Your browser doesn't support javascript.
loading
Clinical evaluation of performance, biocompatibility, and safety of vitamin E-bonded polysulfone membrane hemodialyzer compared to non-vitamin E-bonded hemodialyzer.
Kiaii, Mercedeh; Aritomi, Masaharu; Nagase, Mitsuyo; Farah, Myriam; Jung, Beverly.
Afiliación
  • Kiaii M; St. Paul'S Hospital, 1081 Burrard Street, Vancouver, BC, Canada.
  • Aritomi M; Asahi Kasei Medical Co., Ltd., 1-1-2 Yurakucho, Chiyoda-ku, Tokyo, 100-0006, Japan. aritomi.mb@om.asahi-kasei.co.jp.
  • Nagase M; Asahi Kasei Medical Co., Ltd., 1-1-2 Yurakucho, Chiyoda-ku, Tokyo, 100-0006, Japan.
  • Farah M; St. Paul'S Hospital, 1081 Burrard Street, Vancouver, BC, Canada.
  • Jung B; St. Paul'S Hospital, 1081 Burrard Street, Vancouver, BC, Canada.
J Artif Organs ; 22(4): 307-315, 2019 Dec.
Article en En | MEDLINE | ID: mdl-31254226
ABSTRACT
The vitamin E-bonded polysulfone membrane hemodialyzer (ViE™-21) was evaluated in a clinical study for regulatory submission. Seventeen patients on hemodialysis were treated with conventional high-flux hemodialyzers for 2 weeks (Pre-ViE phase) and switched to the ViE-21 for 36 sessions (ViE phase) followed by an additional 2 weeks on conventional hemodialyzers (Post-ViE phase). Reduction ratios of urea, creatinine, beta-2-microglobulin, albumin, and ultrafiltration coefficients (KUF) were measured once during the Pre-ViE phase and twice during the ViE phase. Moreover, biocompatibility markers [leucocyte count, platelet count, and activated complement factor (C3a) levels] were evaluated pre-dialysis, 15 min after initiation, and post-dialysis. During the study, type and number of adverse events (AEs), and device malfunctions were recorded. ViE-21 reduction ratios and KUF were not noticeably different than those of conventional hemodialyzers. Fluctuations of leucocyte counts and C3a concentrations were similar using ViE-21 and conventional hemodialyzers; however, the platelet count fluctuation was lower in ViE-21 sessions. The frequency of episodes of hypotension occurring during the ViE phase was lower than that occurring during the Pre- and Post-ViE phases. In conclusion, this study provided performance and safety data of the ViE-21 for regulatory application. The data suggest that vitamin E-bonded hemodialyzers are beneficial in lowering platelet activation and frequency of intradialytic hypotension. Larger randomized controlled trials are needed to confirm these findings.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Vitamina E / Diálisis Renal / Fallo Renal Crónico Tipo de estudio: Clinical_trials / Observational_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Artif Organs Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2019 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Vitamina E / Diálisis Renal / Fallo Renal Crónico Tipo de estudio: Clinical_trials / Observational_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Artif Organs Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2019 Tipo del documento: Article País de afiliación: Canadá