Your browser doesn't support javascript.
loading
Direct percutaneous endoscopic jejunostomy using single-balloon enteroscopy without fluoroscopy: a case series.
Bernardes, Carlos; Pinho, Rolando; Rodrigues, Adélia; Proença, Luísa; Carvalho, João.
Afiliación
  • Bernardes C; Department of Gastroenterology, Centro Hospitalar de Lisboa Central, Portugal.
  • Pinho R; Department of Gastroenterology and Hepatology, Centro Hospitalar de Vila Nova de Gaia/Espinho, Portugal.
  • Rodrigues A; Department of Gastroenterology and Hepatology, Centro Hospitalar de Gaia/Espinho, Portugal.
  • Proença L; Department of Gastroenterology and Hepatology, Centro Hospitalar de Vila Nova de Gaia/Espinho, Portugal.
  • Carvalho J; Department of Gastroenterology and Hepatology, Centro Hospitalar de Vila Nova de Gaia/Espinho.
Rev Esp Enferm Dig ; 109(10): 679-683, 2017 Oct.
Article en En | MEDLINE | ID: mdl-28724303
ABSTRACT

BACKGROUND:

Direct percutaneous endoscopic jejunostomy (DPEJ) is a useful method to provide enteral nutrition to individuals when gastric feeding is not possible or contraindicated. The aim of this study was to analyze the efficacy and safety of DPEJ tube placement with the Gauderer-Ponsky technique by the pull method, using single-balloon enteroscopy (SBE) without fluoroscopy.

METHODS:

This is a retrospective analysis of patients undergoing SBE for DPEJ placement in a referral hospital between January 2010 and March 2016. Technical success, clinical success and procedure related complications were recorded.

RESULTS:

Twenty-three patients were included (17 males, median age 71 years, range 37-93 years). The most frequent indications for DPEJ were gastroesophageal cancer (n = 10) and neurological disease (n = 8). Eighty-seven percent of the patients had a contraindication to percutaneous endoscopic gastrostomy (PEG) and PEG was unsuccessful in the remaining patients. The technical success rate was 83% (19/23), transillumination was not possible in three patients and an accidental exteriorization of the bumper resulting in a jejunal perforation occurred in one patient. The clinical success was 100% (19/19). The median follow-up was five months (range 1-35 months). Apart from the case of jejunal perforation and the two cases of accidental exteriorization, there were no other complications during follow-up. The 6-month survival was 65.8% and the 1-year survival was 49.3%.

CONCLUSION:

DPEJ can be carried out successfully via SBE without fluoroscopy with a low rate of significant adverse events. Although, leaving the overtube in place during the bumper pulling can be useful for distal jejunal loops, it can be safely removed in proximal loops to minimize complications.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Yeyunostomía / Enteroscopia de Balón Individual Tipo de estudio: Observational_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Rev Esp Enferm Dig Asunto de la revista: GASTROENTEROLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Portugal

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Yeyunostomía / Enteroscopia de Balón Individual Tipo de estudio: Observational_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Rev Esp Enferm Dig Asunto de la revista: GASTROENTEROLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Portugal