Your browser doesn't support javascript.
loading
Hemin as electrochemically regenerable co-reaction accelerator for construction of an ultrasensitive PTCA-based electrochemiluminescent aptasensor.
Zeng, Wei-Jia; Liao, Ni; Lei, Yan-Mei; Zhao, Jing; Chai, Ya-Qin; Yuan, Ruo; Zhuo, Ying.
Afiliación
  • Zeng WJ; Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
  • Liao N; Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China; College of Biological and Chemical Engineering, Panzhihua University, Panzhihua 617000, China.
  • Lei YM; Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
  • Zhao J; Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
  • Chai YQ; Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
  • Yuan R; Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China. Electronic address: yuanruo@swu.edu.cn.
  • Zhuo Y; Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China. Electronic address: yingzhuo@swu.edu.cn.
Biosens Bioelectron ; 100: 490-496, 2018 Feb 15.
Article en En | MEDLINE | ID: mdl-28965054
ABSTRACT
In this work, hemin was firstly used as electrochemically regenerable co-reaction accelerator for signal amplification to develop an ultrasensitive aptasensor for Aflatoxin M1 (AFM1) detection. Initially, the perylenetetracarboxylic acid (PTCA) was directly employed as luminophore to construct the ECL sensing nano-platform by combining Au nanoparticles (Au NPs) for immobilizing thiol-terminated hairpin probe (H1). Then with the help of hairpin H2, H3, the AFM1-catalyzed hairpin assembly (CHA) was executed to produce the H1-H3 duplex, which could further initiate the hybridization chain reaction (HCR) to generate dendritic DNA polymers consisting of G-rich sequence for capturing large quantities of hemin on the electrode surface. Herein, hemin as electrochemically regenerable co-reaction accelerator could interact with the co-reactant (S2O82-) to obviously improve the luminous efficiency of the PTCA. Therefore, a strong and stable ECL signal was achieved by the employment of hemin as electrochemically regenerable co-reaction accelerator. The proposed aptasensor determined AFM1 down to 0.09pgmL-1 within a linear range of 0.4pgmL-1 to 400ngmL-1. With excellent sensitivity and stability, the strategy provided an efficient and simple method for the trace detection of biomolecules in clinical analysis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Perileno / Técnicas Biosensibles / Aflatoxina M1 / Sustancias Luminiscentes / Aptámeros de Nucleótidos / Hemina Tipo de estudio: Evaluation_studies Límite: Animals Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Perileno / Técnicas Biosensibles / Aflatoxina M1 / Sustancias Luminiscentes / Aptámeros de Nucleótidos / Hemina Tipo de estudio: Evaluation_studies Límite: Animals Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: China