Your browser doesn't support javascript.
loading
Tethered capsule endomicroscopy for microscopic imaging of the esophagus, stomach, and duodenum without sedation in humans (with video).
Gora, Michalina J; Quénéhervé, Lucille; Carruth, Robert W; Lu, Weina; Rosenberg, Mireille; Sauk, Jenny S; Fasano, Alessio; Lauwers, Gregory Y; Nishioka, Norman S; Tearney, Guillermo J.
Afiliación
  • Gora MJ; ICube Laboratory, CNRS, Strasbourg University, Strasbourg, France; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Quénéhervé L; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA; Institut des Maladies de l'Appareil Digestif, IMAD, CHU Nantes, Hopital Hôtel-Dieu, Nantes, France.
  • Carruth RW; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Lu W; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Rosenberg M; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA; Harvard Medical School, Boston, Massachusetts, USA.
  • Sauk JS; Department of Gastroenterology, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Fasano A; Department of Pediatrics, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Lauwers GY; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Nishioka NS; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA; Department of Gastroenterology, Massachusetts General Hospital, Boston, Massachusetts, USA; Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Tearney GJ; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA; Harvard Medical School, Boston, Massachusetts, USA; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts, USA; Department of Medicine, Massachusetts General Hospital, Boston, Massa
Gastrointest Endosc ; 88(5): 830-840.e3, 2018 11.
Article en En | MEDLINE | ID: mdl-30031805
BACKGROUND AND AIMS: Patients with many different digestive diseases undergo repeated EGDs throughout their lives. Tethered capsule endomicroscopy (TCE) is a less-invasive method for obtaining high-resolution images of the GI mucosa for diagnosis and treatment planning of GI tract diseases. In this article, we present our results from a single-center study aimed at testing the safety and feasibility of TCE for imaging the esophagus, stomach, and duodenum. METHODS: After being swallowed by a participant without sedation, the tethered capsule obtains cross-sectional, 10 µm-resolution, optical coherence tomography images as the device traverses the alimentary tract. After imaging, the device is withdrawn through the mouth, disinfected, and reused. Safety and feasibility of TCE were tested, focusing on imaging the esophagus of healthy volunteers and patients with Barrett's esophagus (BE) and the duodenum of healthy volunteers. Images were compared with endoscopy and histopathology findings when available. RESULTS: Thirty-eight patients were enrolled. No adverse effects were reported. The TCE device swallowing rate was 34 of 38 (89%). The appearance of a physiologic upper GI wall, including its microscopic pathology, was visualized with a tissue coverage of 85.4% ± 14.9% and 90.3% ± 6.8% in the esophagus of BE patients with and without endoscopic evidence of a hiatal hernia, respectively, as well as 84.8% ± 7.4% in the duodenum. A blinded comparison of TCE and endoscopic BE measurements showed a strong to very strong correlation (r = 0.7-0.83; P < .05) for circumferential extent and a strong correlation (r = 0.77-0.78; P < .01) for maximum extent (Prague classification). TCE interobserver correlation was very strong, at r = 0.92 and r = 0.84 (P < .01), for Prague classification circumferential (C) and maximal (M) length measurements, respectively. CONCLUSIONS: TCE is a safe and feasible procedure for obtaining high-resolution microscopic images of the upper GI tract without endoscopic assistance or sedation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tracto Gastrointestinal Superior / Tomografía de Coherencia Óptica / Endoscopía Capsular Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Gastrointest Endosc Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tracto Gastrointestinal Superior / Tomografía de Coherencia Óptica / Endoscopía Capsular Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Gastrointest Endosc Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos