Your browser doesn't support javascript.
loading
The Precision of Hepatic Arterial Infusion Scintigraphy as a Quantitative Biomarker of Tumor Microvasculature.
Dunphy, Mark; Pandit-Taskar, Neeta; Fox, Josef J; Kemeny, Nancy.
Afiliación
  • Dunphy M; 1 Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY 10065.
  • Pandit-Taskar N; 1 Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY 10065.
  • Fox JJ; 1 Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Ave, New York, NY 10065.
  • Kemeny N; 2 Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY.
AJR Am J Roentgenol ; 209(1): 182-186, 2017 Jul.
Article en En | MEDLINE | ID: mdl-28537788
ABSTRACT

OBJECTIVE:

Optimal clinical development of new cancer therapies targeting tumor vasculature requires new target-specific response assays. This clinical study examined the test-retest repeatability of SPECT as an in vivo assay of angiogenic hepatic tumor microvasculature using an intraarterial infusion of 99mTc-macroaggregated albumin (MAA) delivered via a hepatic artery infusion (HAI) pump. MATERIALS AND

METHODS:

Patients with primary or secondary cancerous liver tumors with HAI pump-catheter implants placed for HAI chemotherapy underwent hepatic SPECT after separate arterial infusions of 37 and 185 MBq of 99mTc-MAA via an HAI pump. Quantitative measures of hepatic tumor MAA uptake were obtained from paired test-retest SPECT datasets. Repeatability was defined by quotients of paired measurands with 95% CIs and coefficients of repeatability (CRs).

RESULTS:

Test-retest HAI pump SPECT yielded highly repeatable measurements in quantitative indexes of tumor microvasculature. Variability in repeat test-retest measurements was small relative to the range of observed measurements between different tumors. The total hepatic tumor microvascular MAA accumulation (percentage injected dose) proved most repeatable, with test-retest value quotients near unity (quotients median, 1.10 ± 0.09 [SD]; range, 1.03-1.32; 95% CI, 1.07-1.19) and 1.6% CR. Tumor MAA uptake values ranged from 5% to 18% injected dose.

CONCLUSION:

This article describes the precision of HAI SPECT as a quantitative biomarker of tumor microvasculature under conditions of repeatability. The results support clinical testing of HAI SPECT as a radiologic response biomarker for angiotropic tumor therapy.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tomografía Computarizada de Emisión de Fotón Único / Agregado de Albúmina Marcado con Tecnecio Tc 99m / Radiofármacos / Inhibidores de la Angiogénesis / Arteria Hepática / Neoplasias Hepáticas / Neovascularización Patológica Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: AJR Am J Roentgenol Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tomografía Computarizada de Emisión de Fotón Único / Agregado de Albúmina Marcado con Tecnecio Tc 99m / Radiofármacos / Inhibidores de la Angiogénesis / Arteria Hepática / Neoplasias Hepáticas / Neovascularización Patológica Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: AJR Am J Roentgenol Año: 2017 Tipo del documento: Article