Your browser doesn't support javascript.
loading
Resolving degeneracy in diffusion MRI biophysical model parameter estimation using double diffusion encoding.
Coelho, Santiago; Pozo, Jose M; Jespersen, Sune N; Jones, Derek K; Frangi, Alejandro F.
Afiliación
  • Coelho S; Centre for Computational Imaging & Simulation Technologies in Biomedicine (CISTIB) and Leeds Institute for Cardiac and Metabolic Medicine (LICAMM), School of Computing & School of Medicine, University of Leeds, Leeds, United Kingdom.
  • Pozo JM; CISTIB, Electronic and Electrical Engineering Department, The University of Sheffield, Sheffield, United Kingdom.
  • Jespersen SN; Centre for Computational Imaging & Simulation Technologies in Biomedicine (CISTIB) and Leeds Institute for Cardiac and Metabolic Medicine (LICAMM), School of Computing & School of Medicine, University of Leeds, Leeds, United Kingdom.
  • Jones DK; CISTIB, Electronic and Electrical Engineering Department, The University of Sheffield, Sheffield, United Kingdom.
  • Frangi AF; Center of Functionally Integrative Neuroscience (CFIN) and MINDLab, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
Magn Reson Med ; 82(1): 395-410, 2019 07.
Article en En | MEDLINE | ID: mdl-30865319
ABSTRACT

PURPOSE:

Biophysical tissue models are increasingly used in the interpretation of diffusion MRI (dMRI) data, with the potential to provide specific biomarkers of brain microstructural changes. However, it has been shown recently that, in the general Standard Model, parameter estimation from dMRI data is ill-conditioned even when very high b-values are applied. We analyze this issue for the Neurite Orientation Dispersion and Density Imaging with Diffusivity Assessment (NODDIDA) model and demonstrate that its extension from single diffusion encoding (SDE) to double diffusion encoding (DDE) resolves the ill-posedness for intermediate diffusion weightings, producing an increase in accuracy and precision of the parameter estimation.

METHODS:

We analyze theoretically the cumulant expansion up to fourth order in b of SDE and DDE signals. Additionally, we perform in silico experiments to compare SDE and DDE capabilities under similar noise conditions.

RESULTS:

We prove analytically that DDE provides invariant information non-accessible from SDE, which makes the NODDIDA parameter estimation injective. The in silico experiments show that DDE reduces the bias and mean square error of the estimation along the whole feasible region of 5D model parameter space.

CONCLUSIONS:

DDE adds additional information for estimating the model parameters, unexplored by SDE. We show, as an example, that this is sufficient to solve the previously reported degeneracies in the NODDIDA model parameter estimation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Imagen de Difusión por Resonancia Magnética Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Imagen de Difusión por Resonancia Magnética Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article País de afiliación: Reino Unido