Your browser doesn't support javascript.
loading
Absolute quantitation of acetaminophen-modified human serum albumin in acute liver failure patients by liquid chromatography/tandem mass spectrometry.
Geib, Timon; LeBlanc, André; Shiao, Tze Chieh; Roy, René; Leslie, Elaine M; Karvellas, Constantine J; Sleno, Lekha.
Afiliación
  • Geib T; Chemistry Department/Pharmaqam, Université du Québec à Montréal, Montréal, QC, Canada.
  • LeBlanc A; Chemistry Department/Pharmaqam, Université du Québec à Montréal, Montréal, QC, Canada.
  • Shiao TC; Chemistry Department/Pharmaqam, Université du Québec à Montréal, Montréal, QC, Canada.
  • Roy R; Chemistry Department/Pharmaqam, Université du Québec à Montréal, Montréal, QC, Canada.
  • Leslie EM; Department of Physiology, University of Alberta, Edmonton, AB, Canada.
  • Karvellas CJ; Department of Critical Care Medicine and Gastroenterology/Hepatology, University of Alberta, Edmonton, AB, Canada.
  • Sleno L; Chemistry Department/Pharmaqam, Université du Québec à Montréal, Montréal, QC, Canada.
Rapid Commun Mass Spectrom ; 32(17): 1573-1582, 2018 Sep 15.
Article en En | MEDLINE | ID: mdl-29920820
RATIONALE: Acetaminophen (APAP) is a well-known analgesic, deemed a very safe over-the-counter medication. However, it is also the main cause of acute liver failure (ALF) in the Western world, via the formation of its reactive metabolite, N-acetyl p-benzoquinone imine (NAPQI), and its covalent attachment to liver proteins. The aim of this study was to develop a sensitive and robust quantitative assay to monitor APAP-protein binding to human serum albumin (HSA) in patient samples. METHODS: A combination of isotope dilution, peptic digestion and solid-phase extraction coupled to liquid chromatography/multiple reaction monitoring (LC/MRM) was employed. An external calibration curve with surrogate modified protein spiked into blank serum was used for absolute quantitation. Samples were analyzed by LC/MRM to measure the modified active site peptide of HSA. The LC/MRM assay was validated and successfully applied to serum samples from patients suffering from APAP-induced ALF. RESULTS: Accuracy ranged from 83.8-113.3%, within-run coefficient of variation (CV) ranged from 0.3-6.9%, and total CVs from 1.6-10.6%. Patient samples ranged from 0.12-3.91 nmol/mL NAPQI-HSA; in-between the assay dynamic range of 0.11-50.13 nmol/mL serum. In vivo median concentrations were found to be 0.62 nmol/mL and 0.91 nmol/mL for non-spontaneous survivors (n = 25) and individuals with irreversible liver damage (n = 10), respectively (p-value = 0.028), demonstrating significant potential as a biomarker for ALF outcome. CONCLUSIONS: A fast and sensitive assay was developed to accurately quantify NAPQI-HSA as a biomarker for APAP-related covalent binding in human serum.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cromatografía Liquida / Fallo Hepático Agudo / Espectrometría de Masas en Tándem / Albúmina Sérica Humana / Acetaminofén Tipo de estudio: Etiology_studies / Evaluation_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Rapid Commun Mass Spectrom Año: 2018 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cromatografía Liquida / Fallo Hepático Agudo / Espectrometría de Masas en Tándem / Albúmina Sérica Humana / Acetaminofén Tipo de estudio: Etiology_studies / Evaluation_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Rapid Commun Mass Spectrom Año: 2018 Tipo del documento: Article País de afiliación: Canadá