Your browser doesn't support javascript.
loading
Facile synthesis of mesoporous WS2 nanorods decorated N-doped RGO network modified electrode as portable electrochemical sensing platform for sensitive detection of toxic antibiotic in biological and pharmaceutical samples.
Chen, Tse-Wei; Rajaji, Umamaheswari; Chen, Shen-Ming; Chinnapaiyan, Sathiskumar; Ramalingam, R Jothi.
Afiliación
  • Chen TW; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan; Research and Development Center for Smart Textile Technology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road,
  • Rajaji U; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan.
  • Chen SM; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan. Electronic address: smchen78@ms15.hinet.net.
  • Chinnapaiyan S; International Master Program in Mechanical and Automation Engineering, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan.
  • Ramalingam RJ; Surfactant Research Chair, Chemistry Department, College of Science, King Saud University, P.O. Box-2455, Riyadh 11451, Saudi Arabia.
Ultrason Sonochem ; 56: 430-436, 2019 Sep.
Article en En | MEDLINE | ID: mdl-31101281
ABSTRACT
We report a facile and ultrasound assisted sonochemical synthesis of a Tungsten disulfide nanorods decorated nitrogen-doped reduced graphene oxide based nanocomposite. The WS2 NRs/N-rGOs nanocomposite was characterized by FESEM, HRTEM, XRD, XPS and electrochemical methods and its application towards the electrochemical detection of organo-arsenic drug (coccidiostat). The WS2 NRs/N-rGOs modified SPCE was used for the electrochemical reduction of roxarsone (ROX) and it showed superior electrocatalytic performance in terms of reduction peak current and shift in overpotential when compared to those of WS2 NRs/SPCE, N-rGOs/SPCE and based SPCE. The WS2 NRs/N-rGOs modified SPCE showed an excellent sensing ability towards ROX in nitrogen saturated phosphate buffer (PB) then the other controlled modified and unmodified electrodes. The WS2 NRs/N-rGOs/SPCE displays high sensitive response towards ROX and gives wide linearity in the range of 0.1-442.6 µM ROX in neutral phosphate buffer (pH 7.0) and the sensitivity of the sensor is calculated as 14.733 µA µM-1 cm-2. The WS2 NRs/N-rGOs nanocomposite modified sensor also exhibits valuable ability of anti-interference to electroactive analytes. Furthermore, the as-prepared WS2 NRs/N-rGOs/SPCE has been applied to the determination of ROX in biological and pharmaceutical samples.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Roxarsona / Sulfuros / Compuestos de Tungsteno / Nanotubos / Electroquímica / Límite de Detección / Grafito / Antibacterianos / Nitrógeno Tipo de estudio: Diagnostic_studies Idioma: En Revista: Ultrason Sonochem Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Roxarsona / Sulfuros / Compuestos de Tungsteno / Nanotubos / Electroquímica / Límite de Detección / Grafito / Antibacterianos / Nitrógeno Tipo de estudio: Diagnostic_studies Idioma: En Revista: Ultrason Sonochem Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2019 Tipo del documento: Article