Localized surface plasmon resonance biosensor: an improved technique for SERS response intensification.
Opt Lett
; 44(5): 1134-1137, 2019 Mar 01.
Article
en En
| MEDLINE
| ID: mdl-30821731
As technology continues to advance, the development of novel sensing systems opens new possibilities for low-cost, practical biosensing applications. In this Letter, we demonstrate a localized surface plasmon resonance system that combines both wave-guiding and plasmonic resonance sensing with a single microstructured polymeric structure. Characterizing the sensor using the finite element method simulation shows, to the best of our knowledge, a record wavelength sensitivity (WS) of 111000 nm/refractive index unit (RIU), high amplitude sensitivity (AS) of 2050 RIU-1, high sensor resolution and limit of detection of 9×10-7 RIU and 8.12×10-12 RIU2/nm, respectively. Furthermore, these sensors have the capability to detect an analyte within the refractive index range of 1.33-1.43 in the visible to mid-IR, therefore being potentially suitable for applications in biomolecular and chemical analyte detection.
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Resonancia por Plasmón de Superficie
Idioma:
En
Revista:
Opt Lett
Año:
2019
Tipo del documento:
Article