, Hungarian Academy of Sciences (IOC RCNS HAS), H-1117 Budapest, Magyar Tudósok Blvd 2, Hungary.
  • Mészáros K; Department of Laboratory Medicine, Semmelweis University, Budapest, Hungary; "Lendület" Hereditary Endocrine Tumours Research Group, HAS-SE, Budapest, Hungary.
  • Szabó É; Egis Pharmaceuticals PLC, H-1106 Budapest, Keresztúri Street 30-38, Hungary.
  • Márta Z; MS Metabolomics Laboratory, Core Facility, Research Centre for Natural Sciences, Hungarian Academy of Sciences (IOC RCNS HAS), H-1117 Budapest, Magyar Tudósok Blvd 2, Hungary.
  • Imre T; MS Metabolomics Laboratory, Core Facility, Research Centre for Natural Sciences, Hungarian Academy of Sciences (IOC RCNS HAS), H-1117 Budapest, Magyar Tudósok Blvd 2, Hungary.
  • Szabó PT; MS Metabolomics Laboratory, Core Facility, Research Centre for Natural Sciences, Hungarian Academy of Sciences (IOC RCNS HAS), H-1117 Budapest, Magyar Tudósok Blvd 2, Hungary. Electronic address: szabo.pal@ttk.mta.hu.
J Pharm Biomed Anal ; 140: 223-231, 2017 Jun 05.
Article en En | MEDLINE | ID: mdl-28365516
The aim of this study was to develop a sensitive, reliable and high-throughput liquid chromatography - electrospray ionization - mass spectrometric (LC-ESI-MS/MS) method for the simultaneous quantitation of cortisol and cortisone in human saliva. Derivatization with 2-hydrazino-1-methylpyridine (HMP) was one of the most challenging aspects of the method development. The reagent was reacting with cortisol and cortisone at 60°C within 1h, giving mono- and bis-hydrazone derivatives. Investigation of derivatization reaction and sample preparation was detailed and discussed. Improvement of method sensitivity was achieved with charged derivatization and use of on-line solid phase extraction (on-line SPE). The lower limit of quantitation (LLOQ) was 5 and 10pg/ml for cortisol and cortisone, respectively. The developed method was subsequently applied to clinical laboratory measurement of cortisol and cortisone in human saliva.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Extracción en Fase Sólida Límite: Humans Idioma: En Revista: J Pharm Biomed Anal Año: 2017 Tipo del documento: Article País de afiliación: Hungria

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Extracción en Fase Sólida Límite: Humans Idioma: En Revista: J Pharm Biomed Anal Año: 2017 Tipo del documento: Article País de afiliación: Hungria