Your browser doesn't support javascript.
loading
Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data.
Lu, Yihuan; Fontaine, Kathryn; Mulnix, Tim; Onofrey, John A; Ren, Silin; Panin, Vladimir; Jones, Judson; Casey, Michael E; Barnett, Robert; Kench, Peter; Fulton, Roger; Carson, Richard E; Liu, Chi.
Afiliación
  • Lu Y; Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut yihuan.lu@yale.edu.
  • Fontaine K; Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut.
  • Mulnix T; Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut.
  • Onofrey JA; Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut.
  • Ren S; Department of Biomedical Engineering, Yale University, New Haven, Connecticut.
  • Panin V; Siemens Medical Solutions, Knoxville, Tennessee; and.
  • Jones J; Siemens Medical Solutions, Knoxville, Tennessee; and.
  • Casey ME; Siemens Medical Solutions, Knoxville, Tennessee; and.
  • Barnett R; Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, Sydney, Australia.
  • Kench P; Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, Sydney, Australia.
  • Fulton R; Discipline of Medical Radiation Sciences, Faculty of Health Sciences, University of Sydney, Sydney, Australia.
  • Carson RE; Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut.
  • Liu C; Department of Biomedical Engineering, Yale University, New Haven, Connecticut.
J Nucl Med ; 59(9): 1480-1486, 2018 09.
Article en En | MEDLINE | ID: mdl-29439015
ABSTRACT
Respiratory motion degrades the detection and quantification capabilities of PET/CT imaging. Moreover, mismatch between a fast helical CT image and a time-averaged PET image due to respiratory motion results in additional attenuation correction artifacts and inaccurate localization. Current motion compensation approaches typically have 3

limitations:

the mismatch among respiration-gated PET images and the CT attenuation correction (CTAC) map can introduce artifacts in the gated PET reconstructions that can subsequently affect the accuracy of the motion estimation; sinogram-based correction approaches do not correct for intragate motion due to intracycle and intercycle breathing variations; and the mismatch between the PET motion compensation reference gate and the CT image can cause an additional CT-mismatch artifact. In this study, we established a motion correction framework to address these limitations.

Methods:

In the proposed framework, the combined emission-transmission reconstruction algorithm was used for phase-matched gated PET reconstructions to facilitate the motion model building. An event-by-event nonrigid respiratory motion compensation method with correlations between internal organ motion and external respiratory signals was used to correct both intracycle and intercycle breathing variations. The PET reference gate was automatically determined by a newly proposed CT-matching algorithm. We applied the new framework to 13 human datasets with 3 different radiotracers and 323 lesions and compared its performance with CTAC and non-attenuation correction (NAC) approaches. Validation using 4-dimensional CT was performed for one lung cancer dataset.

Results:

For the 10 18F-FDG studies, the proposed method outperformed (P < 0.006) both the CTAC and the NAC methods in terms of region-of-interest-based SUVmean, SUVmax, and SUV ratio improvements over no motion correction (SUVmean 19.9% vs. 14.0% vs. 13.2%; SUVmax 15.5% vs. 10.8% vs. 10.6%; SUV ratio 24.1% vs. 17.6% vs. 16.2%, for the proposed, CTAC, and NAC methods, respectively). The proposed method increased SUV ratios over no motion correction for 94.4% of lesions, compared with 84.8% and 86.4% using the CTAC and NAC methods, respectively. For the 2 18F-fluoropropyl-(+)-dihydrotetrabenazine studies, the proposed method reduced the CT-mismatch artifacts in the lower lung where the CTAC approach failed and maintained the quantification accuracy of bone marrow where the NAC approach failed. For the 18F-FMISO study, the proposed method outperformed both the CTAC and the NAC methods in terms of motion estimation accuracy at 2 lung lesion locations.

Conclusion:

The proposed PET/CT respiratory event-by-event motion-correction framework with motion information derived from matched attenuation-corrected PET data provides image quality superior to that of the CTAC and NAC methods for multiple tracers.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Respiración / Procesamiento de Imagen Asistido por Computador / Artefactos / Técnicas de Imagen Sincronizada Respiratorias / Tomografía Computarizada por Tomografía de Emisión de Positrones / Movimiento Límite: Humans Idioma: En Revista: J Nucl Med Año: 2018 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Respiración / Procesamiento de Imagen Asistido por Computador / Artefactos / Técnicas de Imagen Sincronizada Respiratorias / Tomografía Computarizada por Tomografía de Emisión de Positrones / Movimiento Límite: Humans Idioma: En Revista: J Nucl Med Año: 2018 Tipo del documento: Article