Can fully iterative reconstruction technique enable routine abdominal CT at less than 1 mSv?
Tabari, Azadeh; Ramandeep, Singh; Khera, Ruhani Doda; Hoi, Yiemeng; Angel, Erin; Kalra, Mannudeep K; Madan, Rachna.
Afiliación
  • Tabari A; MGH Webster Center for Quality and Safety, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Ramandeep S; MGH Webster Center for Quality and Safety, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Khera RD; MGH Webster Center for Quality and Safety, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Hoi Y; Canon Medical Systems USA, Inc., Tustin, California, USA.
  • Angel E; Canon Medical Systems USA, Inc., Tustin, California, USA.
  • Kalra MK; MGH Webster Center for Quality and Safety, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Madan R; Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts, USA.
Eur J Radiol Open ; 6: 225-230, 2019.
Article en En | MEDLINE | ID: mdl-31304196
OBJECTIVE: We assessed the effect of the forward projected model-based reconstruction technique (FIRST) on lesion detection of routine abdomen CT at <1 mSv. MATERIALS AND METHODS: Thirty-seven adult patients gave written informed consent for acquisition of low-dose CT (LDCT) immediately after their clinically-indicated, standard of care dose (SDCT), routine abdomen CT on a 640-slice MDCT (Aquillion One, Canon Medical System). The LDCT series were reconstructed with FIRST (at STD (Standard) and STR (Strong) levels), and SDCT series with filtered back projection (FBP). Two radiologists assessed lesions in LD-FBP and FIRST images followed by SDCT images. Then, SDCT and LDCT were compared for presence of artifacts in a randomized and blinded fashion. Patient demographics, size and radiation dose descriptors (CTDIvol, DLP) were recorded. Descriptive statistics and inter-observer variability were calculated for data analysis. RESULTS: Mean CTDIvol for SDCT and LDCT were 13 ± 4.7 mGy and 2.2 ± 0.8 mGy, respectively. There were 46 true positive lesions detected on SDCT. Radiologists detected 38/46 lesions on LD-FIRST-STD compared to 26/46 lesions on LD-FIRST-STR. The eight lesions (liver and kidney cysts, pancreatic lesions, sub-cm peritoneal lymph node) missed on LD-FIRST-STD were seen in patients with BMI > 25.8 kg/m2. Diagnostic confidence for lesion assessment was optimal in LD-FIRST-STD setting in most patients regardless of their size. The inter-observer agreement (kappa-value) for overall image quality were 0.98 and 0.84 for LD-FIRST-STD and STR levels, respectively. CONCLUSION: FIRST enabled optimal lesion detection in routine abdomen CT at less than 1 mSv radiation dose in patients with body mass less than ≤25.8 kg/m2.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Clinical_trials Idioma: En Revista: Eur J Radiol Open Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Clinical_trials Idioma: En Revista: Eur J Radiol Open Año: 2019 Tipo del documento: Article País de afiliación: Estados Unidos