Your browser doesn't support javascript.
loading
A microfluidic in-line ELISA for measuring secreted protein under perfusion.
Luan, Qiyue; Cahoon, Stacey; Wu, Agnes; Bale, Shyam Sundhar; Yarmush, Martin; Bhushan, Abhinav.
Afiliación
  • Luan Q; Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, 60616, USA.
  • Cahoon S; Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, 60616, USA.
  • Wu A; Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, 60616, USA.
  • Bale SS; Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA.
  • Yarmush M; Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA.
  • Bhushan A; Department of Biomedical Engineering, Rutgers University, Piscataway, NJ, 08854, USA.
Biomed Microdevices ; 19(4): 101, 2017 Nov 11.
Article en En | MEDLINE | ID: mdl-29128921
ABSTRACT
Recent progress in the development of microfluidic microphysiological systems such as 'organs-on-chips' and microfabricated cell culture is geared to simulate organ-level physiology. These tissue models leverage microengineering technologies that provide capabilities of presenting cultured cells with input signals in a more physiologically relevant context such as perfused flow. Proteins that are secreted from cells have important information about the health of the cells. Techniques to quantify cellular proteins include mass spectrometry to ELISA (enzyme-linked immunosorbent assay). Although our capability to perturb the cells in the microphysiological systems with varying inputs is well established, we lack the tools to monitor in-line the cellular responses. User intervention for sample collection and off-site is cumbersome, causes delays in obtaining results, and is especially expensive because of collection, storage, and offline processing of the samples, and in many case, technically impractical to carry out because of limitated sample volumes. To address these shortcomings, we report the development of an ELISA that is carried out in-line under perfusion within a microfluidic device. Using this assay, we measured the albumin secreted from perfused hepatocytes without and under stimulation by IL-6. Since the method is based on a sandwich ELISA, we envision broad application of this technology to not just organs-on-chips but also to characterizing the temporal release and measurement of soluble factors and response to drugs.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Ensayo de Inmunoadsorción Enzimática / Albúminas / Dispositivos Laboratorio en un Chip Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Biomed Microdevices Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Ensayo de Inmunoadsorción Enzimática / Albúminas / Dispositivos Laboratorio en un Chip Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Biomed Microdevices Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos