Your browser doesn't support javascript.
loading
The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs.
Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin.
Afiliación
  • Huang Z; Department of Orthopaedics, The 1st Affiliated Hospital of Sun Yat-sen University, NO.58, Zhongshan Er Road, Guangzhou, Guangdong, China.
  • Wang C; Department of Orthopaedics, The 1st Affiliated Hospital of Sun Yat-sen University, NO.58, Zhongshan Er Road, Guangzhou, Guangdong, China.
  • Fan H; Department of Orthopaedics, The 1st Affiliated Hospital of Sun Yat-sen University, NO.58, Zhongshan Er Road, Guangzhou, Guangdong, China.
  • Sui W; Department of Orthopaedics, The 1st Affiliated Hospital of Sun Yat-sen University, NO.58, Zhongshan Er Road, Guangzhou, Guangdong, China.
  • Li X; Department of Orthopaedics, The 1st Affiliated Hospital of Sun Yat-sen University, NO.58, Zhongshan Er Road, Guangzhou, Guangdong, China.
  • Wang Q; Department of Orthopaedics, The 1st Affiliated Hospital of Sun Yat-sen University, NO.58, Zhongshan Er Road, Guangzhou, Guangdong, China.
  • Yang J; Department of Orthopaedics, The 1st Affiliated Hospital of Sun Yat-sen University, NO.58, Zhongshan Er Road, Guangzhou, Guangdong, China. yjunlin@126.com.
BMC Musculoskelet Disord ; 18(1): 322, 2017 Jul 28.
Article en En | MEDLINE | ID: mdl-28754114
ABSTRACT

BACKGROUND:

Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque.

METHODS:

Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs.

RESULTS:

The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively.

CONCLUSIONS:

The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Escoliosis / Tornillos Óseos / Procedimientos Ortopédicos Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2017 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Escoliosis / Tornillos Óseos / Procedimientos Ortopédicos Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2017 Tipo del documento: Article País de afiliación: China