Your browser doesn't support javascript.
loading
Optic disc microvasculature dropout in primary open-angle glaucoma measured with optical coherence tomography angiography.
Akagi, Tadamichi; Zangwill, Linda M; Shoji, Takuhei; Suh, Min Hee; Saunders, Luke J; Yarmohammadi, Adeleh; Manalastas, Patricia Isabel C; Penteado, Rafaella C; Weinreb, Robert N.
Afiliación
  • Akagi T; Hamilton Glaucoma Center, Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, United States of America.
  • Zangwill LM; Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan.
  • Shoji T; Hamilton Glaucoma Center, Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, United States of America.
  • Suh MH; Hamilton Glaucoma Center, Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, United States of America.
  • Saunders LJ; Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
  • Yarmohammadi A; Hamilton Glaucoma Center, Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, United States of America.
  • Manalastas PIC; Department of Ophthalmology, Haeundae Paik Hospital, Inje University, Busan, South Korea.
  • Penteado RC; Hamilton Glaucoma Center, Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, United States of America.
  • Weinreb RN; Hamilton Glaucoma Center, Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, United States of America.
PLoS One ; 13(8): e0201729, 2018.
Article en En | MEDLINE | ID: mdl-30086177
PURPOSE: To evaluate microvasculature dropout in the optic disc (Mvd-D) using optical coherence tomography angiography (OCTA) and investigate factors associated with Mvd-D in primary open-angle glaucoma (POAG) eyes. METHODS: One hundred twenty-three eyes of 123 POAG patients were included from the Diagnostic Innovations in Glaucoma Study. The 3.0×3.0-mm optic nerve head OCTA scans were acquired using a spectral-domain OCT instrument. Images with whole-signal-mode were evaluated. Eyes were classified into 3 categories (Mvd-D, pseudo-Mvd-D, and no Mvd-D). Mvd-D and pseudo-Mvd-D had complete loss of OCTA signals on the temporal side of the optic disc on the en face projection image. They were distinguished base on the visualization of the anterior lamina cribrosa in the horizontal B-scans of that area. No Mvd-D was defined when no complete signal loss of OCTA signals was observed. Covariates including focal lamina cribrosa defects assessed by swept-source OCT and microvasculature dropout in the parapapillary region (Mvd-P) were analyzed. RESULTS: Forty-two, 37, and 44 eyes were identified as having Mvd-D, pseudo-Mvd-D, and no Mvd-D, respectively. The eyes with Mvd-D showed significantly lower intraocular pressure, worse visual field mean deviation, larger cup-to-disc ratio, thinner circumpapillary retinal nerve fiber layer (cpRNFL), and lower circumpapillary vessel density within the RNFL than the eyes with pseudo-Mvd-D or the eyes without Mvd-D. Multivariable logistic regression analysis showed significant associations of Mvd-D with larger cup-to-disc ratio (OR, 1.08; P = 0.001), worse visual field mean deviation (OR, 1.09; P = 0.048), higher prevalence of focal lamina cribrosa defect (OR, 9.05; P = 0.002), and higher prevalence of Mvd-P (OR, 10.33; P <0.001). CONCLUSIONS: OCTA-derived Mvd-D was strongly associated with the presences of Mvd-P and focal lamina cribrosa defects, and these 3 findings were topographically associated with each other.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Disco Óptico / Angiografía / Glaucoma de Ángulo Abierto / Tomografía de Coherencia Óptica / Microvasos Tipo de estudio: Clinical_trials / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Disco Óptico / Angiografía / Glaucoma de Ángulo Abierto / Tomografía de Coherencia Óptica / Microvasos Tipo de estudio: Clinical_trials / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2018 Tipo del documento: Article País de afiliación: Estados Unidos