Influence of polymerization time on properties of dual-curing cements in combination with high translucency monolithic zirconia.
Alovisi, Mario; Scotti, Nicola; Comba, Allegra; Manzon, Elena; Farina, Elena; Pasqualini, Damiano; Michelotto Tempesta, Riccardo; Breschi, Lorenzo; Cadenaro, Milena.
Afiliación
  • Alovisi M; Department of Surgical Sciences, University of Turin, Turin, Italy.
  • Scotti N; Department of Surgical Sciences, University of Turin, Turin, Italy; School of Nanotechnology, University of Trieste, Trieste, Italy. Electronic address: nicola.scotti@unito.it.
  • Comba A; Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy.
  • Manzon E; School of Nanotechnology, University of Trieste, Trieste, Italy.
  • Farina E; Department of Epidemiology, ASL To3 Grugliasco, Turin, Italy; Associate Professor, Department of Surgical Sciences, Dental School, Turin, Italy.
  • Pasqualini D; School of Nanotechnology, University of Trieste, Trieste, Italy.
  • Michelotto Tempesta R; School of Nanotechnology, University of Trieste, Trieste, Italy.
  • Breschi L; Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy.
  • Cadenaro M; Department of Medical Sciences, University of Trieste, Trieste, Italy; IRCCS Burlo Garofolo, Trieste, Italy.
J Prosthodont Res ; 62(4): 468-472, 2018 Oct.
Article en En | MEDLINE | ID: mdl-29983378
ABSTRACT

PURPOSE:

The aim of this in vitro study was to assess conversion degree (DC), micro-hardness (MH) and bond strength of two dual-curing resin cements employed under translucent monolithic zirconia irradiated with different time protocols.

METHODS:

84 square shaped samples of 1mm thickness were prepared from high translucency zirconia blocks and divided into two groups (n=24) according to the cement employed (1) Rely-X Ultimate; (2) Panavia SA. Each group was further divided into 3 subgroups (n=8) according to the irradiation time (a) no light; (b) 20s; (c) 120s. Light curing was performed 60s after the sample was placed on the diamond support of a FT-IR spectrophotometer with a high power multiLED lamp. Final DC% were calculated after 10min. After 24h, Vickers Test on the cement layer was performed. The same protocol was used to lute composite cylinders in order to evaluate microshear bond-strength test. ANOVA and Bonferroni tests were performed to find differences between MH and bond-strength to zirconia, while for DC% the Scheirer-Ray-Hare two-way test was used.

RESULTS:

The two cements reached higher DC% in subgroup (b) and (c). As concern MH, statistics showed an increase in curing time was able to improve MH significantly. Bond-strength was not affected by irradiation time only for Panavia SA.

CONCLUSIONS:

The first null hypothesis has to be rejected since DC% and MH of the dual-cements tested were influenced by the curing time. The second null hypothesis is partially rejected since the bond strength was influenced by the curing time only for Rely-X Ultimate.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Resinas Sintéticas / Circonio / Recubrimiento Dental Adhesivo / Resinas Compuestas / Cementos Dentales / Polimerizacion / Lansoprazol Idioma: En Revista: J Prosthodont Res Asunto de la revista: ODONTOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Resinas Sintéticas / Circonio / Recubrimiento Dental Adhesivo / Resinas Compuestas / Cementos Dentales / Polimerizacion / Lansoprazol Idioma: En Revista: J Prosthodont Res Asunto de la revista: ODONTOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Italia