Your browser doesn't support javascript.
loading
Analytic Response Curves of Clinical Breast Cancer IHC Tests.
Vani, Kodela; Sompuram, Seshi R; Schaedle, Anika K; Balasubramanian, Anuradha; Bogen, Steven A.
Afiliación
  • Vani K; Medical Discovery Partners LLC, Boston, Massachusetts (KV, SRS, AKS, AB, SAB), and Department of Pathology and Laboratory Medicine, Tufts Medical Center, Boston, Massachusetts (SAB).
  • Sompuram SR; Medical Discovery Partners LLC, Boston, Massachusetts (KV, SRS, AKS, AB, SAB), and Department of Pathology and Laboratory Medicine, Tufts Medical Center, Boston, Massachusetts (SAB).
  • Schaedle AK; Medical Discovery Partners LLC, Boston, Massachusetts (KV, SRS, AKS, AB, SAB), and Department of Pathology and Laboratory Medicine, Tufts Medical Center, Boston, Massachusetts (SAB).
  • Balasubramanian A; Medical Discovery Partners LLC, Boston, Massachusetts (KV, SRS, AKS, AB, SAB), and Department of Pathology and Laboratory Medicine, Tufts Medical Center, Boston, Massachusetts (SAB).
  • Bogen SA; Medical Discovery Partners LLC, Boston, Massachusetts (KV, SRS, AKS, AB, SAB), and Department of Pathology and Laboratory Medicine, Tufts Medical Center, Boston, Massachusetts (SAB).
J Histochem Cytochem ; 65(5): 273-283, 2017 05.
Article en En | MEDLINE | ID: mdl-28438091
ABSTRACT
An important limitation in the field of immunohistochemistry (IHC) is the inability to correlate stain intensity with specific analyte concentrations. Clinical immunohistochemical tests are not described in terms of analytic response curves, namely, the analyte concentrations in a tissue sample at which an immunohistochemical stain (1) is first visible, (2) increases in proportion to the analyte concentration, and (3) ultimately approaches a maximum color intensity. Using a new immunostaining tool ( IHControls), we measured the analytic response curves of the major clinical immunohistochemical tests for human epidermal growth factor receptor type II (HER-2), estrogen receptor (ER), and progesterone receptor (PR). The IHControls comprise the analytes HER-2, ER, and PR at approximately log concentration intervals across the range of biological expression, from 100 to 1,000,000 molecules per test microbead. We stained IHControls of various concentrations using instruments, reagents, and protocols from three major IHC vendors. Stain intensity at each analyte concentration was measured, thereby generating an analytic response curve. We learned that for HER-2 and PR, there is significant variability in test results between clinical kits for samples with analyte concentrations of approximately 104 molecules/microbead. We propose that the characterization of immunostains is an important step toward standardization.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Receptores de Progesterona / Receptores de Estrógenos / Receptor ErbB-2 Tipo de estudio: Guideline Límite: Female / Humans Idioma: En Revista: J Histochem Cytochem Asunto de la revista: HISTOCITOQUIMICA Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Receptores de Progesterona / Receptores de Estrógenos / Receptor ErbB-2 Tipo de estudio: Guideline Límite: Female / Humans Idioma: En Revista: J Histochem Cytochem Asunto de la revista: HISTOCITOQUIMICA Año: 2017 Tipo del documento: Article